4.  Never install the insert 

• 

in a recreational vehicle

  where curtains, furniture, clothing, or other flam-

mable objects are less than 36" from the front, top, 

or sides of the insert

  in high traffic areas

  in windy or drafty areas 

5.  This insert reaches high temperatures. Keep children 

and adults away from hot surfaces to avoid burns or 

clothing ignition. Insert will remain hot for a time after 

shutdown. Allow surfaces to cool before touching. 

6.  Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, 

young  children  and  others  may  be  susceptible  to 

accidental contact burns. A physical barrier is recom-

mended if there are at risk individuals in the house. To 

restrict access to a fireplace or stove, install an adjust-

able safety gate to keep toddlers, young children and 

other at risk individuals out of the room and away from 

hot surfaces.  

7.  Do not modify insert under any circumstances. Any 

parts removed for servicing must be replaced prior to 

operating insert. 

8.  Turn insert off and let cool before servicing, installing, 

or repairing. Only a qualified service person should 

install, service, or repair the insert. Have burner system 

inspected annually by a qualified service person. 

9.  You must keep control compartments, burners, and 

circulating air passages clean. More frequent cleaning 

may be needed due to excessive lint and dust. Turn off 

the gas valve and pilot light before cleaning insert. 

10. Have venting system inspected annually by a quali-

fied service person. If needed, have venting system 

cleaned or repaired. Refer to 

Cleaning and Mainte-

nance

, Page 29. 

11.  Keep the area around your insert clear of combustible 

materials, gasoline, and other flammable vapor and liq-

uids. Do not run insert where these are used or stored. 

Do not place items such as clothing or decorations on 

or around insert. 

IMPORtANt SAFety INFORMAtION

This insert is a vented product. This insert must be properly 

installed by a qualified service person. The glass door must 

be properly seated and sealed. If this unit is not properly 

installed by a qualified service person with glass door prop-

erly seated and sealed, combustion leakage can occur. 

cARBON MONOxIDe POISONING:

 Early signs of carbon 

monoxide poisoning are similar to the flu with headaches, 

dizziness  and/or  nausea.  If  you  have  these  signs,  the 

insert may not have been installed properly. Get fresh air at 

once! Have the insert inspected and serviced by a qualified 

service person. Some people are more affected by carbon 

monoxide  than  others. These  include  pregnant  women, 

people with heart or lung disease or anemia, those under 

the influence of alcohol, and those at high altitudes. 
Propane/LP  gas  and  natural  gas  are  both  odorless. An 

odor-making agent is added to each of these gases. The 

odor helps you detect a gas leak. However, the odor added 

to these gases can fade. Gas may be present even though 

no odor exists.
Make certain you read and understand all warnings. Keep 

this manual for reference. It is your guide to safe and proper 

operation of this insert.
1.  This  appliance  is  only  for  use  with  the  type  of  gas 

indicated  on  the  rating  plate. This  appliance  is  not 

convertible for use with other gases unless a certified 

kit is used. 

2.  For propane/LP insert, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply 

tank(s) outdoors. To prevent performance problems, 

do  not  use  propane/LP  fuel  tank  of  less  than  100 

lbs. capacity. 

3.  If you smell gas

  shut off gas supply.

• 

do not try to light any appliance.

• 

do not touch any electrical switch; do not use any 

phone in your building .

• 

immediately call your gas supplier from a neigh-

bor’s  phone.  Follow  the  gas  supplier’s  instruc-

tions.

INStAlleR

Please leave these instructions with the appliance.

OWNeR

Please retain these instructions for future reference.

• 

Read this owner’s manual carefully and completely before trying to assemble, operate, 

or service this fireplace. 

• 

Any change to this fireplace or its controls can be dangerous.

• 

Improper installation or use of this fireplace can cause serious injury or death from 

fire, burns, explosions, electrical shock and carbon monoxide poisoning.

W

ARNING

Содержание 380IDVNV

Страница 1: ...anual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home...

Страница 2: ...ation 22 Door and Filigree Installation 24 Operating Instructions 25 What To Do If You Smell Gas 25 Lighting Pilot for the First Time 25 Lighting Pilot 26 Lighting Burner 27 To Turn Off Gas 27 Adjust...

Страница 3: ...ified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door prop erly seated and sealed combustion leaka...

Страница 4: ...se appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTE...

Страница 5: ...ocal codes Aftermarket Completion of sale not for purpose of resale from the manufacturer HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up t...

Страница 6: ...zn 500 mm E 10C 264 mm 11Z x 292 mm F 29Z x 749 mm 33 838 mm G 15 zn 395 mm 17Z x 445 mm H 20C v 527 mm 22C v 578 mm I 21B 549 mm 23ZC zn 605 mm J 22C v 578 mm 24ZB zn 633 mm K 16B zn 414 mm 18B zn 4...

Страница 7: ...s CodeANSI Z233 1 NFPA54 current edition the Uniform Mechanical Code current edi tion and Local Building Codes for specific installation requirements IMPORTANT Your direct vent insert was designed to...

Страница 8: ...in this manual HEARTH REQUIREMENTS The insert must be installed on a noncombustible hearth extending a minimum of 12 from the fireplace opening local codes may require a larger hearth The hearth must...

Страница 9: ...e of the large amount of heat this appliance pro duces when determining a location FP2624 insert placement Figure 5 Insert Placement For tight fits you may remove the manifold Refer to Remove the Mani...

Страница 10: ...your room is well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during...

Страница 11: ...nting system Installation of any component part not manufactured or approved by Vermont Castings Group Installation other than permitted by these instruc tions WARNING Failure to follow these instruct...

Страница 12: ...just air shutter properly may lead to improper combustion which can create a safety hazard Consult your dealer or installer if you suspect an improperly adjusted air shutter WARNING High Temp Silicone...

Страница 13: ...ero clearance fireplace FP2627 inlet exhaust reline Exhaust Inlet Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 9 Inl...

Страница 14: ...h Flex Vent to Manifold 4 Attach flex vent to manifold Figure 11 Seal with silicone and attach with screws FP2631 pull excess vent Excess Flex Vent Chimney Slack in Flex Vent Manifold FP2632 Figure 12...

Страница 15: ...ULATOR External Regual tor Vent Pointing Down 100 gal min Propane LP Supply Tank FP1930 Figure 14 External Regulator with Vent Pointing Down Propane LP Only CAUTION Use only new black iron or steel pi...

Страница 16: ...Check your building codes for any special requirements for locating equipment shutoff valve to inserts Apply pipe joint sealant lightly to threads This will prevent excess sealant from going into pipe...

Страница 17: ...sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clo...

Страница 18: ...l connections should only be per formed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in complian...

Страница 19: ...ver add additional logs or embellishments such as pine cones or vermiculite to the heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to...

Страница 20: ...l left base log Figure 20 LG766 rockwool Left Front Log 2 LG768 Figure 20 6 Align holes in bottom of right base log 3 with two 2 to the right of rear log Figure 21 7 Align hole in bottom left center l...

Страница 21: ...5 Right Center Log 5 LG771 Figure 23 9 Place one end of right top log 6 on cutout of right base log Align opposite end on right center log Figure 24 10 Lay top Y log 7 across rear log and center logs...

Страница 22: ...4 attach eyebrow Surround Screws Eyebrow Figure 26 KT1334 KT1335 install surround Insert Hooks KT1335 Figure 27 3 Install glass frame cover by aligning four 4 hooks on back of glass frame cover with t...

Страница 23: ...634 install beveled surround Beveled Surround Screws FP2634 Installing On Off switch 1 After installing surround disconnect the on off switch from wires leading from heater 2 Insert switch into hole i...

Страница 24: ...shoulder screws located on the bottom of the surround Figure 34 NOTICE Remove all fingerprints from facing with a 50 50 vinegar and water solution before lighting the heater Any fingerprints left on...

Страница 25: ...ed service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to...

Страница 26: ...1 and 2 Lighting pilot Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made joints gas shutoff...

Страница 27: ...urner Depress and turn the knob counterclockwise to the ON position It will take less than four 4 seconds for the burner to ignite Pilot position Depress and turn knob to pilot position to keep burner...

Страница 28: ...ion at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 36 To decrease air m...

Страница 29: ...2 Carefully remove broken glass 3 Slide new glass frame back down onto insert and fasten two latches Figure 38 FP2639 remove glass Latches FP2639 Figure 38 Glass Frame Removal Glass Frame WARNING HOT...

Страница 30: ...film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass no more than two or three times a season Use a mild glas...

Страница 31: ...ely before cleaning Logs reach high tempera tures Make sure clearances to combustibles leave enough room for maintenance and service Carefully reassemble and reseal insert properly after any cleaning...

Страница 32: ...f exces sive sooting is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Figure 42 5 Replace log set and rock wool per instructions on Pages 19 21 R...

Страница 33: ...connections are good but there is no spark 2 Check for spark arcing from the elec trode to pilot Adjust and retighten 1 Check for proper connection of ther mocouple to rear of valve 2 Bleed line Cont...

Страница 34: ...1D0203 White Hi Temp FP1946 blower wiring diagram Blower Snap Disc Variable Speed Control Hi Temp Hi Temp OFF ON 1 2 110 115 V AC Blower Plug Black White Green Blower Motor FP1946 NOTE Unplug power co...

Страница 35: ...57D0215 380IDV 490IDV Fireplace Insert 35 REPLACEMENT PARTS 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 570016 IDV parts...

Страница 36: ...0163 48D0163 48D0163 48D0163 17 Hex Bushing 1 2 x 3 8 1 57D0007 57D0007 57D0007 57D0007 18 Nipple 3 8 x 1 50 1 P1012 P1012 P1012 P1012 19 Disk Bracket 1 26D3320 26D3320 26D3320 26D3320 20 Rear Log 1 1...

Страница 37: ...57D0215 380IDV 490IDV Fireplace Insert 37...

Страница 38: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 39: ...Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner...

Страница 40: ...ochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency 380IDVNV 69 6 380IDVPV 66 2 490IDVNV 69 8...

Отзывы: