22
8 Supplement
VEGAPULS 6X • Two-wire 4 … 20 mA/HART
66376-EN-220111
8 Supplement
8.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Electromechanical data - version IP66/IP67 and IP66/IP68 (0.2 bar)
Options of the cable entry
Ʋ Cable entry
M20 x 1.5; ½ NPT
Ʋ Cable gland
M20 x 1.5; ½ NPT (cable ø see below table)
Ʋ Blind plug
M20 x 1.5; ½ NPT
Ʋ Closing cap
½ NPT
Material ca-
ble gland
Material seal
insert
Cable diameter
4.5 … 8.5 mm
5 … 9 mm
6 … 12 mm
7 … 12 mm
10 … 14 mm
PA
NBR
-
●
●
-
●
Brass, nickel-
plated
NBR
●
●
●
-
-
Stainless
steel
NBR
-
●
●
-
●
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Power supply PLICSMOBILE
Operating voltage
7)
9.6 … 32 V DC
Power consumption
8)
Ʋ Power saving mode (9 V/12 V)
0.18 mW/0.3 mW
Ʋ Power saving mode (24 V/32 V)
1.8 mW/3.7 mW
Ʋ Permanent operation
1.1 W
Ʋ Peak power (measured value trans-
mission)
11 W
Power requirement
9)
Ʋ Measurement cycle incl. transmission 15 mWh
Sensor power supply
Ʋ Off-load voltage
31 V (24 V with Ex version)
7)
When the instrument is powered by an external voltage supply, make sure the voltage supply unit has a suf-
ficient current carrying capacity. With a voltage supply < 9.6 V, current peaks of up to 2 A must be expected.
8)
The listed power specifications include the voltage supply of a HART sensor with 20 mA.
9)
The listed energy requirement includes the voltage supply of a HART sensor (VEGAPULS 61 with 4 mA
(multidrop mode) and 12 V operating voltage.