Programming Manual
GLASSFRONT VENDING MACHINES
Rev. 1.12
MODELLS: G-DRINK SVE GF6 / GF9 – DR6 / DR9
Page 24 of 42
“C6” + “C7”
PARAMETERS ARE USED TO DETERMINE UP TO 16 COINS TO BE ACCEPTED.
C6 = coins 1 to 8
C7 = coins 9 to 16
Coin 1 is assumed to be the smallest coin, and coin 16 the highest in value.
Each coin has a binary value as:
C6: coin 1
=
1
C7:
coin 9
=
1
coin 2
=
2
coin 10
=
2
coin 3
=
4
coin 11
=
4
coin 4
=
8
coin 12
=
8
coin 5
=
16
coin 13
=
16
coin 6
=
32
coin 14
=
32
coin 7
=
64
coin 15
=
64
coin 8
=
128
coin 16
=
128
EXAMPLE: If you want to accept coin 1 – 2 – 3 – 4 –13 – 15 you must add the
correspondent values:
C6 = 1 + 2 + 4 + 8 = 15
C7 = 16 + 64 = 80
“C8” + “C9”
PARAMETERS ARE USED TO DETERMINE COINS TO BE ACCEPTED WHEN THE
VMC IS IN LOW CHANGE CONDITION.
The values of these submenus are calculated in the same way as “C6” + “C7” submenu.
"C10" RESET TO THE FACTORY SETTING ( DEFAULT VALUES )
Be careful when using this option as you loose all configuration parameters on the
machine and reset all the counters (also the total counter), you also loose the
configuration of the vending trays, therefore it is necessary to make an auto configuration
(see “STOS” menu).
C10 = 18 Reset value
Put value option on the ConFY "C10" submenu and press button 4 to confirm.
Turn off the machine: Press and keep pressed the button on the board and turn on the
machine and wait until the end of initialisation of the board (when you read message
"RESET" on the display). Release the button on the board.
Now you have to reprogram all parameters.