PART 3 - Technical manual
PART 3 - Technical manual
36
37
Electrical parts
Mounting the control unit
The control unit is mounted under the bed, usu-
ally on the bed frame against the headboard but
could also be placed in other locations with free
space.
1. Mount the control unit on the suspension
plate with 4 bolts. There are two different
possible positions.
2. Raise the head end of the bed and choose
an area under the bed for the control unit.
The suspension plate is able to fit bedframes
that are between 1,7 and 4,1 cm wide.
3. Adjust the width of the suspension plate
to suit the current bed frame. Tighten the
suspension plate around the bed frame with
the two fingerscrews.
4. The suspension plate will not fit all kind
of beds. If it is not possible to mount the
suspension plate any where the control unit
must be attached with cable ties.
Connecting the hand control
Connect the hand control to the control unit in
the plug by this symbol
\
on the control
unit
. It is possible to connect an extra hand
control in the plug with this symbol
\ \
.
The hand control should always hang on the
outside of the bed such as on the outside of the
headboard.
The hand control should be connected before
the actuator and power cables are connected.
In case you need to replace a faulty hand
control, begin by unplugging the power cable,
replace the hand control and then reconnect the
power cable to the mains outlet.
Suspension plate for the control unit
The control unit is mounted on the
suspension plate. There are two possible
positions.
Tighten the suspension plate around the
bed frame with the two fingerscrews
The hand control is connected to the control
unit
Connection of cables to control unit
The next step is to connect the actuator cables.
The red side actuator cables have plugs with
green O rings; these are connected to the
green control unit colour codes.
The blue side actuator cables have plugs with
yellow O rings; these are connected to the
yellow control unit colour codes.
The plugs on the blue bar motor cables are
fitted with a blue O ring; these are connected
to the blue control unit colour code.
The plugs on the red bar motor cables are
fitted with a red O ring; these are connected to
the red control unit colour code.
Connection of power cables
The last step is to connect the control unit
power cable to an easily accessible 230V mains
plug. The green diode on the control unit
illuminates when the power is turned on.
Keep all cables away from the floor and the
moving parts of the bed. Once the mounting
is complete, all loose cables must be wrapped
around the control unit mounting fixture cable
guides and secured to prevent them from
falling on the floor or getting pinched by the
moving parts of the bed.
Proper plug location
The green diode on the control unit is
illuminated
All cables must be kept away from the floor
The cables can also be attached to the bedframe with cable ties next to the control
unit.
Attaching the sheets
Please refer to page 22-23 for instructions on how to attach the sheets.