SYSTEM CODE
FUNCTION
CODE ENTRY
RESULTS
0 0 0 0
MASTER CODE
Factory set Master Code (to set keypad in programming
mode).
THIS IS NOT A PERMANENT SYSTEM CODE, IT NO
LONGER EXISTS WHEN A NEW MASTER CODE IS
PROGRAMMED BY THE USER.
0 0 0 0 * *
OR
NEW MASTER CODE * *
System in Programming Mode
9 9 9 9
REFRESH CODE
Refresh the system and set all parameters back to
default values (except Master Code).
9 9 9 9 #
All programmed data are cleared &
all values are reset to default values
except the Master Code.
2 8 2 8
DAP CODE
Direct Access to Programming code. Valid only during
the power-up delay period.
2 8 2 8 #
System in Programming Mode
0 9 9 9
CLEAR USER CODES/CARDS FOR THE SELECTED
LOCATION
LOCATIONS:
10: User Group 1
20: User Group 2
40: Visitor Group
41: Duress Group 1
42: Duress Group 2
LOCATION 0 9 9 9 #
Whole group of users cleared for
the selected location
* *
EXIT PROGRAMMING CODE
* *
System back to normal operation
after programming