CDVZ Series Direct Vent Gas Fireplace
20014621
Top of Unit to Ceiling ..................................36” (914 mm)
Front of Unit to Combustibles .....................36” (914 mm)
Appliance
Top .............................................................0” (0 mm)
Bottom ........................................................0” (0 mm)
Side ............................................................0” (0 mm)
Back ...........................................................0” (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides .................................1” (25 mm)
Flex Vent......................................................7/8” (22 mm)
NOTE: Hood must be permanently installed with three
(3) sheet metal screws supplied in fireplace. (Refer to
hood installation in this manual.)
Mantels
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This also
applies to the distance between the mantel leg (if fitted)
and the fireplace.
For the correct mounting height and widths refer to Figs.
4a and 4b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram
and chart.
Noncombustible mantels and legs may be installed at any
height and width around the appliance.
When using paint or lacquer to finish the mantel, such paint or
lacquer must be heat resistant to prevent discoloration.
Clearance to Combustibles
CFM170
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01 sta
Black
Surround
Face
CFM170
DV Builder Front
View
O
N
M
L
K
Side of
Combustion Chamber
CFM164a
Mantel
Mantel Leg FromSide
Ref.
Leg Depth
Ref.
of Comb. Opening
F
10” (254 mm)
K
11
¹⁄₂
” (292 mm)
G
8” (203 mm)
L
9
¹⁄₂
” (241 mm)
H
6” (152 mm)
M
7
¹⁄₂
” (191 mm)
I
4” (101 mm)
N
5
¹⁄₂
” (140 mm)
J
2” (51 mm)
O
3
¹⁄₂
” (89 mm)
Fig. 4b
Combustible mantel leg minimum installation.
A) Flat on wall
B) Cross corner
C) **Island
D) Room divider
E) Flat on wall corner
F) Chase installation
Y) Refer to “Clearance to Combustibles” Section
NOTE:
(Fig. 3)
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20’ (6 m) with a minimum vertical of 4’ (122 cm). See
details in Venting Section.
Locating Your Fireplace
Y
E
A
B
C
D
F
Y
B
X
LU584-R
Locating unit
2/23/01 sta
X
LU584-R
Fig. 3
Locate gas fireplace.
CFM146
A
B
C
D
E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01 sta
Hood
Top of Combustion
Chamber
Mantel Chart
Mantel Shelf or
Mantel from Top of
Ref. Breast Plate Depth Ref. Combustion Chamber
V
10” (254 mm)
A
17” (432 mm)
W
8” (203 mm)
B
15” (381 mm)
X
6” (152 mm)
C
13” (330 mm)
Y
4” (101 mm)
D
11” (279 mm)
Z
2” (51 mm)
E
9” (229 mm)
Fig. 4a
Combustible mantel minimum installation.
Standoff
Finish Wall
3/4” (19 mm) Scribe
Moulding for use
with Vermont Cast-
ings Group Cabinets
3/4” (19 mm) Scribe
Moulding for use with
Vermont Castings Group
Cabinets