background image

MA-SE-DCT3-01-02 Manual Doge CT3 eng rev2 

 

   Rev.4 Pagina 4 di 17 

 
CONNECTIONS: 
TERMINALS (chart 4): 
 

MAL 

M1 

Alarm memory output; on in alarm and alarm memory. Tamper output, 24 hours alarm.  
Open collector, 0V = alarm  

ANM 

M2 

Output for anomaly output and mains missing after 3 hours. Open Collector, ground = 
anomaly 

STI 

M3 

Output for system status, positive push pull = system armed  

+12V 

M4 

Supplying , with auto-restorable fuse for detectors and devices  

GND 

M5 

Ground 

A_C 

M6 

Dry-contacts alarm relay, Common  

AAC 

M7 

Dry-contacts alarm relay,  NC or NO contact, selection via jumper  

Z1 

M8 

Zone 1 – Connect to ground  (or with terminal resistance) if not used  

Z2 

M9 

Zone 2 – Connect to ground  (or with terminal resistance) if not used 

Z3 

M10 

Zone 3 – Connect to ground  (or with terminal resistance) if not used 

24h 

M11 

 24h line – Connect to ground if not used  

KEY 

M12 

Key of total arming:     Free = total arming, 0V = off. 

GND 

M13 

ground 

 

+MAL

          Open collector output for alarm memory. Activated to 0V in case of alarm, tamper alarm and alarm for balanced line in 

short-circuit. Active until cancellation of the alarm memory as set by dip7. Can be used for Led switching-on, relay or to activate a 
telephone dialer.  

 

ANM           

Anomaly open collector output, 0V in case of anomaly – see chart 3. Activated after 3 hours of missing mains. Can be 

used for Led switching on, relay or activation f a telephone dialer.  

 

STI            

Push-pull output for system status, 12V in case of totally armed system, intermitting in case of partially armed system, 0V 

in case of disarmed system. Can be connected to the Led of system status of Minidoge or  Minimurano.  

 

+12V          

Output with 13 V tension always available, protected by auto-restorable fuse. Can be used for supplying detectors and 

bells. 

 

GND          

Ground terminal for connecting negative of all peripherals or detectors.

 

 

A_C           

Dry-contacts alarm relay, Common Terminal.

 

 

AAC           

Dry-contacts alarm relay, terminal settable as normally open or normally closed selecting the jumper J7. Active in Alarm, 

Tamper Alarm and balanced-line in short-circuit for the duration set by DIP1

  

 

Z1:            

Zone of NC detection or single balancing, immediate or delayed. One or more series input-detectors are connected to this 

zone. If set as single balancing, connect a 5600 Ohm resistance in series to the cable

 

 

Z2, Z3:      

Zones of NC detection or single balancing, immediate. One or more input detectors are connected in series. If set as single 

balancing, connect a 5600 Ohm resistance in series to the cable  

 

 

24h:            

NC immediate “auto-protection” detection line. All NC contacts of the auto-protection devices of the detectors, alarm 

indicators and additional units if any, have to be connected to this terminal.  The status variation of one device triggers off the alarm 
immediately with both armed or disarmed system.  

 

KEY:          

Key line. A NC-to-ground line has to be connected to this terminal. When the line is closed the system is disarmed, when it 

is  open  the  system  is  totally  armed.  Connect  towards  the  ground  when  you  wish  to  have  the  system  re-activated  in  “disarmed” 
mode after a long mains missing

 

 

Note: the zones and the 24 hours line, if not used, must be connected to the ground.  

Содержание DOGE CT3

Страница 1: ...er charged against UV Protection against wall tampering and cover opening Protection against polarity inversion Discharged battery causes block of the horn and quick flashing further to block of the i...

Страница 2: ...e central Led with 1 pulse and then pause ON PARTIAL The central Led flash 3 times and then flash of the central Led with 2 pulses and then pause ON DISARMED All Led switch on for 5 seconds and then s...

Страница 3: ...ND ANOMALIES RED LED LD1 1 Speaker interruption 1 FLASH 2 Mains missing with immediate indication tension of the supply unit less than 11 9V 2 FLASHES 3 Battery not connected 3 FLASHES 4 Battery spoil...

Страница 4: ...of partially armed system 0V in case of disarmed system Can be connected to the Led of system status of Minidoge or Minimurano 12V Output with 13 V tension always available protected by auto restorabl...

Страница 5: ...line and FARO DT detector tamper STANDARD DETEC DOGE CT Pict 7 Connection balanced line and STANDARD AM detector tamper STANDARD DETECTOR DOGE CT Pict 5 Connection with NC line and tamper STANDARD de...

Страница 6: ...on the picture 10 Memorize the first pushbutton of the remote control on OUT3 and the second on OUT4 the open collector outputs of the Vela receiver Program the two outputs as mono stable Two pushbutt...

Страница 7: ...3meters OFF default Sirena Standard 1 250 2 645 103 ON NFC48265 1430 1585 107 INSTALLATION SERVICE AND TEST WALK TEST The anti tamper circuit is blocked right after supplying of the board and for abo...

Страница 8: ...time switches on The output STI system status activates fix at 0V in case of total arming or intermitting in case of partial arming INPUT OUTPUT TIME After arming the control panel the output time st...

Страница 9: ...e of anomaly during arming and disarming operations it will flash quickly As soon as the anomaly disappear flash returns to normal speed about 1 flash per second LED Anomalies on board it shows anomal...

Страница 10: ...minutes can be set to 8 minutes Frequency limits See chart 12 Sounds Acoustic power See chart 12 Sounds Duration of the Led flash 1 000 000 flash minimum Conditions of humidity from 20 to 100 of humi...

Страница 11: ...nt LEDs flash for 1 minute Does the tamper LED make 5 flashes Put zone 2 in alarm status Do the front LEDs make 2 flashes and then a pause AND does the loudspeaker sound at low volume Push A button of...

Страница 12: ...ck if the sounder is correctly powered through the power supply connector Open the sounder cover and count the number of flashes as indicated in chart 3 Solve the anomaly then turn the sounder off and...

Страница 13: ...ceiver to DOGE CT3 using the dedicated cable Picture 7 Give power supply to DOGE CT3 using a battery or a power supply unit Do the 2 LEDs of the receiver make a GREEN flash Push the button of the rece...

Страница 14: ...6 relay 1 contact common 7 relay 2 contact n o Led 1 red when activated 8 relay 2 contact common 9 output 3 Open Collector Led 2 green when activated 10 output 4 Open Collector Led 2 red when activate...

Страница 15: ...uency 433 92 MHz APPLICATION NOTES RELAY OUTPUT CHANGE To modify relay outputs from normally open N O to normally closed N C Cut the route relevant to desired output as in below figure N B After cutti...

Страница 16: ...rn to operating mode is signaled by LED switching off Exemple 3 removal of transmitter from memory Push the button 5 times at first pressure LED 1 switches on green at second pressure LED 1 switches o...

Страница 17: ...pressure push the button of transmitter that you want remove NOTE Maximum number of acquirable transmitters 50 Activation of output Activation of outputs is signalled by switching on of relevant LED L...

Отзывы: