AC70 VC CONTROL FREQUENCY INVERTER MANUAL
APPENDIX
120
E-04
Frequency reference
given channel gain
0.01-5.00 1.00
〇
72 104H
E-05
Frequency reference
given channel
combination mode
0: Main channel is valid, auxiliary
channel is invalid.
1: Auxiliary channel valid,main
channel invalid
2: Both channel is valid if non zero
value, main channel priority
3: Main c K×auxiliary
channel
)
4: main channel -
(
K×auxiliary
channel
)
5: MAX [main channel ,
(K×auxiliary channel)]
6: MIN [main channel , (K×auxiliary
channel)]
7: Auxiliary c (K×main
channel)
8: Auxiliary channel - (K×main
channel)
9: MAX [(K×main channel),
auxiliary channel]
10: MIN [(K×main channel),
auxiliary channel]
0
〇
72 105H
E-06
Upper LED monitor
selection
0: Frequency Given
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Machine speed
6: PID given given
7: PID feedback value
0
●
72 106H
E-07
Lower LED monitor
selection
1
●
72
107H
E-08
REV/JOG key of keypad
function selection
0: Reverse
1: Jog
0
●
73
108H
E-09 Maximum
frequency 0.01-600.00Hz
50.00Hz
〇
73
109H
E-10
Upper limit frequency
lower limit frequency - maximum
frequency
50.00Hz
●
73
10AH
E-11
Lower limit frequency
0.00-Upper limit frequency
0.00Hz
●
73
10BH
E-12
Lower limit frequency
running mode
0: Stop
1: running with lower limit
frequency
1
●
73
10CH
E-13
Acceleration time 1
0.1-6500.0s
※
●
74 10DH
E-14
Deceleration time 1
0.1-6500.0s
※
●
74 10EH