15
CDVZ Series Direct Vent Gas Fireplace
20014621
FP1005
Side View Vent Termination
1/25/00 djt
22”
(559 mm)
CL
Finished
Wall
Secure with Screw
Vent Termination
Firestop
FP1005a
Fig. 19
Side view of final unit location.
Rear Wall Vent Installations -
45° Flex Vent Pipe
Using Kit 7TCD45KT
NOTE:
The corner placement dimensions on Page 5,
Figure 1 of the manual must be adhered to! Figures 20 &
21 show general installations. Refer to instructions below
for a detailed description of installation.
1. Determine where the termination is to be installed.
Locate the center of the hole 29
Z\x
” (749 mm) off
the floor. (Fig. 20)
NOTE:
The location of the termination hole must be
adhered to!
2. Install the firestop as shown on Page 14.
3. Remove the flex vent and extend the flex vent out to
its longest length.
4. Bend the tab on the back of the fireplace up. (Fig.
18)
FP1473
corner flex install
4/04 djt
C
L
to Floor
29
56O
”
(749 mm)
Termination
Flex Section
Appliance
Collars
FP1473
Fig. 20
Grasp the vent pipe close to the collar and bend to 45°
angle. Do not exceed 45°.
5. Insert the collar on the flex vent that has the twist lock
embosses on it onto the collar of the fireplace. Twist
the collar to “lock it” onto the fireplace. Run a screw
through the tab and into the collar to secure the collar
onto the fireplace.
6. Bend the flex pipe up 90° as close to the fireplace as
possible. (Fig. 21)
7. Slide the fireplace partially into the corner and, while
holding the vertical portion of the flex vent pipe, grab
the exposed end collar and bend it down to the height
of the opening in the wall.
8. While pushing the unit in place, slide the collar through
the firestop.
NOTE:
It may be necessary to trim some
material off of the collar. The collar is made long to
accommodate brick finished houses. (Fig. 23)
9. Secure the collar in place by running a screw through
the tab in the firestop and through the collar.
10. Slide the termination into the collar and secure with
the 4 screws provided. (Fig. 23)