Chapter 7 Maintenance and Troubleshooting
JT550 Series Inverter Manua
l
- 72 -
Function
Codes
Parameter Name
Range of Settings
Default
Property
P0.03
Corresponding Setting of AI
Curve 4 Inflection Point 1
Input
-100.0%~+100.0%
30.0%
●
P0.04
AI Curve 4 Inflection
Point
2 Input
P0.02~P0.06
6.00V
●
P0.05
Corresponding Setting of
AI Curve 4 Inflection Point
2 Input
-100.0%~+100.0%
60.0%
●
P0.06
AI Curve 4 Maximum
Input
P0.04~+10.00V
10.00V
●
P0.07
Corresponding Setting of
AI curve 4 Maximum Input -100.0%~+100.0%
100.0%
●
P0.08
AI curve 5 Minimum Input -10.00V~P0.10
-10.00V
●
P0.09
Corresponding Setting of
AI Curve 5 Minimum Input -100.0%~+100.0%
-100.0%
●
P0.10
AI Curve 5 Inflection Point
1 Input
P0.08~P0.12
-3.00V
●
P0.11
Corresponding Setting of
AI Curve 5 Inflection Point
1 Input
-100.0%~+100.0%
-30.0%
●
P0.12
AI Curve 5 Inflection Point
2 Input
P0.10~P0.14
3.00V
●
P0.13
Corresponding
Setting of AI Curve 5
Inflection Point 2 input
-100.0%~+100.0%
30.0%
●
P0.14
AI Curve 5 Maximum
Input
P0.12~+10.00V
10.00V
●
P0.15
Corresponding Setting of
AI Curve 5 Maximum
Input
-100.0%~+100.0%
100.0%
●
P0.24
Jump Point of AI1 Input
Setting
-100.0%~100.0%
0.0%
●
P0.25
Jump Amplitude of AI1
Input Setting
0.0%~100.0%
0.5%
●
P0.26
Jump Point of AI2 Input
Setting
-100.0%~100.0%
0.0%
●
P0.27
Jump Amplitude of AI2
Input Setting
0.0%~100.0%
0.5%
●
P0.28
Jump Point of AI3 Input
Setting
-100.0%~100.0%
0.0%
●
P0.29
Jump Amplitude of AI3
Input Setting
0.0%~100.0%
0.5%
●
Group P1: AI/AO Correction Parameters
P1.00
AI1 Measured Voltage 1
0.500V~4.000V
Factory
Corrected
●
P1.01
AI1 Displayed Voltage 1
0.500V~4.000V
Factory
Corrected
●
P1.02
AI1 Measured Voltage 2
6.000V~9.999V
Factory
Corrected
●
P1.03
AI1 Displayed Voltage 2
6.000V~9.999V
Factory
Corrected
●