VMBKP
40
Velbus
–
Legen Heirweg 33, BE-9890 Gavere, Belgium
–
tel. +32 9 384 36 11
–
e-mail: [email protected]
–
www.velbus.eu
PN-VMBKP-ed1-A4
Application hints for the auxiliary terminals
Door sens
Use a Normally Closed door position sensor (usually a magnetic door switch) on the door to set up the following
functions:
Door Auto Relock
The system will immediately deactivate the User Group channel after the door closes again to prevent "tailgate" entries.
This function is automatically active and needs no additional configuration.
Door Forced-open Alarm
The keypad will emit warning beeps and close the ALM O/P
14
instantly if the door is forced open. Enable the function at
Location 80. For more information see “
Door forced open warning (location 80)
Door Propped-up Alarm
The keypad will emit warning beeps and close the ALM O/P
if the door is left open longer than the pre-set delay time.
Enable the function at Location 81. For more information see “
Door propped-up warning (location 81)
14
Cfr. “
Содержание VMBKP