416299
H200
7-15-98
3-10-04A
INST INSTRUCTIONS
VC416/516
III POWER SOURCES
D.
SINGLE ACTING ELECTRIC HYDRAULIC PUMP
See Dwgs. 416315 and 416316.
1. a.
Mount the electric hydraulic power unit in a horizontal position with reservoir breather
upward. Check the hose lengths before mounting the power unit. See Dwgs. 416315
and 416316.
b.
Position the power unit on the truck frame. Check inside of frame channel before marking
hole locations. (wires or brake may be in this area.) Mark mounting holes on the frame
and drill 7/16" dia. throught two places. Mount the power unit to the frame with a
3/16-16 x 1" hex head bolts (grade 5).
2. a.
Install 90° elbow adapter to the pressure port on power unit. Attach end of 5' hose to elbow
fitting in pressure port.
3. a.
Locate and attach the toggle switch and mounting plate to the truck dash or other suitable
location inside cab.
b.
Attach proper color wire from toggle switch to motor solenoid (start switch). Attach other
lead to the toggle switch bottom post and the other end to the linear solenoid on the side of
the power unit. Connect the inline fuse to the center post on the toggle swithc and the other
end to the hot lead under the dash.
c.
Attach the battery cable to the solenoid post indicated Dwgs. 416315 and 416316.
Connect the other end of the battery cable to the positive terminal on the battery.
4. a.
Install the 5' hose to the elbow in the pressure port of the power unit.
b.
To prime the hydraulic system and force most of the air out of the system, obtain a clean
container, place the loose end of the 5' hose into the container. Alternately cycle switch,
one second on, one second off until oil comes out of the 5' hose. Attach the loose end of
the 5' hose to the cylinder base port. If there is not a 90° port on the cylinder, add a 90° st.
elbow to the cylinder baseport, then attache the hose to the elbow.
c.
Fasten the 7' hose to the rod end of the cylinder. If the cylinder doesn't have a 90° port, add
a 90° st. elbow to the rod end cylinder port, then attach the hose to the elbow.
d.
Connect the other end of the 7' hose to the elbow fitting on the return port of the power unit.
MANUFACTURING, INC.
Содержание VC 416
Страница 1: ......
Страница 3: ...516911 R MANUFACTURING INC CINCINNATI OHIO...
Страница 6: ......
Страница 8: ...516912 R MANUFACTURING INC CINCINNATI OHIO...
Страница 11: ......
Страница 15: ...516913 R MANUFACTURING INC CINCINNATI OHIO...
Страница 16: ......
Страница 19: ......
Страница 20: ......
Страница 22: ......
Страница 24: ......
Страница 26: ......
Страница 32: ......
Страница 36: ...516914 R MANUFACTURING INC CINCINNATI OHIO...
Страница 38: ...416301 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 39: ...416302 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 40: ...416304 H200 7 15 98 INST INSTRUCTIONS VC 416 516 SUPERCEDES TITLE DATE SECTION MANUFACTURING INC...
Страница 42: ...516915 R MANUFACTURING INC CINCINNATI OHIO...