RFS INSTALLATION INSTRUCTIONS
VERIZON HYBRIFLEX CABLE| Revision 1 | APRIL 2019
Visit
for the most current product specifications
Page 31 of 33
Hybriflex into OVP’s
At the base of the OVP boxes there are cable glands that provide
weatherproofing for the enclosure.
The following steps will show how to install the
Hybrid cable properly.
Remove compression nut. (
Figure 1
)
Remove center insert from cable gland. Slide compression nut
over the cable breakout (no insert require). Be careful not to
damage the fiber connectors. (
Figure 2,3
)
Carefully feed fiber and power conductors into the OVP box
(Keep ESD bag intact) and tighten the compression nut.
(Figure
4, 5, 6,7)
Refer to the OVP’s Manual for wiring and fiber spooling detail.
Torque:
44 in-lbs
Note: Should the process of installing cables loosen the gland, then the inner nut needs to be
retightened (66 in-lb [7.5 N-m]) to maintain the environmental seal of the enclosure.
Figure 3