à
C
heck if there is buildup on the vibrating element
,
and if
so
,
remove it
.
l
U
nfavourable installation location
à
M
ount the instrument at a location in the vessel where
no dead zones or mounds can form
.
à
C
heck if the vibrating element is covered by buildup on
the socket
.
l
W
rong characteristics selected
à
S
et the correct characteristics on the characteristics
reversal switch
(
over
fi
ll protection
,
dry run protection
).
W
iring should be carried out according to the quiescent
current principle
.
?
S
ignal lamp
fl
ashes yellow
l
F
ault in the electronics
à
E
xchange of the electronics module
?
S
ignal lamp
fl
ashes yellow
l
instrument defective
à
E
xchange instrument or return instrument for repair
7
.
3
E
xchange of the electronics module
I
n general
,
all oscillators of series
WE
60
can be interchanged
.
I
f you want to use an oscillator with a di
ff
erent signal output
,
you can download the corresponding operating instructions
manual from our homepage under
D
ownloads
.
W
ith
EE
x d instruments
,
the housing cover must only be
opened if there is no explosive atmosphere
.
P
roceed as follows
:
1
S
witch o
ff
power supply
2
U
nscrew the housing cover
3
L
ift the opening levers of the terminals with a screwdriver
4
P
ull the connection cables out of the terminals
5
L
oosen the two screws with a screw driver
(
T
orx size
T
10
or slot
4
)
26
VEGAWAVE
63
- -
NAMUR
M
aintenance and fault recti
fi
cation
32259
-
EN
-
070117
Содержание VEGAWAVE 63
Страница 1: ...Operating Instructions VEGAWAVE 63 NAMUR ...
Страница 36: ...ø 34 mm 1 11 32 178 mm 7 1 64 Fig 21 Temperature adapter Supplement 36 VEGAWAVE 63 NAMUR 32259 EN 070117 ...
Страница 38: ...Supplement 38 VEGAWAVE 63 NAMUR 32259 EN 070117 ...
Страница 39: ...Supplement VEGAWAVE 63 NAMUR 39 32259 EN 070117 ...