20306741
29
BLDV7 Series Gas Fireplace
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Optional
Light
Optional
AUX
Blower (300w Max)
FP2684
BLOTSDVSC fan wiring
Blower (300w Max)
Figure 37 -
BLOTBLDVSC Blower Wiring Diagram
Control Box
Optional AC
Module
NOTE
The black and white wires on the AC box wiring
harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is
important to use the wires marked ‘Blower’ or the
control will not work correctly.
BLOTBLDVSC OPTIONAL BLOWER
The BLOTBLDVSC Blower Kit requires the SCSACM A/C
Module and the TSFSC remote to install and operate this
kit. Refer to blower instructions for installation.
WARNING
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
WARNING
Electrical connections should only be performed by a
qualified licensed electrician. Main power supply must be
turned off before connecting the fan to the main electrical
power supply or performing service.
SIGNATURE COMMAND INSTALLATION
BLACK
BLACK
WHITE
GREEN
BLACK
BLACK
WHITE
Receptacle
Junction
Box
120VAC
Speed Control
FP2685
BLOTSDV blower wiring
Figure 38 -
BLOTSDV Blower Wiring Diagram
Before installing the blower, wire the receptacle into an
electrical circuit. This should be done before framing the
fireplace. Wire with minimum 60° C wire in accordance
with prevailing codes.
BLOTBLDV OPTIONAL BLOWER