Example 7
–
Report A Duress While Using a Card
The Duress Codes are Prime User Codes in the system (cfr. “
13). They can be used to replace the
Secondary User Code or the Common User Code to operate the specific User Group channel
and
report a duress alarm
event at the same time (see “
Duress codes (for user groups 1 & 2) (locations 41 & 42)
26 for more information).
Additional programming is not required, this function exists automatically when a Duress Code exists.
Operation (while the keypad is back in operation mode)
Read card
Duress Code #
(a)
(b)
(c)
(a)
Present the Card. A double beep confirms the reading and a 30 seconds delay is given for entry of the Duress
Code, the Amber LED keeps flashing
(b)
Enter the Duress Code for the specific User Group (the Code programmed in Location 41 or 42 for User Group 1 or
2 respectively)
(c)
Confirm it with the # key. The specific User Group channel activates in a normal way, but additionally the Duress
Output
6
also activates, e.g. to report a Duress Event to an alarm system.
NOTE: The Duress Event can not be reported if the operation mode is EM Card alone. In that case the Duress Code
needs to be entered directly instead of reading the EM card to report a Duress Event.
Visitor codes (for user group channel 1 only) (location 40)
The Visitor Codes are temporary user codes for User Group 1 channel. They can be programmed as “One Time Codes”
or “Codes with Time Limit”. One Time Visitor Codes will be cleared automatically after the first use. Visitor codes with
Time Iimit will be cleared when the allowed period expires when .
Location
Visitor ID
Valid period (in hours)
Visitor code
Validation
4 0
0 1
–
5 0
0 0 or 0 1
–
9 9
4-8 DIGITS
#
(1)
(2)
(3)
(4)
(5)
1.
Location
•
Key in location 4 0
2.
Visitor ID
•
0 1
–
0 1: 50 Visitor IDs for the 50 visitor codes. These are 2-digit numbers
•
0 9 9 9: Clear all the Visitor Codes in Location 40. See the programming example below for more information.
3.
Valid period
•
The codes in this box MUST be two digits. They represent the validity duration in hours.
•
0 0: One Time Code. A One Time Code has no time limit but it can only be used ONCE. It is cleared after use.
•
0 1
–
9 9: Time Limit in hour(s). The Visitor Code can be set with the valid time limit of 1 to 99 Hours with a two-
digit number of 01 to 99. The visitor code is cleared when the allowed period expires. The timer starts to run
when the programming is validated (# key).
4.
Visitor Codes
•
The Visitor Codes can be 4-
8 digits when Manual Mode code entry is active (see “
•
When Auto Mode code entry is active, the Visitor Codes MUST be the same digit length as the Master Code (see
•
The Visitor Codes can not reset the Duress
Output (see “
6