Vantage 5000
1.4v-09.2019
45 | Page
8.3.2 Memory Dose
Before using the Memory Dose, the user must check that the
Job File has been activated as per
Figure 73.
This function does
not work in ‘Manual’ mode.
Memory Dose operates as follows:
u
Select the flow rate, tube size, tube material and ‘Dose/
Batch’ mode as per
Figure 73.
u
Once the
‘Dose/Batch’
has been selected, select ‘Dose’
Mode as per
Figure 74.
u
Select the dose value. A keypad will appear as per
Figure 75
.
u
Set the value to zero (do not press “
p
”) and press the
START button, the pump will start to dispense. When the
required quantity of product has been dispensed, press the
STOP button and the Memory Dose Value will be displayed
as per
Figure 76
:
u
Press “
p
”, the value of Memory Dose will be displayed in
the dose value box as per
Figure 77
.
Press “x” will abandon the Memory Dose.
The user can start another Memory Dose by following the
steps listed previously.
Memory dosing is saved in the job that was activated to request
memory dosing in the first place. The saved values are only
transferable to another job file if you perform a job ‘copy’ action.
Figure 75 Select the Dose Value
Figure 77 Memory Dose
Figure 73 Select the Dose /Batch Mode
Figure 74 Select the Dose Mode
Figure 76 Memory Dose Displayed
Note