380IDV/490IDV Fireplace Insert
VeNtING INStAllAtION
AltItuDe cONSIDeRAtIONS
This heater has been tested at altitudes ranging from sea
level to 4,500 feet (1,370 m). In this testing, heater with
standard orifice burns correctly with just an air shutter
adjustment. If you need to resize orifice for use at high
altitude, contact your dealer.
Failure to adjust air shutter properly may
lead to improper combustion which can
create a safety hazard. consult your dealer
or installer if you suspect an improperly
adjusted air shutter.
W
ARNING
High-Temp
Silicone
High-Temp
Silicone
FP2626
connect exhaust pipe
380 Series - 3" and 3"
UL 1777 Gas Liner
490 Series - 4" and 3"
UL 1777 Gas LIner
Apply high-temperature silicone to
lines on both ends and secure with
two (2) screws
Figure 8 -
Connecting Vent Pipe to Heater
FP2626
Inlet
Exhaust
(Centered on unit)
Termination Kit
380 Series - AI3TK33A, HEDV321212, HEDVRT
490 Series - AI42TK43A