6
RFSDV34 Freestanding Direct Vent Gas Stove
10003550
Symptom
1. Battery icon on LCD on transmit-
ter.
. LCD display is blank.
3. LCD display shows “funny” dis-
play.
4. Appliance does not come on.
5. Receiver cannot receive signal.
6. Blower is not on after the stove is
turned on.
Causes
1. Low battery.
1. Wiring/Electrical connections.
. Privacy (DIP) switch setting on
transmitter does not match re-
ceiver.
3. Transmitter measure tem-
perature exceeding 99°F and
shows “HI” on LCD.
4. Distance between the trans-
mitter and receiver is more
than 30 feet.
1. Receiver is installed in an en-
closure.
1. Blower setting is off.
. Blower delay setting is set too
high.
Action
1. Replace batteries. Change the bat-
teries every 6 months.
. Check battery installation or replace
batteries.
3. Press reset button at the back of the
transmitter.
1. Slide the switch to ON, if appliance
comes on, wiring is not the cause.
. If appliance, does not come on,
check wiring connections.
1. Make sure the transmitter and re-
ceiver have the same DIP switch
settings.
1. Move transmitter to a cooler place
and wait until temperature drops be-
low 99°.
1. Make sure the operating distance is
less than 30 feet.
1. Make sure the receiver is not locat-
ed inside too tight of an enclosure.
1. Press FAN key to select desired fan
speed.
. Press and hold Fan key to set de-
sired ON/OFF delays. This is done
in minutes.
Troubleshooting