VMBKP
20
Velbus
–
Legen Heirweg 33, BE-9890 Gavere, Belgium
–
tel. +32 9 384 36 11
–
e-mail: [email protected]
–
www.velbus.eu
PN-VMBKP-ed1-A4
REMARK:
While SUPER USER CODE # 7 is in operation to maintain the door unlocked, the functions that rely on the door sensor
(such as a magnetic contact)
5
and the User Codes for User Group 1 are all temporarily suspended until SUPER USER
CODE # 7 is entered again to release the door hold function.
The following are the temporarily suspended functions:
•
Door Auto-
relock (see “
on p.40)
•
Door Forced Open Warning (see “
Door forced open warning (location 80)
•
Door Propped-
up Warning (see “
Door propped-up warning (location 81)
•
Door Opening Alarm (see “
Egress mode, delay, warning beep and alarm (location 90)
•
All User Codes including the Super User Code for User Group 1
•
Duress Output activated by The Duress Code for User Group 1 (see “
Common user codes for User Groups 1 & 2 (locations 03 & 04)
The Common User Codes 1 and 2 are used for enhancing the security level of the User Group 1 and 2 channels
respectively. See Operation Mode 4 on p. 20
and “
Security level of the operation media
” on p.
13 for more information.
NOTE: a Common User Code alone can NOT operate the User Group channels directly.
Locations
Common user code
Validation
0 3
–
0 4
4 to 8 digits
#
1.
Locations
•
0 3 : location for the common user code for User Group 1
•
0 4 : location for the common user code for User Group 2
2.
Common user codes
•
The Common User Code can be 4 to 8 digits long.
•
When a new Common User Code is entered and validated, the old one is replaced.
3.
Validation
•
Press # key to confirm code entry.
Example
•
Set a Common User Code “1 3 5 7” for User Group 1:
0 3 1 3 5 7 #
•
To delete a Common User Code for User Group 1 from memory, key in the location number 0 3, followed by #: 0
3 #
User codes / cards for User Groups 1 & 2 (locations 10 & 20)
Locations
Mode
User ID
Card/User code
Validation
1 0 or 2 0
1
–
5
0 0 0
–
9 9 9
Card/user code entry
#
1.
Locations (User groups)
•
1 0 User Group 1: 1000 User codes / Cards for controlling User Group 1 channel
•
2 0 User Group 2: 100 User codes / Cards for controlling User Group 2 channel
2.
Mode (Operation Mode)-
see “
Security level of the operation media
” on page
13 for more information on the
security level of these modes
•
1
–
Cards Only
–
125Khz Proximity EM Card
5
cfr. “
Содержание VMBKP
Страница 1: ......