5.2.3 Installing the Tube Element
[
Ensure the Vantage 5000 pump is turned
off using the ON/OFF switch on the back
of the pump, if not, the rotor cannot be
turned by hand.
1. Open the pump door.
2. Slide the tube element into the pump
head.
3. Rotate the rotor assembly using the
vertical guide rollers in a counter-clock-
wise direction.
4. Place the tube behind the vertical guide
rollers and continue to turn the rotor
assembly in counter-clockwise direction.
5.
When performed correctly the main
rollers will compress the tube element.
6.
Slide the lower tube element housing into
the pump head.
7. Once the tube is in place, close the pump
door before switching on the power sup-
ply.
Figure 6.2 Installing the Tube Element
1
6
3
4
5
2
u
Isolate power supply from the pump before opening the
pump head.
u
Make sure the tube is compatible with the rotor assembly.
u
Before using a new tube assembly, make sure the pump is
run in the counter-clockwise direction for 1 minute.
DANGER
CAUTION