background image

VFI33 Vent Free Gas Fireplace System

20307670

39

IPI BURNER ASSEMBLY

REPLACEMENT PARTS

REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER. 

1

2

3

4

5

6

7

8

9

10

11

12

CONTEMPORARY 
BURNER

TRADITIONAL 

BURNER

REF

DESCRIPTION

QTY

VFI33CNI

VFI33CPI

VFI33LNI

VFI33LPI

1

Cold Climate Switch

1

95E0111

95E0111

95E0111

95E0111

2

On/Off Switch

1

32D0232

32D0232

32D0232

32D0232

3

Gas Valve

1

95E0101

95E0102

95E0101

95E0102

4

Control Box

1

95E0100

95E0100

95E0100

95E0100

5

ODS Module

1

20303179

20303179

20303179

20303179

6

ODS Pilot Assembly

1

26D2529

14D0476

26D2529

14D0476

7

ODS Module Wire

1

20301890

20301890

20301890

20301890

8

Control to ODS Module Wire

1

95E0120

95E0120

95E0120

95E0120

9

A/C Adapter

1

95E0105

95E0105

95E0105

95E0105

10

Burner Injector

1

33D5040

58D0052

33D5040

58D0052

11

Pilot Regulator

1

14D0469

N/A

14D0469

N/A

12

Piezo Wire

1

20303256

20303256

20303256

20303256

ACCESSORIES

Wall Switch Kit

MVWS

Wall Thermostat Kit

WT

Hand Held Remote

RCB, RCBE, RCMT, WMTD, TMSC

Hand Held Thermostat Remote

RCST, RCSTE, RCT, WWTD, TSST

Thermostat Sensor Kit

TS

Rock Wool

81D2011

 

(TRADITIONAL ONLY)

WARNING: 

Failure to position the parts in accordance with these diagrams or failure to 

use only parts specifi cally approved with this appliance may result in property damage 
or personal injury.

Содержание VFI33CNI

Страница 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Страница 2: ...Operating Instructions IPI 21 For Your Safety Read Before Lighting 21 What to Do If You Smell Gas 21 Operating Instructions 21 To Turn Off Gas 21 EcoLogic Control 22 Electrical Wiring Fan 23 Log Plac...

Страница 3: ...away from furniture and draperies 2 Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition 3 Young children should be...

Страница 4: ...d service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 24 Never burn solid fuels in a fireplace where a unvented r...

Страница 5: ...t of oxygen available in the room and shuts the gas log heater off if the oxygen level begins to drop below a satisfactory level The pilot can only be re lit when adequate fresh air is available THERM...

Страница 6: ...To remedy this issue your fireplace has been designed with a cold climate pilot option which when active maintains a warmer temperature inside your firebox to make ignition faster and more efficient O...

Страница 7: ...alled directly on a combustible floor or a raised platform of an appropriate height Do not place fireplace on carpeting vinyl tile or other soft floor coverings It may however be placed on flat wood p...

Страница 8: ...it must be installed If a combustible mantel is installed It must meet the clearance requirements shown in Figure 7 9 Minimum 9 Minimum 42 Minimum Figure 4 Sidewall and Ceiling Minimum Clearances FP27...

Страница 9: ...Resistant Material for Mantel Example A mantel may project from the wall a maximum of 21 2 at minimum of 8 above the opening and a maximum of 12 at a minimum of 26 above the opening 10 12 14 26 8 12 1...

Страница 10: ...frame panel up and out Figure 9 NOTE Fireplace screen must be removed to access log box and to install canopy Figure 10 Remove Fireplace Screen INSTALL CANOPY 1 Remove the fireplace screen as describ...

Страница 11: ...two screws as shown in Figures 12 and 13 INSTALLATION Figure 12 Remove Grate and Base Assembly VFI33L models Figure 13 Remove Base Assembly VFI33C models 2 Lift grate and base assembly out of the fire...

Страница 12: ...solution after completing connection DO NOT USE AN OPEN FLAME Check the gas pressure with the appliance burning and the control set to HIGH Open control access door on either side of unit to find valv...

Страница 13: ...d at the pressure test point Turn captured screw counter clockwise two or three turns and then place tubing to pressure gauge over test point Use test point OUT closest to control knob After taking pr...

Страница 14: ...wire cable 15 feet maximum length 2 At one end of the cable connect both wires to the wall switch or thermostat At the other end connect one wire to TP TH and one wire to TH or connect the wall switc...

Страница 15: ...ch must face forward NOTE Do not place remote in combustion chamber only the remote receiver CHECK SYSTEM OPERATION The millivolt system and individual components may be checked with a millivolt meter...

Страница 16: ...orce or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to inspect the appliance a...

Страница 17: ...Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made joints gas shutoff valve Pilot Factory made joi...

Страница 18: ...than four 4 seconds for the burner to ignite MAIN BURNER SWITCH This switch allows you to turn on and to turn off the main burner without using the gas valve knob is in the ON position to light the m...

Страница 19: ...This fireplace may be used with a wall switch wall mounted thermostat or IPI hand held remote control JUNCTION BOX WIRING 1 This should be done before framing the fireplace Wire the receptacle into an...

Страница 20: ...service Figure 22 IPI System Wiring Diagram IPI SYSTEM WIRING DIAGRAM ELECTRICAL INSTALLATION IPI WALL SWITCH INSTALLATION The wall switch wire connection is located off the wire harness coming out o...

Страница 21: ...nician to inspect the appliance and to replace any part of the control system and any gas control that has been under water FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these inst...

Страница 22: ...ur RED 1 time Trial Lockout One GREEN every 2 seconds until manual reset Flames Loss Lockout One RED GREEN every 2 seconds until manual reset AC Power On GREEN Solid REMOTE FUNCTION OPERATION ICON Fir...

Страница 23: ...en ON Thermostat Control Blower Motor Black Figure 23 VFI Wiring Diagram Electrical power cord plug can be routed to exit the VFI33 on either the left side or the right side Remove cord protector from...

Страница 24: ...of right side of grate into the I shaped slot on front right corner of unit After moving screw head to the bottom of the I slot insert the screw head on the back of the left side of grate into the key...

Страница 25: ...ROCK WOOL PLACEMENT Before installing logs place rock wool in dime size pieces evenly over small burner ports starting in the rear of the burner going towards the front Avoid placing rock wool on slot...

Страница 26: ...ttom of 7 and locating blocks on logs 4 and 5 Figure 32 8 Place right top log 8 onto right rear 3 and right front 2 logs using locator on bottom of right top log Figure 32 Figure 32 Place Right Top Lo...

Страница 27: ...sure log is fully upright and does not tilt forward Slide 1 log ember chunk back to contact right rear log 2 Place front right log 2 on right pin located on burner and right grate bar Figure 34 After...

Страница 28: ...s for a few hours to vent the odor 6 Place top left log 6 on left rear log 4 and left front log 5 using locating grooves on bottom of 6 and locating blocks on logs 4 and 5 Figure 38 7 Place right top...

Страница 29: ...bly and push towards rear as far as possible 3 Place bottom rear left log 3 on pin on left rear of grate assembly and push towards rear as far as possible Log 4 Figure 43 Log 5 6 Place center top log...

Страница 30: ...all yellow flames to ensure there is no impingement with any log If any yellow flame is contacting any log turn off log set and allow to cool Remove all logs and carefully rein stall following log pl...

Страница 31: ...ier from a neighbor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never us...

Страница 32: ...out of the gas piping 7 With the control knob pushed in push in and release the piezo ignitor button to light the pilot 8 Continue pushing the control knob in for a further 60 seconds to prevent the f...

Страница 33: ...y for easy access to the pilot for example logs screens etc 2 Follow appropriate lighting instructions found previously Instead of pushing and releasing the piezo button light a match and hold the fla...

Страница 34: ...orts Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern and log placement for proper operation Verify smooth and responsive ignition of main burner and r...

Страница 35: ...ppliance shuts off during use 1 Not enough fresh air is available for ODS pilot to operate 2 Low line pressure 3 ODS pilot is partially clogged 4 Defective Thermopile 5 Restrictions in incoming air fl...

Страница 36: ...burner orifice 2 Replace burner 3 Replace gas regulator Logs appear to smoke after initial operation 1 Vapors from paint or curing process of logs 2 Vapors or smoke continue after heater is run with d...

Страница 37: ...546 3 Lower Control Panel 1 20306484 4 Left Firebrick 1 20307263 5 Center Firebrick 1 20307264 6 Right Firebrick 1 20307262 SURROUND 7 33 x 43 Small Black Surround 1 VFICFSS 7 36 x 50 Large Black Surr...

Страница 38: ...14D0503 14D0503 3 ODS Pilot Assembly 1 14D0473 14D0477 14D0473 14D0477 4 Piezo Wire 1 00K0632 00K0632 00K0632 00K0632 5 Control Valve 1 14D0467 14D0468 14D0467 14D0468 6 Pilot Regulator 1 14D0469 N A...

Страница 39: ...14D0476 26D2529 14D0476 7 ODS Module Wire 1 20301890 20301890 20301890 20301890 8 Control to ODS Module Wire 1 95E0120 95E0120 95E0120 95E0120 9 A C Adapter 1 95E0105 95E0105 95E0105 95E0105 10 Burne...

Страница 40: ...81D0084 4 Left Rear Log 1 81D0061 81D0085 5 Left Front Log 1 81D0062 81D0086 6 Middle Left Log 1 81D0063 81D0087 7 Left Top Log 1 81D0064 81D0088 8 Right Top Log 1 81D0065 81D0089 FOR MONESSEN BRANDED...

Страница 41: ...Left Front Log 1 81D0014 81D0038 6 Left Top Log 1 81D0015 81D0039 7 Right Top Log 1 81D0016 81D0040 8 Right Front Log 1 81D0017 81D0041 2 3 4 5 6 7 8 1 BENEATH 7 FOR MAJESTIC BRANDED SYSTEMS REPLACEM...

Страница 42: ...904 4 Bottom front left log 4 1 20305905 5 Center left log 5 1 20305906 6 Center top log 6 1 20305907 7 Top right log 7 1 20305908 FOR MONESSEN OR MAJESTIC BRANDED SYSTEMS REPLACEMENT PARTS REPLACEMEN...

Страница 43: ...installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does n...

Страница 44: ...149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...