VFI33 Vent Free Gas Fireplace System
20307670
17
PILO
T
OF
F
P
IL
O
T
ON
Continued on next page
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
•
Soap and water solution
•
An approved leak testing spray
•
Electronic sniffer
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound
can set off electronic sniffers.
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. Depress piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
LIGHTING PILOT
Pilot Position
Check for gas leaks in each of the following locations:
•
Pipe from the gas supply line connection to the gas valve
•
Burner connections
•
Field made joints / gas shutoff valve
•
Pilot
•
Factory made joints
•
Each joint or connection
•
All joints on valve and control body
LIGHTING PILOT FOR THE FIRST TIME
OPERATING INSTRUCTIONS — MILLIVOLT
WARNING: NEVER use open fl ame
to check for gas leaks.
WARNING: If using a soap and water
solution to test for leaks, DO NOT
spray solution onto control body.
WARNING: The control has an interlock device that does not allow the lighting of the
fi replace up to the moment the safety device of the fl ame has not interrupted the gas
fl ow. After that period of time (when the magnet is closed), it is possible to start the
lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this
operation. Damaged knobs may result in serious injury.