14
RFSDV34 Freestanding Direct Vent Gas Stove
10003550
If the foundation is recessed, use recess brackets (not
supplied) for securing lower portion of the snorkel. Fasten
brackets to wall first, then secure to snorkel with self drilling
#8 x 1/ sheet metal screws. It will be necessary to extend
vent pipes out as far as protruding wall face. (Fig. 1)
Do not back fill around snorkel. A clearance
of at least 4” (102 mm) must be maintained
between snorkel and the soil.
BG401
Snorkel
2/10/99 djt
Snorkel
Wall Screws
Foundation Recess
Recess Brackets
Watertight Seal
Around Pipe
Sheet Metal
Screws
BG401
Fig. 21
Snorkel installation, recessed foundation.
Vertical Through-the-Roof Applications
This Gas Stove has been approved for:
•
Vertical installations up to 40’ (1 m) in height. Up to a
10’ (3 m) horizontal vent run can be installed within the
vent system using a maximum of two 90° elbows.
•
Up to two 45° elbows may be used within the
horizontal run. For each 45° elbow used on the
horizontal level the maximum horizontal length must be
reduced by 18” (457 mm).
Example: Maximum horizontal length
0 x 45° elbows = 10’ (3 m)
1 x 45° elbows = 8
¹⁄₂
’ (.6 m)
x 45° elbows = 7’ (.1 m)
•
A minimum of an 8’ (.4 m) vertical rise.
•
Two sets of 45° elbows offsets within these vertical
installations. From 0 to a maximum of 8’ (.4 m) of
vent pipe can be used between elbows. (Fig. )
•
7DVCS must be used to support offsets. (Fig. ) This
application will require that you first determine the roof
pitch and use the appropriate starter kit. (Refer to Venting
Components List)
CFM140
Typical vertical through-the-roof application
2/01 sta;
rev. 0602 rjs
Max.
8’
(.4 m)
45°
Max.
8’
(.4 m)
45°
Max. 40’
(1 m)
Typical Straight-up Installation
Typical
Ceiling
Support Ap-
plication
Typical
Roof Support
Application
CFM140
Fig. 22
Vertical through-the-roof installation.
Minimum Height
Above Roof
ST934
minimum height
6/07
Minimum
Roof Pitch
Height
Flat to 7/1
1’0”
Over 7/1 to 8/1
1’6”
Over 8/1 to 8/1
’0”
Over 9/1 to 10/1
’6”
Over 10/1 to 11/1
3’3”
Over 11/1 to 1/1
4’0”
Over 1/1 to 14/1
5’0”
Over 14/1 to 16/1
6’0”
Over 16/1 to 18/1
7’0”
Over 18/1 to 0/1
7’6”
Over 0/1 to 1/1
8’0”
Fig. 23
Minimum height above roof requirements.
ST934