background image

 
Programming Manual 

 

 

 

GLASSFRONT VENDING MACHINES

 

 

Rev. 1.12 

MODELLS: G-DRINK SVE GF6 / GF9 – DR6 / DR9 

Page 30 of 42 

 

 

2.3   MENU  DIAGRAM 

 

MAIN 

MENU 

1 st SUB 

MENU 

2 nd SUB 

MENU 

3 rd SUB 

MENU 

4 th SUB 

MENU 

DESCRIPTION 

ERROR 
ROUTINE 

 

 

 

 

Error routine 

 

NONE 

 

 

 

No errors exits 

 

LIFT 

 

 

 

Lift mechanism summary error 

 

 

ERRXX 

 

 

See corresponding error 

 

CTRL 

 

 

 

Control system summary error 

 

 

DS 

 

 

Door switch 

 

 

RAN 

 

 

RAM check sum of service mode settings 

 

 

ACLO 

 

 

AC supply low 

 

 

SF 

 

 

Scaling factor incompatibility 

 

SEL 

 

 

 

Selection switch summary error 

 

 

SLXX 

 

 

Selection switch error in switch XX (01 - 12) 

 

CHAr 

 

 

 

Changer summary error 

 

 

CC 

 

 

Changer communication error 

 

 

TS 

 

 

Tube sense error 

 

 

IC 

 

 

Changer inlet chute blocked 

 

 

TJXX 

 

 

Tube pay out jam in coin type XX 

 

 

CRCH 

 

 

Changer ROM check sum 

 

 

EE 

 

 

Excessive escrow attempts 

 

 

NJ 

 

 

Coin jam 

 

 

LA 

 

 

Low acceptance rate 

 

 

DIS 

 

 

Disconnected acceptor 

 

 

ROUT 

 

 

Coin routing error 

 

BUAL 

 

 

 

Bill validator summary error 

 

 

BC 

 

 

Bill validator communication error 

 

 

BFUL 

 

 

Bill validator stacker full 

 

 

BILL 

 

 

Defective bill validator motor 

 

 

BJ 

 

 

Bill validator jammed 

 

 

BRCH 

 

 

Bill validator ROM check sum error 

 

 

BOPn 

 

 

Bill validator stacker is open or out of position 

 

 

BS 

 

 

Bill validator sensor error 

 

CRDR 

 

 

 

Card reader summary error 

 

 

CRC 

 

 

Card reader communication error 

 

 

CRXY 

 

 

Card reader non-transient error; code X, sub-code Y 

 

DRUM 

 

 

 

Drum summary error 

 

 

LOCK 

 

 

Fail to lock 

 

 

UNLOCK 

 

 

Fail to unlock 

 

 

OPEN 

 

 

Fail to open 

 

 

CLOSE 

 

 

Fail to close 

 

Содержание G-DRINK DR6

Страница 1: ...Programming Manual GLASSFRONT VENDING MACHINES Rev 1 7 MODELLS G DRINK SVE GF6 GF9 DR6 DR9 Page 0 of 39 GLASSFRONT VENDING MACHINES G DRINK GF6 GF9 DR6 DR9 PROGRAMMING MANUAL...

Страница 2: ...SPECIFICATION FOR ELECTRONIC BOARD SF01 3 1 1 DESCRIPTION OF FUNCTIONS AND FEATURES 4 2 SERVICE MODE 8 2 1 ERROR ROUTINE 9 2 2 PROGRAMMING 12 2 3 MENU DIAGRAM 30 2 4 EVENT TABLE 36 3 DRUM SENSOR ADJUS...

Страница 3: ...tique SILIC 506 F 91946 Courtaboeuf Cedex France Tel 33 0 1 69592500 Fax 33 0 1 69592505 e mail infosvf sandenvendo com SandenVendo Iberia S A Poligono Industrial la Almeda C Sant Ferr n no 92 E 08940...

Страница 4: ...efrigerant system fluorescent tube External slave board placed near main board used to drive 64 vending motor with current control and limitation External slave Optical detector board used to check th...

Страница 5: ...remaining product in the hand bucket LOADING FACILITY In order to allow easier loading of the bottom shelf pushing the delivery flap will move the bucket to the right side pushing the flap again will...

Страница 6: ...be performed by the master until no error is reported see ERROR ROUTINE MDB communication is working correctly VEND DETECTION PROCESS The product is detected when crossing the delivey inner flap by a...

Страница 7: ...Manual GLASSFRONT VENDING MACHINES Rev 1 12 MODELLS G DRINK SVE GF6 GF9 DR6 DR9 Page 6 of 42 DIP Switch MDB EXE For EXE and MDB set to position MDB DIP Switch DEX UCS JACK For Executive set to positi...

Страница 8: ...n button2 Selection Nr 3 O down Decrease or previous programming point by pushing selection button 3 Selection Nr 4 O Enter Store Call or store a programming point by pushing selection button 4 Select...

Страница 9: ...code level Each of these paths is identified by a service code The codes for the various paths are as follows ERROR ROUTINE Error routine TUBES PAYOUT Coin Payout Routine work only MDB TUBES FILLING...

Страница 10: ...ll cycle through all jammed columns If the ENTER button is pressed and held for two seconds during the display of any error code that code will be cleared After clearing VMC will display the next exis...

Страница 11: ...button is activated at the SEL prompt the VMC will display a SLXX message where XX indicates the first selection switch error switch always close Using the UP and DOWN buttons will cycle through all...

Страница 12: ...acker is full a BILL message indicating a defective motor a BJ message indicating that there is a bill jammed in the bill validator a BRCH message indicating a checksum error a BOPN message indicating...

Страница 13: ...ation of the HOME button while a coin value is displayed will return the VMC to the CPO prompt Activation of the HOME button at the CPO prompt returns the VMC to the normal mode door open state TUBE F...

Страница 14: ...LIV To come back to the TEST menu keep pressed the first selection for two seconds DRUM Drum test allows to test and drive separatefunctions LOCK Put the drum in lock postion UNLOCK Put the drum in un...

Страница 15: ...ton to see the money counter submenu C BOX XXXX XXXX total money to cashbox C TUB XXXX XXXX total money to the coinage tube C RET XXXX XXXX total money returned as change C MAN XXXX XXXX total money r...

Страница 16: ...mn Up to GRP10 An symbol near the column means that this one is not installed In multi price mode you can choose different price for each selection using UP and DOWN buttons will cycle through availab...

Страница 17: ...to set the configuration of the machine you have to do it only when you change the control board Choice available is 2 Trays or 3 Trays GF6 2 trays per shelf 6 columns selections GF9 3 trays per shel...

Страница 18: ...displayed without doing an ENTER before will return the VMC to the CON display without saving the displayed configuration Activation of the HOME button returns to unprotected area C1 RESERVED FOR FUTU...

Страница 19: ...l barrier does not detect a product The sold out status is reset when the door switch of the master is actuated C6 0 selection always available C6 1 selection inhibited if empty was detected by the pr...

Страница 20: ...ault If C9 is set to 0 the max coin acceptance maximum selection price C9 1 Multi Vend enabled you can use your change to make another selection or to press the coin return button to get your change I...

Страница 21: ...regarding the C2 Low change equation and C3 minimum coins Tube level If correct change LED is OFF VMC accept coins set in C06 and C07 If correct change LED is ON VMC accept coins set in C08 and C09 AC...

Страница 22: ...credit accepted with cashless systems Maximum credit on cashless systems is managed as follows Revalue If amount of inserted cash actual cashless credit MCARD value Revalue is prohibited If amount of...

Страница 23: ...the empty states assume the exact change state A is the lowest coin value reported in the tubes D is the highest coin value reported in the tubes If tubes are empty according to these equations the C...

Страница 24: ...n vending machine and they are sent to payment system If C2 2 from version 0 10 the machine works in price holding and the line of the price must be programmed on the PRICE menu the machine show the p...

Страница 25: ...D TO DETERMINE COINS TO BE ACCEPTED WHEN THE VMC IS IN LOW CHANGE CONDITION The values of these submenus are calculated in the same way as C6 C7 submenu C10 RESET TO THE FACTORY SETTING DEFAULT VALUES...

Страница 26: ...er TOKEN If enter is pressed at the TOKEN prompt the display show the actual Token value for 1 Bill this value will increment the credit when a special bill is accepted from the validator Use button 2...

Страница 27: ...on the time setting routine with the follow submenu ENbX time status X 0 time disable X 1 time enable press enter to modify X value YEAR press enter show actual year up down modify the value enter to...

Страница 28: ...ge the status of the day 0 not selected 1 selected HOUR press enter to change the stop hour and minute for selected day PAYMENT SYSTEM EXTENDED MENU Pressing button 4 at the PAY S prompt the VMC will...

Страница 29: ...Set the STOP time HH mm of the second inhibited period of the day START3 Set the start time HH mm of the third inhibited period of the day STOP3 Set the STOP time HH mm of the third inhibited period o...

Страница 30: ...inute for selected day STOP Set the end date and time of Age control request DAY Select the days of the week for stop function press enter to cycle through the days press enter to change the status of...

Страница 31: ...hanger communication error TS Tube sense error IC Changer inlet chute blocked TJXX Tube pay out jam in coin type XX CRCH Changer ROM check sum EE Excessive escrow attempts NJ Coin jam LA Low acceptanc...

Страница 32: ...d test 1 to 255 test vends after door closed FAIL Historical counter of lift failures PASS Password entry 10 seconds to enter 4 2 3 1 ENTER CASH COUNTER MONEY Money counter C BOX Money introduced in c...

Страница 33: ...0 not connected 1 connected C 3 Snack slave unit Extra rotation of spiral C 4 Open door message 0 Error 1 counter error C 5 Counter reset mode C 6 Snack slave unit Sold out 0 disable 1 enable C 7 Save...

Страница 34: ...setting yy Edit year 00 99 Y2K MTH Month setting mm Edit month 01 12 DATE Date setting dd Edit date 01 31 HOUR Hour and minute setting hhmm Edit hour 00 24 hhmm Edit minute 00 59 DST Daylight saving t...

Страница 35: ...iod hhmm Hours minutes START2 Start 2 period hhmm Hours minutes STOP2 Stop 2 period hhmm Hours minutes START3 Start 3 period hhmm Hours minutes STOP3 Stop 3 period hhmm Hours minutes START4 Start 4 pe...

Страница 36: ...od DAY Start day setting NONX non tue ued thu Fri sat Sun or ALL ALLX Edit mode 0 1 HOUR Start hour and minute setting hhmm Edit hour 00 24 hhmm Edit minute 00 59 STOP Stop age period DAY Stop day set...

Страница 37: ...S 111216 170957 EA1 EJM_5 111216 170957 EA1 EJE_5 111216 170957 EA2 EGS 7 7 0 EA2 EJM_5 13 13 0 EA2 EJE_5 7 7 0 EA1 EJM_6 111216 170957 EA1 EJE_6 111216 170957 DOOR CLOSE STATUS EA2 EJM_6 7 7 0 EA2 EJ...

Страница 38: ...e previous mode function is cancelled and the timer is reset Instruction for adjusting the photocell 1 Insert the adjusting key A supplied with the photocell in the cut B on the front side 2 Turn the...

Страница 39: ...rs on display with blinking mode for approx 10 seconds If you wish to modify this value while it is blinking press key to increase or press key to decrease it Wait till the controller exits from the p...

Страница 40: ...a forced defrosting and not a programmed one push the Def key for at least 5 seconds and the defrosting cycle will start immediately The 5 colored LEDs situated under the temperature display indicate...

Страница 41: ...down or disconnected E P2 probe for evaporator is down or disconnected The cooling system is controlled by various parameters inserted in the software of the electronic control unit and cannot be modi...

Страница 42: ...ush for more than 1 second SET to visualize the temperature of the set point Increase or decrease the value with UP or DOWN Push SET to confirm the new value Description and function of the CAREL Elec...

Страница 43: ...tion Error in reading of the machine parameters See memorised data errors EF visualized during functioning or activation Error in reading of the working parameters See memorised data errors Ed flashin...

Страница 44: ...n Executive 1 9 02 nd Feb 2011 CONFY C11 used for marketing feature Product hand movement 1 11 May 2012 Modifications from Software Version 1 40 CON C 8 Forced vend rule for cashless systems implement...

Отзывы: