background image

6

57D0215

380IDV/490IDV Fireplace Insert

INSeRt DIMeNSIONS

Figure 2 - 

IDV Fireplace Insert Dimensions

C

D

E

M

L

G

F

B

A

B

A

H

K

I

J

570016
IDV dims

 

Ref. 

380IDV 

490IDV

 

22

C\v

(578 mm) 

24

C\v

"  (629 mm)

 

30

C\zn

"  (767 mm) 

33

ZZ\zn

"  (856 mm)

 

27

B\,

(702 mm) 

31

Z\,

"  (791 mm)

 

17

M\zn

"  (443 mm) 

19

ZZ\zn

"  (500 mm)

 

10

C\,

(264 mm) 

11

Z\x

"  (292 mm)

 

29

Z\x

(749 mm) 

33" 

(838 mm) 

 

15

>\zn

"  (395 mm) 

17

Z\x

"  (445 mm)

 

20

C\v

(527 mm) 

22

C\v

"  (578 mm)

 

21

B\,

(549 mm) 

23

ZC\zn

"  (605 mm)

 

22

C\v

(578 mm) 

24

ZB\zn

"  (633 mm)

 

16

B\zn

"  (414 mm) 

18

B\zn

"  (465 mm)

 

8

XC\cx

"  (221 mm) 

9

XM\cx

"  (250 mm)

 

4

Z\x

(114 mm) 

5

B\,

(143 mm)

 

Ref. 

380IDV 

490IDV

  A 

28"  (711 mm) 

31"  (787 mm)

  B 

21"  (533 mm) 

23"  (584 mm)

  C 

21"  (533 mm) 

23"  (584 mm)

  D 

21"  (533 mm) 

23"  (584 mm)

  E 

16"  (406 mm) 

18"  (457 mm)

Figure 3 - 

IDV Fireplace Insert Opening Dimensions

C

A

D

B

FP2530
hearth dims

E

Содержание 380IDVNV

Страница 1: ...anual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home...

Страница 2: ...ation 22 Door and Filigree Installation 24 Operating Instructions 25 What To Do If You Smell Gas 25 Lighting Pilot for the First Time 25 Lighting Pilot 26 Lighting Burner 27 To Turn Off Gas 27 Adjust...

Страница 3: ...ified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door prop erly seated and sealed combustion leaka...

Страница 4: ...se appliances have been tested by CSA and found to comply with the established standards for DIRECT VENT GAS FIREPLACE HEATERS in the USA and Canada as follows LISTED VENTED GAS FIREPLACE HEATER TESTE...

Страница 5: ...ocal codes Aftermarket Completion of sale not for purpose of resale from the manufacturer HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified without deration for elevations up t...

Страница 6: ...zn 500 mm E 10C 264 mm 11Z x 292 mm F 29Z x 749 mm 33 838 mm G 15 zn 395 mm 17Z x 445 mm H 20C v 527 mm 22C v 578 mm I 21B 549 mm 23ZC zn 605 mm J 22C v 578 mm 24ZB zn 633 mm K 16B zn 414 mm 18B zn 4...

Страница 7: ...s CodeANSI Z233 1 NFPA54 current edition the Uniform Mechanical Code current edi tion and Local Building Codes for specific installation requirements IMPORTANT Your direct vent insert was designed to...

Страница 8: ...in this manual HEARTH REQUIREMENTS The insert must be installed on a noncombustible hearth extending a minimum of 12 from the fireplace opening local codes may require a larger hearth The hearth must...

Страница 9: ...e of the large amount of heat this appliance pro duces when determining a location FP2624 insert placement Figure 5 Insert Placement For tight fits you may remove the manifold Refer to Remove the Mani...

Страница 10: ...your room is well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during...

Страница 11: ...nting system Installation of any component part not manufactured or approved by Vermont Castings Group Installation other than permitted by these instruc tions WARNING Failure to follow these instruct...

Страница 12: ...just air shutter properly may lead to improper combustion which can create a safety hazard Consult your dealer or installer if you suspect an improperly adjusted air shutter WARNING High Temp Silicone...

Страница 13: ...ero clearance fireplace FP2627 inlet exhaust reline Exhaust Inlet Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box Figure 9 Inl...

Страница 14: ...h Flex Vent to Manifold 4 Attach flex vent to manifold Figure 11 Seal with silicone and attach with screws FP2631 pull excess vent Excess Flex Vent Chimney Slack in Flex Vent Manifold FP2632 Figure 12...

Страница 15: ...ULATOR External Regual tor Vent Pointing Down 100 gal min Propane LP Supply Tank FP1930 Figure 14 External Regulator with Vent Pointing Down Propane LP Only CAUTION Use only new black iron or steel pi...

Страница 16: ...Check your building codes for any special requirements for locating equipment shutoff valve to inserts Apply pipe joint sealant lightly to threads This will prevent excess sealant from going into pipe...

Страница 17: ...sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clo...

Страница 18: ...l connections should only be per formed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing service All wiring shall be in complian...

Страница 19: ...ver add additional logs or embellishments such as pine cones or vermiculite to the heater Only use the logs supplied with the unit Failure to position the parts in accordance with diagrams below or to...

Страница 20: ...l left base log Figure 20 LG766 rockwool Left Front Log 2 LG768 Figure 20 6 Align holes in bottom of right base log 3 with two 2 to the right of rear log Figure 21 7 Align hole in bottom left center l...

Страница 21: ...5 Right Center Log 5 LG771 Figure 23 9 Place one end of right top log 6 on cutout of right base log Align opposite end on right center log Figure 24 10 Lay top Y log 7 across rear log and center logs...

Страница 22: ...4 attach eyebrow Surround Screws Eyebrow Figure 26 KT1334 KT1335 install surround Insert Hooks KT1335 Figure 27 3 Install glass frame cover by aligning four 4 hooks on back of glass frame cover with t...

Страница 23: ...634 install beveled surround Beveled Surround Screws FP2634 Installing On Off switch 1 After installing surround disconnect the on off switch from wires leading from heater 2 Insert switch into hole i...

Страница 24: ...shoulder screws located on the bottom of the surround Figure 34 NOTICE Remove all fingerprints from facing with a 50 50 vinegar and water solution before lighting the heater Any fingerprints left on...

Страница 25: ...ed service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to...

Страница 26: ...1 and 2 Lighting pilot Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made joints gas shutoff...

Страница 27: ...urner Depress and turn the knob counterclockwise to the ON position It will take less than four 4 seconds for the burner to ignite Pilot position Depress and turn knob to pilot position to keep burner...

Страница 28: ...ion at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 36 To decrease air m...

Страница 29: ...2 Carefully remove broken glass 3 Slide new glass frame back down onto insert and fasten two latches Figure 38 FP2639 remove glass Latches FP2639 Figure 38 Glass Frame Removal Glass Frame WARNING HOT...

Страница 30: ...film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass no more than two or three times a season Use a mild glas...

Страница 31: ...ely before cleaning Logs reach high tempera tures Make sure clearances to combustibles leave enough room for maintenance and service Carefully reassemble and reseal insert properly after any cleaning...

Страница 32: ...f exces sive sooting is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Figure 42 5 Replace log set and rock wool per instructions on Pages 19 21 R...

Страница 33: ...connections are good but there is no spark 2 Check for spark arcing from the elec trode to pilot Adjust and retighten 1 Check for proper connection of ther mocouple to rear of valve 2 Bleed line Cont...

Страница 34: ...1D0203 White Hi Temp FP1946 blower wiring diagram Blower Snap Disc Variable Speed Control Hi Temp Hi Temp OFF ON 1 2 110 115 V AC Blower Plug Black White Green Blower Motor FP1946 NOTE Unplug power co...

Страница 35: ...57D0215 380IDV 490IDV Fireplace Insert 35 REPLACEMENT PARTS 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 570016 IDV parts...

Страница 36: ...0163 48D0163 48D0163 48D0163 17 Hex Bushing 1 2 x 3 8 1 57D0007 57D0007 57D0007 57D0007 18 Nipple 3 8 x 1 50 1 P1012 P1012 P1012 P1012 19 Disk Bracket 1 26D3320 26D3320 26D3320 26D3320 20 Rear Log 1 1...

Страница 37: ...57D0215 380IDV 490IDV Fireplace Insert 37...

Страница 38: ...ly with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed Massachusetts Residents Only Please r...

Страница 39: ...Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner...

Страница 40: ...ochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency 380IDVNV 69 6 380IDVPV 66 2 490IDVNV 69 8...

Отзывы: