21 | Page
Version
00
© Verder Liquids B.V
Ds500, Ds500+ Operating manual
Original instructions (en)
• Display
Backlight dim - Adjust the time before the backlight dims.
Display auto off - Adjust the time before the display
switches off.
• Date/Time
Adjust the date and time.
•
Wifi
Once enabled, press to go to wifi settings screen.
• Automatic restart
Unit will automatically restart if the motor was running at
the time of power loss.
10.3.2.5 Date/Time
From this screen the date and time can be adjusted:
Figure 25. - Date / Time Settings
Battery backup ensures that minimal date and time adjustments
are required.
10.3.2.6
Wifi
This screen allows the operator to connect to a wifi access
point:
Figure 26. -
Wifi Setup
Note:
wifi needs to be enabled from the pump settings screen.
Symbol
Description
Press to start scanning for available
wireless networks
Wireless SSID selection buttons
Press to enter the password to connect to
the selected SSID.
Press to connect to the selected SSID.
Figure 27. -
Popup keyboard for wifi password entry
10.3.2.7 Unable to connect / signal strength
Under normal conditions (no connection issues) the screen will
report the
signal strength
; the greater the value, the stronger
the signal will be (-50 will be stronger than -100).
If there is an issue with the connection,
unable to connect
will
be shown in place of signal strength.
10.3.3 Cartridge information
This screen provides information about the cartridge and
facilitates replacement:
Figure 28. - Cartridge Information
Press to stop the unit so that the cartridge can be
replaced.
A popup will appear to warn the operator that the pump must
be in a stopped state. Press accept to stop the pump:
With the pump stopped, the motor is disengaged and the
cartridge can now be removed:
WARNING
Always use PPE (eye protection and clothing) if hazardous
fluids have been pumped.
1. Drain the system.
2. Safely release any pressure in the pipework.
3. Release the port sealing nuts and remove the tubes whilst
ensuring that fluid does not spill out.
4. Release the cartridge lock.
5.
Rotate the cartridge 20° CW and remove.
6. Safely and responsibly dispose of the cartridge. Check
your local disposal guidelines, particularly when hazardous