RFS INSTALLATION INSTRUCTIONS
VERIZON HYBRIFLEX CABLE| Revision 1 | APRIL 2019
Visit
for the most current product specifications
Page 33 of 33
Tower/Box Mount OVP’s
1)
Strip the outer jacket 3.0 inches back
Fig. 1
2)
Twist the outer copper strands together
Fig. 2
3)
Strip the jacket off the red insulated conductor 1/2 of an
inch
Fig. 3
4)
Insert Low Inductance wire into splitter insulator
Fig 4
5)
Feed the Low inductance wires into the Raycap box and
connect to the power connectors.
6)
Connect wires according to the Verizon Wireless
established color guide. Recommended starting with lower
bottom left OVP of the box (OVP).
Fig. 5, 5a
7)
END
Figure 1
3.0”
Figure 2
Figure 5, 12 OVP’s
Figure 3
½”
Figure 4
Figure 5a, 6 OVP’s
Start Here
3.0”