Enter a normal User Code to reset Duress (for example, 1369 is a user code for User Group 1 channel):
1 3 6 9
:
Duress Output resets (back to OFF state) but does not activate User Group Channel 1.
Report Duress in EM Card Operation
The Duress Codes are Prime User Codes in the system (cfr. “
). In the “EM Card + Secondary User
Code” or “EM Card + Common User Code” operation modes the
y can replace the Secondary User Code or the Common
User Code to operate the specific User Group channel
and
report a duress alarm event at the same time (see “
codes (for user groups 1 & 2) (locations 41 & 42)
26 for more information). Additional programming is not
required, this function exists automatically when a Duress Code exists.
Operation
Taking Duress Code 3 3 6 9 in User Group 1 as an example:
Read Card
3 3 6 9
#
(1)
(2)
(3)
1.
Read the EM card. A double beep confirms the reading and a 30 seconds delay is given for the entry of the Duress
Code, the amber LED keeps flashing
2.
Enter the Duress Code 3 3 6 9 for operating User Group 1 channel
3.
Confirm it with the # key. User Group 1 channel activates in a normal way and the Duress Output also activates to
report Duress Event to an alarm system if connected.
NOTE: A duress event can not be reported with an EM Card alone.
Output mode & Timing for User Group 1 & 2 channels (locations 51 & 52)
Location
Output mode & timing
Validation
5 1
–
5 2
0 or 1
–
9 9 9 9 9
#
(1)
(2)
(3)
1.
Location
•
5 1: Location for User Group 1
•
5 2: Location for User Group 2
2.
Output mode & timing
•
0: Start/Stop Mode (Toggle). The channel activates when a User Code is entered and/or a Card is read; the
channel deactivates when a User Code and/or Card is entered/read again.
•
1
–
9 9 9 9 9: Timer in seconds (default is 5 seconds). The User Group channel activates when a User Code is
entered and/or a Card is read and remains activated during the set time (1s
–
99,999s). The User Group channel
will deactivate automatically when the time expires.
3.
Validation
•
Press the # key once. A double beep confirms the entry.
Reset output timer with super user code
The Output Timer can be RESET manually at any time by entering the Super User Code before the time expires, followed
by # and the number of the User Group.
Example
SUPER USER CODE # 1: User Group 1 channel deactivates (and timer is reset)
SUPER USER CODE # 2: User Group 2 channel deactivates (and timer is reset)