SECTION 3
Initial Setup
5
to use the machine. Once this chip is depleted, the machine will notify you, and no
more cycles will be allowed, until a new C-H Chip is installed.
NOTE: THE VMI HYBRID
WILL NOT OPERATE WITHOUT A C-H CHIP.
Power Cord:
The VMI Hybrid unit comes with a power cord based on the region that
the machine is designated for. This power cord needs to be installed into the Power
Inlet located on back of the unit. Then proceed to take the other end of the power
cord and plug it into a wall outlet.
Prepping Consumables:
Before any
discs can be run in the VMI Hybrid
it is essential to prep the Buffing
Solution and the Water lines.
WARNING: FAILURE TO PREP THE
BUFFING SOLUTION & WATER LINES
WILL CAUSE DAMAGE TO BOTH THE
DISC AND THE PADS!
The following
is a step by step sequence for
prepping the consumables:
Turn on power to the unit by
1.
pressing the ON/OFF switch,
located on the back of the unit,
to the ON position.
Upon powering up, the TOP
2.
COVER will automatically open.
Have a small container or
3.
receptacle ready in order to
catch the Buffing Solution and
the Water that will come from
the Tube Nozzles during the
prepping process.
Located on the front of the VMI Hybrid is the User Keypad. On the User Keypad,
4.
located on the right hand side, are two buttons labeled “C” for Buffing Solution and
“W” for Water. Located below these two buttons, is the label entitled “Prep Line”.
To activate the prepping process, simply press either the “C” or the “W” button.
5.
Note: Both lines can be prepped at the same time, but it is recommended that
one line be prepped at a time. Once the Buffing Solution and the Water comes
out of the designated Tube Nozzles and there is no more air left in the lines,
press either the “C” button to stop the Buffing Solution flow or press the “W”
button to stop the water flow.
FAILURE TO USE CONSUMABLES DESIGNED FOR THIS UNIT WILL CAUSE DAMAGE TO BOTH UNIT AND
DISC THEREBY VOIDING YOUR WARRANTY. FOR AUTHORIzED DISTRIBUTORS VISIT WWW.VENMILL.COM.