MA-SE-DCT3-01-02 Manual Doge CT3 eng rev2 

 

   Rev.4 Pagina 8 di 17 

HOW TO PROCEED TO REPLACE BATTERY:  

Arming of the system, disarming of the system, within 60 seconds since the cover opening. 
Make the necessary steps: battery replacement etc.., 24 hours z

one and anti-tamper not active, infinitive time available. 

 

Close the cover, arm and disarm the system. 

24 hours zone and anti-tamper are re-activated

.  

 
HOW TO PROCEED for complete WALK TEST: 

Arm the system, disarm the system, open the cover within 60 seconds.  
Make the necessary steps: replace battery, check cabling etc.  

The 24 hours zone and the anti-tamper are not active, infinitive time available.  
The sound of the horn is attenuated for about 1 hour. 

Arm the system. Check if all detectors trigger off an alarm, check if the telephone dialer sends out the call, check that the indoor 
siren sounds. 
Close the cover  
Arm and disarm the system. 

The 24 hours zone and the anti-tamper are re-activated. High intensity sound.

 

 
HOW TO PROCEED TO CHECK the 24 hours lines and the lines balancing: 

The LED LD1 visualizes the tamper open according to the priority shown in the chart “LED Tamper”  so, if the LED flashes 5 times, it 
means that the only opened tamper is the one on the bottom of the sounder or the cover so the zones are correctly balanced and 
the 24 hours line is closed.  

 

 

USE 

The following behaviours have to be taken into consideration: 

 

If  a  line  goes  in  alarm,  in  order  for  it  to  be  able  to  trigger  off  a  new  one  at  the  end  of  the  alarm  cycle,  it  must  re-balance 
(condition of non-alarm) and unbalance again. 

 

This behaviour is valid for normal alarms, for the 24 hours line and for the Reed tamper.  

 

A delayed line still unbalanced at the end of the output time causes an alarm without waiting for the input time.   

 

ARMING  

Putting  the  key  in  position  ON  or  pressing  the  pushbutton  A  (total)  or  B  (partial)  of  the  remote  control,  the  anti-intrusion  zones 
activate, the zone 1 will become operative after the output time. At the same time, the indication of armed system (three flashes) or 
of output time (flashes during the whole output time) switches on.  
The output STI (system status) activates fix at 0V in case of total arming or intermitting in case of partial arming.   

 
INPUT/OUTPUT TIME  

After arming the control panel, the output time starts, at the same time the indication of armed system switches on and the zones 2 
and 3 are operative.   
Once this time is finished, the zone 1 becomes operative. At armed system, the opening of an immediate zone causes the general 
alarm whilst the opening of a delayed zone activates the general alarm after the input time if the system is not disarmed meanwhile.  
The duration of the input and output time is set by DIP3. 
 

DISARMING  

Putting the mechanical key in OFF position or pressing the pushbutton A or B of the remote control, the anti-intrusion lines de-
activate and the indication of active system switches off.  

 

PARTIAL ARMING  

Further to the total arming (all lines active), the control panel can also be armed in partial mode 

PART, 

with line 3 not active. This 

type of arming allows to maintain protected some zones and to move freely in the zone 3.  
In order to arm the system in partial mode, press the pushbutton B of the remote control, the lamp will flash to show arming. The 
Led of system status lights up flashing to show partial arming.   

 

Behaviour: 

1)

 

System armed: active system-status output. The Led of the lamp flash three times. 
a)

 

Zones 1, 2, 3 or tamper in alarm: active alarm output. Sound of the sounder for the time-lapse of DIP 1. Flashing of the Led 

for  infinitive  time  showing  the  first  zone  in  alarm.  The  number  of  flashes  shows  the  zone  in  alarm.  If  all  Led  flash 
progressively it’s a 24 hours alarm. 

b)

 

System disarming by key or remote control, LED switching off  

2)

 

Arming with zone 1 open: if the zone is set as delayed,  the lamp will flash quickly during the output time   

3)

 

Anomalies such as: Zone 1 open, low battery, mains absence, problems on battery or horn make the lamp flash quickly in any 
status of the system. 

4)

 

Max number of alarms per zone: when the DIP is set on OFF, any zone causes max 4 alarms in 24 hours. Once expired the 24 
hours from first alarm, zones are re-enabled to trigger off alarme. Even in case of disarming  and the arming, the lines are re-
enables and the alarm counting starts again. The 24 hours has no limit in alarms number.    

Содержание DOGE CT3

Страница 1: ...er charged against UV Protection against wall tampering and cover opening Protection against polarity inversion Discharged battery causes block of the horn and quick flashing further to block of the i...

Страница 2: ...e central Led with 1 pulse and then pause ON PARTIAL The central Led flash 3 times and then flash of the central Led with 2 pulses and then pause ON DISARMED All Led switch on for 5 seconds and then s...

Страница 3: ...ND ANOMALIES RED LED LD1 1 Speaker interruption 1 FLASH 2 Mains missing with immediate indication tension of the supply unit less than 11 9V 2 FLASHES 3 Battery not connected 3 FLASHES 4 Battery spoil...

Страница 4: ...of partially armed system 0V in case of disarmed system Can be connected to the Led of system status of Minidoge or Minimurano 12V Output with 13 V tension always available protected by auto restorabl...

Страница 5: ...line and FARO DT detector tamper STANDARD DETEC DOGE CT Pict 7 Connection balanced line and STANDARD AM detector tamper STANDARD DETECTOR DOGE CT Pict 5 Connection with NC line and tamper STANDARD de...

Страница 6: ...on the picture 10 Memorize the first pushbutton of the remote control on OUT3 and the second on OUT4 the open collector outputs of the Vela receiver Program the two outputs as mono stable Two pushbutt...

Страница 7: ...3meters OFF default Sirena Standard 1 250 2 645 103 ON NFC48265 1430 1585 107 INSTALLATION SERVICE AND TEST WALK TEST The anti tamper circuit is blocked right after supplying of the board and for abo...

Страница 8: ...time switches on The output STI system status activates fix at 0V in case of total arming or intermitting in case of partial arming INPUT OUTPUT TIME After arming the control panel the output time st...

Страница 9: ...e of anomaly during arming and disarming operations it will flash quickly As soon as the anomaly disappear flash returns to normal speed about 1 flash per second LED Anomalies on board it shows anomal...

Страница 10: ...minutes can be set to 8 minutes Frequency limits See chart 12 Sounds Acoustic power See chart 12 Sounds Duration of the Led flash 1 000 000 flash minimum Conditions of humidity from 20 to 100 of humi...

Страница 11: ...nt LEDs flash for 1 minute Does the tamper LED make 5 flashes Put zone 2 in alarm status Do the front LEDs make 2 flashes and then a pause AND does the loudspeaker sound at low volume Push A button of...

Страница 12: ...ck if the sounder is correctly powered through the power supply connector Open the sounder cover and count the number of flashes as indicated in chart 3 Solve the anomaly then turn the sounder off and...

Страница 13: ...ceiver to DOGE CT3 using the dedicated cable Picture 7 Give power supply to DOGE CT3 using a battery or a power supply unit Do the 2 LEDs of the receiver make a GREEN flash Push the button of the rece...

Страница 14: ...6 relay 1 contact common 7 relay 2 contact n o Led 1 red when activated 8 relay 2 contact common 9 output 3 Open Collector Led 2 green when activated 10 output 4 Open Collector Led 2 red when activate...

Страница 15: ...uency 433 92 MHz APPLICATION NOTES RELAY OUTPUT CHANGE To modify relay outputs from normally open N O to normally closed N C Cut the route relevant to desired output as in below figure N B After cutti...

Страница 16: ...rn to operating mode is signaled by LED switching off Exemple 3 removal of transmitter from memory Push the button 5 times at first pressure LED 1 switches on green at second pressure LED 1 switches o...

Страница 17: ...pressure push the button of transmitter that you want remove NOTE Maximum number of acquirable transmitters 50 Activation of output Activation of outputs is signalled by switching on of relevant LED L...