VMBKP
17
Velbus
–
Legen Heirweg 33, BE-9890 Gavere, Belgium
–
tel. +32 9 384 36 11
–
e-mail: [email protected]
–
www.velbus.eu
PN-VMBKP-ed1-A4
5.
Program a new Master Code to
replace the old one. See See “
18 for more
information.
NOTE: The keypad will set itself to normal operation mode 1 minute after power-up if the Egress Button is not pressed
and the DAP code is not keyed in. To set keypad back to power-up mode, repeat steps 1-4.
Refresh the system with the Refreshing Code --- 9 9 9 9
The keypad can be refreshed (cleaning all the programmed data and setting it back to default values, except the Master
Code).
Refreshing code
Validation
9 9 9 9
* *
NOTES:
a.
Make sure that refreshing the system is really required before entering the Refreshing Code.
b.
Refreshing may take a few minutes. The status LED (amber) keeps flashing during refreshing.
c.
The keypad is back to its default value after refreshing. Reprogramming of the desired values is necessary.
Default values after refreshing
LOCATION
PARAMETER
DEFAULT FUNCTIONS & VALUES
0 1
Master Code
Not refreshed (0 0 0 0 Factory
Set)
0 2
Super User Codes
Nil ----- User Program Required
0 3
Common User Code 1
Nil ----- User Program Required
0 4
Common User Code 2
Nil ----- User Program Required
1 0
User Codes & Cards for User
Group 1
Nil ----- User Program Required
2 0
User Codes & Cards for User
Group 2
Nil ----- User Program Required
4 0
Visitor Codes
Nil ----- User Program Required
4 1
Duress Code for User Group 1 Nil ----- User Program Required
4 2
Duress Code for User Group 2 Nil ----- User Program Required
5 1
Output Mode of User Group 1 Time = 5 Sec, Momentary
5 2
Output Mode of User Group 2 Time = 5 Sec, Momentary
5 5
System Real-Time Clock
Nil ----- User Program Required
5 6
Start & Stop Time
Nil ----- User Program Required
6 0
Personal Safety & Lock-out
Code = 1, Lock-out 60 seconds
after 10 False Codes/Cards
7 0
User Code Entry Mode
Code = 2, Manual Entry Mode