40
Monitor ISM/xL™ Hardware Guide
22-0375 rev1.1
1 2
1 2
1 2
3
2
1
4
3
2
1
4
3
2
1
12
12
12
3
2
1
3
2
1
4
5
6
3
2
1
4
5
3
2
1
4
5
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
13
2
13
2
1
1
4
3
2
5
1
2
13
2
3
3 1
3
1
1
3
2
2
2
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
13
2
13
2
1
1
4
3
2
5
1
2
13
2
3
3 1
3
1
1
3
2
2
2
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
13
2
13
2
1
1
4
3
2
5
1
2
13
2
3
3 1
3
1
1
3
2
2
2
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
3
2
13
2
13
2
1
1
4
3
2
5
1
2
13
2
3
3 1
3
1
1
3
2
2
2
2
1 2
1 2
1 2
3
2
1
4
3
2
1
4
3
2
1
12
12
12
3
2
1
3
2
1
4
5
6
3
2
1
4
5
3
2
1
4
5
DA
T
A
I
N
DA
T
A
0
DA
T
A
1
)
(+( )
DA
T
A
I
N
DA
T
A
0
DA
T
A
1
)
(+( )
DA
T
A
I
N
DA
T
A
0
DA
T
A
1
)
(+( )
DA
T
A
I
N
DA
T
A
0
DA
T
A
1
)
(+( )
E
lev
1/
2 D
a
ta
0
El
ev
1/
2
D
a
ta
I
n
El
ev
1/
2 D
a
ta
1
GND
)
( +
()
El
ev
1/
2 D
a
ta
I
n
E
lev1
/2 D
a
ta
1
E
le
v
1/
2 D
a
ta
0
AC AC (
-
) (+) (
-
) (+)
12VDC
Battery
16V40VA
TXMR
Power Supply
(P/N 110-5560)
GND
GND
GND
GND
)
(+( )
)
(+( )
Ground Lug
GND
Use all 4 quad
cable wires
WATERPIPE
GROUND
Connect common waterpipe
ground to cabinet GND lug.
DI
N
D0
D1
DI
N
D0
D1
Main Terminal Block
To Relay Boards in Expansion Cabinet
See Notes below.
Interconnect with all expansion
cabinet power supply negatives.
Starter cabinet power supply negative.
To Relay Boards in Expansion Cabinet
Elevator Relay Board
P/N 650-9035
Elevator Relay Board
P/N 650-9035
Elevator Relay Board
P/N 650-9035
Elevator Relay Board
P/N 650-9035
Elevator Isolator Board
P/N 641-9036
Elevator Isolator Board
P/N 641-9036
Cabinet Frame
Tamper Switch
SEE NOTES
)
( +
()
J
5
J
4
J
3
J
2
J
1
J
6
J
7
J
8
J
5
J
4
J
3
J
2
J
1
J
6
J
7
J
8
J
5
J
4
J
3
J
2
J
1
J
6
J
7
J
8
J
5
J
4
J
3
J
2
J
1
J
6
J
7
J
8
ELEVATOR ISOLATOR and RELAY BOARDS in STARTER KIT CABINET
Spare
GND
Lug.
Move as
required.
Spare
GND Lug.
Move as
required.
Shipped as pre-wired for 2 elevator cabs, 16 floors each (when 3 more relay boards and 1 additional
isolator board are added). To change for a single elevator cab, 32 floors maximum (when 3 more
relay boards are added) add jumper wires as shown by dashed lines at Main Terminal Block. See
Packages and Products list, page 10.
Proceed from these connections to more relay boards in add-on Expansion Cabinets.
Always interconnect power supply ground with power supply ground in additional expansion
boxes.
Use pre-wired Main Terminal Block to connect 2 separate isolator board elevator systems.
NOTES:
CABINET FRAME TAMPER SWITCH Each Starter, Expansion cabinet tamper switch must be in
series (normally closed) with the 2 Elevator Module controller tamper connection. Use shielded 4
conductor P/N 120-3401. Connect at tamper terminals on Main Terminal Block. Terminate shield
at ground lug in Elevator Module cabinet. Interconnect shield between additional cabinets but do
not terminate any where else.
1
st
Elevator
2nd Elevator
Address 0
Address 0
Address 1
Address 1
4 Relay Boards
Maximum
(+)
( )
(+) ( )
(+)
( )
( )
(+)
(+)
( )
Power the
Elevator Module
side of the
Elevator Isolator
Boards with a
separate power
supply (P/N 110-
5560).
Содержание ISM/xL
Страница 1: ...Monitor ISM xL Hardware Guiderev1 1...
Страница 2: ......
Страница 5: ...22 0375 rev1 1 Monitor ISM xL Hardware Guide 1 Part 1 Monitor ISM System Hardware...
Страница 50: ...46 Monitor ISM xL Hardware Guide 22 0375 rev1 1...
Страница 64: ......
Страница 65: ......
Страница 66: ...N3459...