14
57D0215
380IDV/490IDV Fireplace Insert
VeNtING INStAllAtION
MANIFOlD ReMOVAl AND INStAllAtION
The manifold is shipped attached to insert. It may be
removed to allow tight installation. Manifold may be loos-
ened and rotated for desired
pipe location.
1. Remove brick liner and
baffle.
2. Remove manifold. Place
manifold in fireplace.
3. Route flex vent through chim-
ney from above.
Figure 10.
Leave an extra 3" (914 mm)
at the top.
FP2629
flex vent
Flex
Vent
Chimney
Manifold
Bracket
Nut
FP2629
Figure 10 -
Place Manifold into Fireplace
FP2630
attach flex vent
Extra 3"
Chimney
Flex
Vent
Manifold
FP2630
Figure 11 -
Attach Flex Vent to Manifold
4. Attach flex vent to
manifold.
Figure 11.
Seal with silicone
and attach with
screws.
FP2631
pull excess vent
Excess
Flex
Vent
Chimney
Slack in
Flex Vent
Manifold
FP2632
Figure 12 -
Pull on Excess Flex Vent
5.Place manifold in
an upright posi-
tion. Pull on excess
vent.
Figure 12.
Temporarily attach
flex vent to top of
chimney. Leave
some extra slack
in flex vent.
FP2632
place insert
Vent
Termination
Chimney
Excess Slack
Take out of Flex
Vent
Manifold
Bracket
Nut
FP2632
Figure 13 -
Slide Insert into Place
Insert
6. Slide insert into place.
Guide the manifold
over the insert until it
is fully in place.
Figure
13
7. Remove any slack from
flex vent. Attach mani-
fold to insert.
Figure
13
8. Remove any excess
slack in flex line. Attach
v e n t t e r m i n a t i o n .
Figure 13
9. Replace baffle and
brick liner.
Содержание 380IDVNV