16
57D0215
380IDV/490IDV Fireplace Insert
INSeRt INStAllAtION
Only persons licensed to work with gas
piping may make the necessary gas con-
nections to this appliance.
A manual shut-off valve is factory installed
upstream of the appliance. union tee and
plugged 1/8" NPt pressure tapping point
should be installed upstream of the appli-
ance.
Figure 15
NOte : the gas line connection may be made using
1/2" rigid tubing or an approved flex connector. Since
some municipalities have additional local codes it
is always best to consult your local authorities and
the current edition of the National Fuel Gas code
ANSI.Z223.1, NFPA54. In canada cSA-B149 (1 or 2)
Installation code.
A listed manual shutoff is factory installed upstream of
appliance. Union tee and plugged 1/8" NPT pressure tap-
ping point should be installed upstream of the appliance.
Figure 15
IMPORtANt:
The main gas valve is for turning on or
shutting off the gas to the insert.
Check your building codes for any special requirements for
locating equipment shutoff valve to inserts.
Apply pipe joint sealant lightly to threads. This will prevent
excess sealant from going into pipe. Excess sealant in pipe
could result in clogged burner system valves.
Natural Gas
From Gas Meter
(4.5" w.c. to 10.5" w.c. Pressure)
Propane/lP
From External Regulator
(11" w.c. to 13" w.c. Pressure)
3" Minimum
FP1931
gas connection
9/08
Approved Flexible
Gas Line Supplied
with Appliance
Tee Joint
Pipe Nipple
Cap
Figure 15 -
Gas Connection
W
ARNING
c
A
ut
ION
use pipe joint sealant that is resistant to
liquid petroleum (lP) gas.
c
A
ut
ION
We recommend that you install a sediment trap/drip leg in
supply line as shown in
Figure 15
. Locate sediment trap/drip
leg where it is within reach for cleaning. Install in piping
system between fuel supply and burner system. Locate
sediment trap/drip leg where trapped matter is not likely to
freeze. A sediment trap traps moisture and contaminants.
This keeps them from going into the burner system gas con-
trols. If sediment trap/drip leg is not installed or is installed
wrong, burner system may not run properly.
Содержание 380IDVNV