20306741
5
BLDV7 Series Gas Fireplace
PRODUCT FEATURES
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home appr-oved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
PRODUCT SPECIFICATIONS
FP2073
BLDV controls
Off/Pilot/On Knob
Figure 1 -
BLDV7 Series Fireplace
(Millivolt Control shown)
Hi/Lo Knob
On/Off/RS
Switch
Ignitor
FP2073
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local author-
ities having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
GAS PRESSURES
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
GAS SPECIFICATIONS & ORIFICE SIZE
Max. Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
BLDV300NSC7
Nat.
22,000
15,000
2.35 mm
BLDV400NSC7
Nat.
26,000
19,000
2.5 mm
BLDV500NSC7 Nat. 28,000 20,000 #38
BLDV300PSC7
LP
22,000
17,000
1.45 mm
BLDV400PSC7
LP
26,000
21,000
1/16 in.
BLDV500PSC7
LP
27,000
22,000
1.55 mm