22-0375 rev1.1
Monitor ISM/xL™ Hardware Guide
31
•
When selecting SMR, the status of each concentrator will display and pressing the LCD keypad left or right arrow
keys will display each concentrator’s status. Pressing
Next
will return to the main Smart/Vigil module menu.
•
The concentrator may state that it’s
OK
.
Tmpr
= conc. tamper.
Tmpr Au_ERR
= the concentrator is in tamper
and has had an authentication error (concentrator substitution e.g. conc. dis/reconnected).
PTmpr
= the
Smart/Vigil module itself is in tamper and the concentrator is OK.
Smart/Vigil Module Test and Diagnostics
•
Using Service user ID/PIN, enter the Test menu and select App. Select SMA for Smart/Vigil module.
•
HSC
is NOT USED.
Printer Option (Smart Module ONLY)
•
Pressing
PRN
will allow you to control and do tests on the printer.
•
Pressing
Ctrl
will give you the options to
Strt
: start the printer,
Cncl
: cancel pending messages,
Plg
the entire log.
•
Pressing
L/B
will do a printer port loop back test the same as the HSC loop back test on the HSC/Printer
module (discussed later in this manual) to test printer hardware integrity.
Smart/Vigil Concentrator Tests
•
Pressing SMR from the SMA menu will display
Alog
for point analog. Pressing it will display the condition of a
Smart/Vigil input using different values. The Smart/Vigil input point numbers can be scrolled using the LCD
keypad left or right arrow keys. Values indicate: “
018
” = normal, “
001
” = tamper, “
032
” = in alarm. These readings
may vary but still be within these ranges.
•
Pressing
Vault Tst
will test all seismics connected to any concentrators through out the system. The display will
change to “
Testing Vault Concentrators
” and stay on for 1 second. The test occurs in 15 to 20 seconds
afterwards.
•
After this delay is finished, go to the Analog screen again. Scroll the various points until the ones that may have
had a test fail display. They will display with an “
F
” (failed).
•
Pressing
TFAL
(test fail) will display the concentrator number and seismic that failed. E.g.
Conc: 001
(concentrator #1),
F-X-F-X-X
(seismics 2 and 3 failed the test).
Содержание ISM/xL