Programming Manual
GLASSFRONT VENDING MACHINES
Rev. 1.12
MODELLS: G-DRINK SVE GF6 / GF9 – DR6 / DR9
Page 28 of 42
DAILY VEND INHIBITED PERIOD (EXTENDED MENU)
It is used to inhibit the vend on certain trays, for up to 6 periods each day.
If ENTER button is activated at the "VDSTP" prompt the VMC will enter the daily vend
inhibit period control routine with the follow submenu:
-
“ENB X ” Used to enable (X=1) or disable (X=0) the inhibited period function,
-
“START1” Set the start time (HH mm) of the first inhibited period of the day
-
“STOP1” Set the STOP time (HH mm) of the first inhibited period of the day
-
“START2” Set the start time (HH mm) of the second inhibited period of the day
-
“STOP2” Set the STOP time (HH mm) of the second inhibited period of the day
-
“START3” Set the start time (HH mm) of the third inhibited period of the day
-
“STOP3” Set the STOP time (HH mm) of the third inhibited period of the day
-
“START4” Set the start time (HH mm) of the fourth inhibited period of the day
-
“STOP4” Set the STOP time (HH mm) of the fourth inhibited period of the day
-
“START5” Set the start time (HH mm) of the fifth inhibited period of the day
-
“STOP5” Set the STOP time (HH mm) of the fifth inhibited period of the day
-
“START6” Set the start time (HH mm) of the 6th inhibited period of the day
-
“STOP6” Set the STOP time (HH mm) of the 6th inhibited period of the day
-
“TRAY”
Choose the tray to be inhibited
-
“LIT X”
1 to turn off the light during inhibit period, 0 to leave the light on
If a customer wants to purchase from an inhibited selection the message
“NO VEND UNTIL hh:mm” is displayed.