![Velleman APS230 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/velleman/aps230/aps230_manual_4036588056.webp)
56
A ps 2 3 0 A D VA N CE D Per s o n al S c o pe
TM
Trigger function
Note:
•
Changing the timebase or sensitivity
switches the autorange mode off.
•
The timebase or sensitivity cannot be
changed while in hold mode.
•
At higher timebase (0,1µs and faster) the
scope uses oversampling mode, only
repetitive signals are correctly displayed.
•
Use the minimum time base (50ns) as a
starting point when measuring a signal and
select a slower time base until the signal is
displayed properly. Otherwise the display
may not correctly reflect the signal under
measurement due to aliasing.
CHANGE THE TRIGGER CHANNEL
•
Press
the ‘TRIGGER’-key to set the cursor-
keys action into ‘trigger’ mode.
•
Use the
▲
or
▼
arrow buttons to select the
trigger channel.
Note:
The location of the trigger mode text and/or
the trigger position indicate(s) the channel
being used to trigger
(fig. 48 to 53).
Fig 48
Fig 49
Fig 50
Fig 51
Fig 52
Fig 53
CHANNEL 1
CHANNEL 2