SECURE HEATER TO FLOOR
NOTE:
Clearance requirements as detailed in “Clearances
and Height Requirements” section of this manual must be
met before securing heater in place.
To prevent movement, the heater must be secured to the
fl oor or hearth.
1. To remove the grate and base assembly, take out two
screws as shown in
Figures 12
and
13
.
INSTALLATION
Figure 12 -
Remove Grate and Base Assembly (VFI33L models)
Figure 13 -
Remove Base Assembly (VFI33C models)
2. Lift grate and base assembly out of the fi rebox.
3. Secure the fi rebox with two anchoring screws (
3
⁄
16
" x 1
1
⁄
2
"
length) supplied with the fi replace system.
Figure 14
NOTE:
If the unit is mounted on carpeting, tile or
combustible material without the hearth, a metal or wooden
base covering the entire width and depth of the base must
be installed.
Figure 14 -
Secure Firebox to Floor or Hearth