3
RFSDV34 Freestanding Direct Vent Gas Stove
10003550
Initial Startup
Figure 34
1. After initial power up
or when RESET button
is
pressed, the transmitter
is
reset. The reset button
is
located behind the battery
door of transmitter.
. During system power up
or reset, all features of
the LCD DISPLAY will be
visible. After one second, the LCD will be initialized.
A typical reset display is shown in
Figure 35
. Note the
temperature scale is degree F.
3. Press ON button to select between °C and °F display.
It will exit setting mode automatically after 10 seconds
if no key is pressed. The transmitter will send an OFF
signal after reset.
4. After power up or reset, the transmitter is operating in
manual mode. The room temperature is shown.
Manual Mode
Figure 35
1. Press the ON button once
to
turn on the appliance with
max flame height.
. Press the OFF button
to
decrease flame height.
T h e f i r s t t w o ( )
presses will decrease
flame height to lower
level. The third press will
turn off the fireplace.
3. If the OFF button is held for more than three (3) seconds,
the fireplace will be shut off.
Thermostatic Mode
Figure 36
1. Press the AUTO/FLAME
button to enter the thermo-
static mode.
. In thermostatic mode, press
the ON /
▲
button or OFF
/
▼
button to set the desired
set temperature.
3. Once the setting is com-
pleted, the transmitter will
automatically turn on the
fireplace when the room temperature is below the set
temperature and turn off the fireplace when the room
temperature is above the set temperature within 1
degree.
4. There will be a slight delay in the response of the unit
(on/off) to a temperature. Room temperature is moni-
tored every three (3) minutes.
5. Press AUTO/FLAME button to exit the thermostatic
mode. The transmitter will be in the manual off mode
and the fireplace will be shut off.
Flame Height Setting for Thermostatic Mode
Figure 37
1. Hold AUTO/FLAME button
for five (5) seconds and
one number and flame
icon will appear in LCD
screen.
. Use the ON /
▲
or OFF /
▼
button to set the desired
flame height to 1 (min.)
(medium) or 3 (max.).
3. If there is no input within
three (3) seconds, the new
setting will be transmitted to the receiver. This setting
only affects auto mode operation.
4. The default setting for transmitter is (medium).
3-Speed Blower Control
NOTE: Blower operates with flame on ONLY>
Figure 38
1. Press FAN button once to enter blower speed setup
mode at low speed initially and one of the three blade
icons will display dark-
ened on LCD display.
. Continue to press FAN
button to set the blower
speed you desire.
3. If there is no input within
three (3) seconds, the
new setting will be trans-
mitted to receiver. If
the fireplace is on, the
blower speed will take
effect right away; if the
fireplace is off, the
receiver will remember this setting and blower is still
off.
4. If you continue to press FAN button to the position that
all blades are gone, the FAN icon will disappear and
turn the blower off.
°F
FP2142
initial start up
Fig. 34
Typical Reset
Display
FP14
FP143
°F
FP2143
manual mode
12/08
Fig. 35
Manual mode.
FP2144
thermostat mode
12/08
°F
°F
SET
Fig. 36
Thermostatic
mode.
FP144
FP2147
flame height setting
12/08
Fig. 37
Flame height
setting.
FP147
FP145
°F
FP2145
3 speed fan
12/08
Fig. 38
3 speed blower
control.
The transmitter will operate the remote receiver from 1
foot to a maximum of 30 feet. The distance is reduce
when batteries are low or when the receiver is inside a
metal enclosure.