Expansion and contraction noises during the heating and cooling cycle are normal. Here is how to prevent
smoke flow reversal: position air intake lever to maximum, slowly open the fireplace doors before lighting
the kindling, make a torch by lighting rolled up newspaper and hold it out to the smoke chamber until your
feel the chimney begin to draw.
A properly installed Fireplace should never smoke. If it does, it will probably be for one of the following
reasons:
1. The chimney’s outdoor installation is defective or incorrect, creating draught reversal problems and,
consequently, making it difficult to start a fire.
2. The chimney was not adequately preheated. Remember that the hotter the fireplace, the better the
chimney draws smoke.
3. The fireplace doors or the air intake damper were closed too quickly. Adequate air supply is essential to
sustaining combustion.
4. If the room is too airtight or negative pressure has built in the house and there is no outside air intake,
air supply to the fireplace will be lower than usual. Temporarily open a window near the fireplace to
increase air supply.
5. Any type of fan (range hood or bathroom exhaust fan) that draws air outside can create negative
pressure. Shut off the fan and/or open a window near the fireplace to solve this problem.
6. Wet wood smokes more than dry wood. The damper the wood, the less heat it generates and the more
creosote it produces. If the wood being burned is very damp, inspect the chimney every month it is
used.
7. Make sure the chimney is reasonably clean and unobstructed.
8. Check whether the chimney is the recommended height: minimum of 3’ (914 mm) from the roof joint.
If not, add more lengths of flue. This will improve draw and reduce the fireplace’s tendency to smoke.
9. Fireplaces with chimneys abutting an unfinished outside wall often tend to smoke and are difficult to
light. To prevent these problems, open a window near the fireplace and preheat the chimney by
holding a newspaper torch in the smoke chamber (upper part of the combustion chamber). Wait long
enough to establish effective draw, then light the fire.
10. Always remove excess ashes before lighting a fire. Maintaining a 1” (2.5 mm) thickness of ashes
optimizes combustion and maximizes fire duration.
11. Use only dry wood, i.e. wood that has dried for one year (15% to 20% humidity). Very dry wood will
burn very well, but will generate a great deal of heat and will not last.
Содержание ME150
Страница 5: ...ME150 Installation and Operation Manual 5 1 2 Views with measurements ...
Страница 9: ...ME150 Installation and Operation Manual 9 ...
Страница 13: ...ME150 Installation and Operation Manual 13 18 457 21mm 18 457 2mm 16 406 4mm 16 406 4mm 18 457 2mm ...
Страница 15: ...ME150 Installation and Operation Manual 15 Direct installation Exterior offset installation ...
Страница 21: ...ME150 Installation and Operation Manual 21 Chimney Enclosure Canada and U S Chimney Enclosure Canada only ...
Страница 24: ...24 ME150 Installation and Operation Manual ...
Страница 28: ...28 ME150 Installation and Operation Manual PL60004 ...
Страница 30: ...30 ME150 Installation and Operation Manual 7 1 Exploded view for replacement parts ...