TLS-450 Setup and Operation Screens Manual 

 

138 

 

Ethernet Comm Devices – General (page 3) 

Subnet Mask  

NOTE: Changing the Subnet Mask will require a reboot of the console. 

 
Format - The format of this field will use the IPv4 dot-decimal notation, e.g. 192.0.2.235 
 
Allowable selections: Numeric XXX.XXX.XXX.XXX (0 to 255 each field). Default: 255.255.255.0 

Gateway IP 

Format - The format of this field will use the IPv4 dot-decimal notation, e.g. 192.0.2.235 
 
Allowable selections: Numeric XXX.XXX.XXX.XXX (0 to 255 each field). Default: 0.0.0.0 

Primary DNS Server 

Format - The format of this field will use the IPv4 dot-decimal notation, e.g. 192.0.2.235 
 
Allowable selections: Numeric XXX.XXX.XXX.XXX (0 to 255 each field) 
Default: 0.0.0.0 

Secondary DNS Server 

Format - The format of this field will use the IPv4 dot-decimal notation, e.g. 192.0.2.235 
 
Allowable selections: Numeric XXX.XXX.XXX.XXX (0 to 255 each field). Default: 0.0.0.0 

Serial Command Port 

In a multi-Ethernet Comm Device configuration, any changes this Field for one Ethernet Comm 
Device will not affect the same Field of the other Ethernet Comm Devices. 
 
Allowable selections: Numeric 1 to 65535. Default: 10001  
 
NOTE: For an Ethernet Comm Device, if you set up two or more of the Serial Command, SSH, HTTP 
or HTTPS Ports with the same number, communications may be compromised.  No warning 
messages will be provided. 
 

Ethernet Comm Devices – General (page 4) 

SSH Port 

In a multi-Ethernet Comm Device configuration, a change to this Field for one Ethernet Comm Device 
will be reflected in the same Field of the other Ethernet Comm Devices (will be made the same). 
 
Allowable selections: Numeric 1 to 65535. Default: 22 
 
NOTE: For an Ethernet Comm Device, if you set up two or more of the Serial Command, SSH, HTTP 
or HTTPS Ports with the same number, communications may be compromised.  No warning 
messages will be provided. 

 

Содержание TLS-450

Страница 1: ...Manual No 577013 940 Revision F Screens Manual TLS 450 Setup and Operation...

Страница 2: ...and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax signed...

Страница 3: ...To Do About It 17 Changing Printer Paper 20 SETUP SCREENS 21 Main Setup 21 Date and Time Setup 22 Date Time Setup Daylight Savings 22 Date Time Setup Date Time Set 24 Display Setup Language and Units...

Страница 4: ...98 Pumps and Lines 101 PLLD Setup Overview 101 Pumps and Lines Setup Pumps 102 Pumps and Lines Setup Lines 104 Pumps and Lines Setup All Lines 106 Line Lockout Schedule Daily 106 Line Lockout Schedule...

Страница 5: ...screen 155 Add Edit Contact Entry Modem 156 Control Buttons lower right of screen 157 Add Edit Contact Entry Fax 158 Control Buttons lower right of screen 159 Add Edit Contact Entry TCP IP 160 Control...

Страница 6: ...story 197 Report Column Descriptions 197 Control Button on right of screen 198 Inventory Reports Shift Inventory 199 Report Column Descriptions 199 Environmental Reports 201 Environmental Reports Comb...

Страница 7: ...y Compliance 238 Tank Test Diagnostics CSLD Monthly 239 Report Column Descriptions 239 CSLD Monthly Report Refresh Rate 240 Control Buttons on right of screen 240 Regulatory Compliance 240 Tank Test D...

Страница 8: ...Control Buttons Right side of screen 272 Reconciliation 273 Reconciliation Diagnostics Status 273 Report Column Description 273 Control Buttons on right side of screen 274 Reconciliation Diagnostics...

Страница 9: ...creen 300 Sensor Diagnostics 3 Wire CL 301 Report Column Descriptions 301 Sensor Diagnostics 3 Wire CL Sensor Refresh Rate 302 Control Button right of screen 302 Mag Sensor 303 Mag Sensor Diagnostics...

Страница 10: ...8 Module Diagnostics Device Directory 330 Report Column Descriptions 330 Module Diagnostics Device Assignments 331 Report Column Descriptions 331 Module Diagnostics Comm 333 Report Column Descriptions...

Страница 11: ...tion Screens Manual xi Table of Device Identifiers 361 Table of Module Device Identifiers 362 Table of Standard Abbreviations 362 Table of Unit Abbreviations 363 Table of Unit Conversions 364 Table of...

Страница 12: ...ne preparation and line leak detector installation ATG Technician Level 2 3 or 4 Certification Contractors holding valid ATG Technician Certifications are approved to perform installation checkout sta...

Страница 13: ...anuals thoroughly If you do not understand a procedure ask someone who does Safety Warnings This system operates near highly combustible fuel storage tanks Leaking tanks can create serious environment...

Страница 14: ...is time to change the roll Item 2 System Visual Status LEDs The check symbol is beneath a green LED When the green LED is lit there are no alarms active normal The exclamation symbol is beneath a yell...

Страница 15: ...per second 2 Alarm Report button When an alarm occurs this button will flash and the console beeper will activate Touch this button once to display the Active Alarms Report screen Once the Active Alar...

Страница 16: ...etup button displays the main System Setup Screen 10 Diagnostic button Touching the Diagnostic button displays the main Diagnostic Screen 11 Shift Close button Touching the Shift Close button displays...

Страница 17: ...o help identify the current screen in the Data View area Information related to the name of the screen selected tab screen name and specific device or object being displayed will be present The right...

Страница 18: ...a area displays the information associated with any selected setup report or diagnostic screen Tabs at the top of the data area All Tanks All Sensors User Defined 1 etc in the diagram below if present...

Страница 19: ...ts you can scroll through it and select any topic for display Item 2 Edit Help button If this feature is enabled you can touch this button to view add your own text to the default text for any selecte...

Страница 20: ...lues in a Field When you make an entry or change to a field on a screen an asterisk is displayed on the currently viewed tab and beside the edited field see star highlights in example below Touch the...

Страница 21: ...field value being entered Field Edit Region This is the view area to show the value as it is being entered entries are left justified Character Entry Region This region has Buttons that enter charact...

Страница 22: ...of the field value being entered Field Edit Region This is the view area to show the value as it is being entered entries are right justified Character Entry Region This region has Buttons that enter...

Страница 23: ...for the currently selected language This dialog is used to enter alpha numeric fields and special alpha numeric fields like phone numbers IP addresses etc Field Name Region This is the title area that...

Страница 24: ...ch this button to apply the selection o Cancel touch this button to discard any selections that have been made o touch this button to move the cursor to the left o touch this button to move the cursor...

Страница 25: ...er Mode is Complete 2 Setup the TLS 450 Console A site that has a brand new TLS 450 with Wireless 2 devices 1 Power up all wireless devices 2 Power up the TLS RF Console and wait about 5 minutes befor...

Страница 26: ...nks Setup in order of the Tab Screens left to right 7 Pumps and line Setup in order of the Tab Screens left to right 8 Automatic Events Setup do after above setups make sure communications is setup fi...

Страница 27: ...he alarm s The warning and alarm label s will continue to display scroll in the System Status box until you correct the cause of the problem If your system has a printer and it has been programmed to...

Страница 28: ...e alarms Acknowledging alarms does not clear them that requires fixing the cause of the alarm How Do I Learn More About an Alarm and What To Do About It You can access all alarm reports Active History...

Страница 29: ...rm Help screen in which its cause and a suggested corrective action are shown see Delivery Needed alarm example below You can touch the More About Active Alarms link at the bottom of the Alarm Help sc...

Страница 30: ...s and hazards involved refer all service to a qualified Veeder Root Service Representative Attempting to service tank monitors and equipment without proper training can cause damage to property enviro...

Страница 31: ...er from the printer by clasping both sides of the paper where it goes under the small paper feed roller and gently pulling out and down 4 Remove and discard the old roll of paper 5 Unfasten the end of...

Страница 32: ...on navigators to all device setups in the console If a button is dimmed it is a disabled feature that is unavailable Available system setups are discussed below NOTE the term tab screen as used herein...

Страница 33: ...the first Sunday in November In the U S each time zone switches at a different time In the European Union Summer Time begins and ends at 1 00 a m Universal Time Greenwich Mean Time It begins the last...

Страница 34: ...rmat Minutes Allowable Selections 0 to 59 AM PM if 12 Hr Format Allowable Selections AM PM End Date Allowable Selections See below Default NOV FIRST WEEK SUN Select Month Allowable Selections January...

Страница 35: ...the current Date and Time for the console Set Current Date Enter the current date Allowable selections Month 1 12 Day 1 31 Year 1970 2038 Default Today s date Set Current Time Enter the current time A...

Страница 36: ...its The Display Setup Language and Units screen lets you select the language and units to be used in all screens and print outs System Language Allowable selections English Chinese French or Spanish D...

Страница 37: ...ormat screen lets you select the date format to be used in all screens and print outs Date Format Allowable selections YYYY_MM_DD DD_MM_YYYY MM_DD_YYYY MON_DD_YYYY Default MM_DD_YYYY Date Separator Al...

Страница 38: ...p Number Format The Display Setup Number Format screen lets you select the numerical separators to be used in all screens and print outs Decimal Separator Allowable selections or Default Thousands Sep...

Страница 39: ...t to each of these tab fields is an advanced setup button This button will launch a screen with additional choices related to the tab that has been enabled All Tanks Tab Selecting Enable in the All Ta...

Страница 40: ...Tab Advanced Setup screen In this screen you can create your own tab label as well as populate the display with your choice of tanks and sensors Allowable selections Enabled Disabled Default Enabled U...

Страница 41: ...status graphic displayed on the home screen System Status All Tanks and on any System Status User Defined status screens if assigned To assist you in deciding about your choices the changes to the ta...

Страница 42: ...Allowable selections Disabled Bottom Text On Tank Default Bottom Text Alarm Condition Icon Allowable selections Enabled Disabled Default Enabled Delivery Indicator Allowable selections Enabled Disabl...

Страница 43: ...status graphic Fuel Fill Selection This selection lets you configure the fuel patterns to display as fuel levels in a selected tank Touch any tank button on the bottom of the screen then select the d...

Страница 44: ...l comprise the content of that sensor s status graphic displayed on the home screen System Status All Sensors and on any of the System Status User Defined screens if assigned To assist you in deciding...

Страница 45: ...wable selections Enabled Disabled Default Disabled Category Allowable selections Enabled Disabled Default Disabled Type B 3 wire CL Sensors Sensor Label Allowable selections Enabled Disabled Default D...

Страница 46: ...ns Enabled Disabled Default Disabled Ground Water Sensors Sensor Label Allowable selections Enabled Disabled Default Disabled Alarm Condition Icon Allowable selections Enabled Disabled Default Disable...

Страница 47: ...nual 36 Line Pressure Sensors Sensor Label Allowable selections Enabled Disabled Default Disabled Alarm Condition Icon Allowable selections Enabled Disabled Default Disabled Pressure Allowable selecti...

Страница 48: ...the lower right of the screen A page is considered configured if it contains at least one valid device entry Initially the setup area will show one page where none of the device positions are assigned...

Страница 49: ...nfo set Use the header to identify site location phone number etc Header 1 Allowable selections Alphanumeric Text Field Length 20 Characters Default Empty Header 2 Allowable selections Alphanumeric Te...

Страница 50: ...sent at the top of faxes transmitted by the console Allowable selections Alphanumeric Text Field Length 30 Characters Default Empty Fax Sender Number Enter the phone number the console will dial from...

Страница 51: ...creens and print out end user reports While you remain logged in a log out button will be visible in the lower right side of the System Status screen Once you are logged in timeout rules will apply as...

Страница 52: ...you will be logged out and the console will return to the System Status window in log out mode No warning will be given before the session timeout If the timeout occurs before you have saved changes o...

Страница 53: ...at the bottom of the screen Configured Note 1 Do not enable probe until its address is assigned 2 Once enabled do not disable probe if it is assigned to a tank You must first unassign the probe from t...

Страница 54: ...elow are enabled for edit 2 Only circuit codes D004 D005 and D006 are allowed to set the float type to 4 in phase separation Fuel Offset Custom Float Type Allowable selections 8 in to 8 in 203 2 to 20...

Страница 55: ...867 D023 GLB10 0 060 3 000 D024 GLB11 0 060 3 000 3 4 CUSTOM FLOAT DEFAULTS Circuit Code Name Type 4 Floats 3 Floats Water Offset Fuel Offset Invalid Fuel Water Min Water Offset Fuel Offset Invalid F...

Страница 56: ...wable selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of available external inputs Not Assigned Default Not Assigned Label Allowable selections Up...

Страница 57: ...ting this relay type when one IQ controlled pump of a manifolded set is turned On for line leak testing the relay will activate blocking communication with the second IQ controlled pump giving the con...

Страница 58: ...bel Allowable selections Up to 20 alphanumeric characters Default Blank Type Enter the type of input Standard Generator Pump Sense or Standard ACK that is connected to the selected input location STAN...

Страница 59: ...ons Standard Generator Pump Sense Standard ACK Default Standard Orientation You must identify the input switch orientation as either normally open or normally closed so the console properly recognizes...

Страница 60: ...ach of your site s liquid sensor setups by touching the desired button at the bottom of the screen Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selections Choose...

Страница 61: ...rmally Closed Dual Point Hydrostatic Dual Float Discriminating Dual Float High Vapor Interceptor Sensor DW Sump 2 1 Sensor Default Tri State Single Float Category Select the sensor s category location...

Страница 62: ...ton at the bottom of the screen Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of available Type A sensors Not Assigned Defau...

Страница 63: ...eration Screens Manual 52 Category Select the sensor s category location from the drop down list Allowable selections Other Sensors Annular Space Dispenser Pan Monitor Well STP Sump Containment Sump D...

Страница 64: ...sor setups by touching the desired button at the bottom of the screen Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of avail...

Страница 65: ...lowable selections Ultra Z 1 4Site Pan Sump Standard Ultra Z 1 HV 4Site Pan Sump High Vapor Default Ultra Z 1 Category Select the sensor s category location from the drop down list Allowable selection...

Страница 66: ...dress has been assigned If your console has the internal printer touch the Print button to printout the Mag Sensor Setup On the printout look at the factory preset Alarm Delay and Alarm Threshold sett...

Страница 67: ...ag Sensor s serial number Alarm Delay This display appears if the alarm delay has been factory set to programmable This is the time in hours following the triggering of uncleared warnings before they...

Страница 68: ...e selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of available Groundwater sensors Default Not Assigned Label Allowable selections Up to 20 alphanu...

Страница 69: ...setups by touching the desired button at the bottom of the screen Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of available...

Страница 70: ...em contains electrical voltages that can be lethal Electrical shock resulting in serious injury or death could result if incorrect service procedures are used When you perform the following procedure...

Страница 71: ...re sensors that have been connected to the console Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selections Choose from drop down list of available Line Pressure...

Страница 72: ...u access each of your site s LVDIM or MDIM setups by touching the desired button at the bottom of the screen Configured Allowable selections Enabled Disabled Default Disabled Address Allowable selecti...

Страница 73: ...onversion Allowable selections 1 2 2 5 10 25 100 250 500 1000 or Custom Default 1 2 Custom This field is only available if Custom is selected for Pulse Conversion above Enter a custom pulse conversion...

Страница 74: ...must be true 1 A probe must be assigned to the tank 2 The probe must have a valid address 3 The tank must have a viable chart as follows All charts must include diameter and full volume A 4 point cha...

Страница 75: ...ank is one to one i e Probe 1 assigned to Tank 1 Probe 2 assigned to Tank 2 etc Allowable entry Select this probe s identifier from the drop down list Default Not Assigned Probe Offset This offset is...

Страница 76: ...085 Hydraulic Oil 0 00047 0 00085 Jet Fuel 0 00047 0 00085 Kerosene fuel oil 1 Paraffin 0 00050 0 00090 Liquefied Petroleum Gas LPG Propane 0 00160 0 00288 Liquefied Petroleum Gas LPG Butane 0 00109 0...

Страница 77: ...4 to 144 in 3657 60 to 3657 60 mm Default 0 Delivery Delay Enter the number of minutes to wait after the Console determines that a Delivery is complete This delay period can prevent false Alarms and W...

Страница 78: ...t points These values apply to the currently selected Tank Maximum Volume Label Volume Maximum or Label Volume alarm warns when the level of fluid in the tank exceeds the volume you enter here Set thi...

Страница 79: ...activate an Overfill Alarm and triggers a printout showing the Tank number date time and product Set this percentage no greater than 90 of the Tank s capacity In international installations set this...

Страница 80: ...ore detail below LOW FILTER When the Water Alarm Filter is set to Low Deliveries will not inhibit the posting of Water Alarms With the Low setting the Console detects that a Delivery is occurring when...

Страница 81: ...er level is six inches or above the High Water Alarm value for three minutes then the Console posts a High Water Alarm and High Water Warning even when a Delivery is in progress HIGH FILTER The Water...

Страница 82: ...r greater Consider both the leak rate you wish to identify and the length of the test when determining a value for Leak Alarm Limit A value of 8 gallons 32 liters will warn of A 1 gph 4 lph leak in 8...

Страница 83: ...s this test and provides the settings by which the test will be conducted However enabling a test is not the same as starting the test which may be started at a later point Tank Test Method SLD Static...

Страница 84: ...0 38 lph Default 0 2 gph 0 76 lph Periodic Test Type Two periodic SLD test types are available 1 Standard performs a 2 hour periodic leak test 2 Quick performs a 0 2 gph 0 76 lph test in one hour This...

Страница 85: ...choice is Annually by Day of Week Monthly by Day of Week Day of Month 1 31 1 If Period choice is Annually by Day of Month Monthly by Day of Month Time of Day Time in Hours and Minutes 12 Hr sensitive...

Страница 86: ...gph test rate 2 It is less than 8 hours from a delivery if Standard test or 5 hours from delivery for Quick test 3 The product temperature is less than 0 F 17 6 C or more than 100 F 37 4 C 4 The fuel...

Страница 87: ...m appears in this field a special value has been entered remotely Do not change the selection from Custom Allowable selections 95 99 or Custom Default 95 Climate Factor If Climate Factor is set to Mod...

Страница 88: ...ion which interferes with normal CSLD leak detection monitoring by causing false leak alarms Note This selection field will be enabled only if Climate Factor is set to Extreme Allowable selections Ena...

Страница 89: ...the User Ullage volume as well as enable the User Ullage field When this field is disabled User Ullage will not be displayed by the GUI Allowable Selection Enabled Disabled Default Disabled User Ullag...

Страница 90: ...enter a Reid Vapor Pressure RVP value for at least 1 month of the year The RVP monthly values for your geographical area can be obtained from your local Petroleum Distributor Allowable range of valid...

Страница 91: ...efore Annual Warning Allowable Selection 0 365 Default 355 days Days Before Annual Alarm Allowable Selection 0 365 Default 365 days TC Density Allowable Selection Enabled Disabled Default Disabled Den...

Страница 92: ...conciliation reports Report Column Descriptions Product This column contains the product number Product Label This column contains the assigned label for the product number The default is Not Assigned...

Страница 93: ...max Default Not Assigned or Current product label Touch the button to accept edited values or button to abort the change and close the Edit Product Label dialog box Set Tanks Product Touch this butto...

Страница 94: ...d tanks into product summarized Reconciliation reports Report Column Descriptions Tank s This column contains the Tank number Product This column contains the product assigned to the tank The default...

Страница 95: ...ed it will appear in this field e g F1 Regular Unleaded If the selected tank has no product assigned Not Assigned will appear in this field Touch the down arrow to the right of this field to edit or a...

Страница 96: ...50 Setup and Operation Screens Manual 85 Tank Setup View All Products Touch the View All Products button to display the Tank Setup View All Products screen This screen displays all Product Tank assign...

Страница 97: ...the tank This selection is used for horizontally installed flat ended cylindrical tanks and should be selected when AccuChart II is available for this type tank 4 Points This method requires 4 volume...

Страница 98: ...0 to 999 999 litres Diameter 0 to 390 0 inches 0 to 9906 00 mm Enter volumes at read only heights Height values for the points within the chart are automatically displayed and are read only These hei...

Страница 99: ...urce and volume entries are user programmable for new charts and read only for charts being updated or viewed Viewing a Manually Calibrated Tank Chart Open the Tank Setup Manual Calibration screen for...

Страница 100: ...anifolded tanks you can select one of the following source options User Entered or Metered Drop For siphon manifolded tanks you can only select the following option User Entered USER ENTERED METHOD Th...

Страница 101: ...or select Volume Change if the meter displays actual volume for each dispense 4 The Max Step field is read only and the volume displayed cannot be exceeded from one point to another 5 Touch OK check...

Страница 102: ...t your entries and close the dialog 6 Touch the Add Point button on the right of the screen to open the Add Edit Tank Chart Point dialog box For Point 1 enter the tank s full capacity in the Volume fi...

Страница 103: ...Check OK key to make this chart active for the selected tank The Warning Update Schedule is active and may override your choice of active chart message indicates that the Update Schedule selection ma...

Страница 104: ...cribed below Function Allowable Selections Create New Chart Update Non Active Chart or View Chart Default Create New Chart Chart Name Enter a name for the chart you want to created or for the tank cha...

Страница 105: ...rt This is the name you entered for the chart Possible format 20 alphanumeric characters Date Time This column shows the date the chart was created Message format MM DD YYYY HH MM Type The column disp...

Страница 106: ...e until you have selected touched one of the charts in the report Apply Touch this button to make the selected chart the active chart for this tank Delete Touch this button to delete the selected char...

Страница 107: ...is composed of a list of tanks that are siphon manifolded together See Figure 1 below The maximum number of Siphon Sets that can be configured is the maximum number of tanks divided by 2 rounded down...

Страница 108: ...nk if no tanks are present for the siphon There will be only one parameter entry field labeled Siphon Set present initially when a new siphon is selected When a new siphon set is created or an existin...

Страница 109: ...applied Periodic You can pick up to 4 target dates on which the best chart created by AccuChart II will be made active This will only occur if there is a chart available on that date The target date...

Страница 110: ...iod for the premium tank If at one day prior to the end of your Calibration Period selection AccuChart II has insufficient data to create a tank chart it posts a warning if the AccuChart II Warning fi...

Страница 111: ...1 through 4 fields will be grouped at the bottom of the set This may cause the entered values to move around 3 If the calibration is in progress and the console clock is set back before the start of...

Страница 112: ...desired tank from Tank drop down d Select desired relay from Pump Control drop down e Select desired external input from Pump Sense drop down f Set Configured to Enabled 5 Configure Lines in Pumps and...

Страница 113: ...led features Allowable selections Enabled Disabled Default Disabled Pump Label Enter a unique label or name for the selected pump Allowable selections Up to 20 alphanumeric characters must be unique f...

Страница 114: ...are usually unique for each pump A warning dialog will display if the pump control selected is already assigned to another pump this alert is not an alarm or error since some sites use a single pump...

Страница 115: ...that can be configured is equal to the Maximum Number of Tanks your console was programmed to monitor when purchased A line is considered manifolded if it contains more than one pump Pumps are added t...

Страница 116: ...greatest inventory volume Sequential If there is more than one tank with a pump on the line tanks are pumped low one at a time until volume drops below pump threshold percentage At that point pumping...

Страница 117: ...ing hours when the site is unattended The Line Lockout Schedule provides a flexible means of locking out line leak tests in accordance with business hours The Lockout schedule identifies the hours not...

Страница 118: ...mmed to lock out the test from Friday night to Monday morning if the site is closed for the weekend If lockout schedules are programmed incorrectly the line leak tests may not run Make sure you have p...

Страница 119: ...dge Default Pass line test Periodic Test Needed Warning Periodic Test Needed Warning when enabled informs you that a line will soon be out of compliance because a Periodic test has not completed withi...

Страница 120: ...ious TLS consoles this was referred to as Precision Test Duration Allowable selections 12 to 744 hours Default selection 12 hours Note when CSLD is enabled for the tank assigned to the line a minimum...

Страница 121: ...the Leak Monitoring is enabled in Lines Setup will be shown on the lines buttons at the bottom of the screen Automatic dialing or sending of PLLD alarms is setup in Automatic Events setup Shutdown fo...

Страница 122: ...m N A OPW PISCES CP20 30 500ft 10 152m N A OPW PISCES SP20 20 1100ft 6 335m N A USER DEFINED 20 1100ft 6 335m 20 1100ft 6 335m PETROTECHNIK UPP EXTRA 63MM 20 1100ft 6 335m N A Line Length This field e...

Страница 123: ...ine length is non zero and Line Diameter is still default 2nd Line Bulk Modulus Allowable selections 1000 to 200 000 psi 6892 to 1 378 359kPa Default is 0 and user can set this field back to default I...

Страница 124: ...s then observed Following the test blockout period the test sequence repeats after the next dispense This selection also enables manual 0 1 gph 0 38lph testing Note The Repetitive option is not availa...

Страница 125: ...e option of entering custom alarm labels that will accompany the system s alarm labels in printouts and in the system status display Custom Alarms Lets you create custom alarm labels or important info...

Страница 126: ...s i e LCD flag LED flag and Beeper flag Report Column Descriptions Device Type Lists the device type Device Number Lists the device number The Device Number displays ALL if the alarm label is set for...

Страница 127: ...if any LCD Indication Lists if a LCD flag is enabled disabled following an alarm by this device LED Indication Lists if the front panel LED flag is enabled disabled following an alarm by this device...

Страница 128: ...rm labels within that alarm category To enter a custom alarm label select an alarm category and then select the alarm you want to re label This opens the Customization of Alarms dialog box with the fo...

Страница 129: ...m Label Enter your custom alarm label that will be displayed along with the standard alarm label when this alarm occurs Allowable selection 1 to 20 alphanumeric characters Default selection Blank Cont...

Страница 130: ...ic s displays when the online help topic s is selected Allowable selections Enabled Disabled Default selection Disabled Custom Help Edit This field lets you enable the online help Create Edit feature...

Страница 131: ...ct the desired alarm category using the drop down box Alarm Type Select the desired alarm type for the selected category using the drop down box Control Buttons on right of screen Create Edit Touch th...

Страница 132: ...he shift for ALL tanks but the tank s must be idle before a shift can close Once a Timed shift has been closed no other shift can be closed until the shift duration ends 2 When shift close is set to M...

Страница 133: ...rent or historical reports Allowable selections Timed Manual Default Timed Shift Close Timeout Select a Shift Close Timeout period Manual Shift Close Method only Allowable selections 3 to 60 minutes D...

Страница 134: ...up start times for each of the previously selected number of timed shifts up to eight Shift 1 up to Shift 8 Touch the down arrow to the right of each shift to select a desired start time Repeat for ea...

Страница 135: ...Disabled 5 min 10 min 15 min 20 min 30 min 1 hr 2 hrs 3 hrs 4 hrs 6 hrs 8 hrs 12 hrs or 24 hrs Default Disabled Storage Length This is a read only field which displays the maximum number of records L...

Страница 136: ...ucks Enabling this feature generates reports showing delivery variances between ticketed volume and gauged volume and book variance Allowable selections Enabled or Disabled Default Disabled TC Tickete...

Страница 137: ...ault is 1 00 of total meter sales throughput plus 130 gallons 492 litres offset In the U S the EPA has set this default as a criteria not to be exceeded The Product Threshold Alarm is triggered when t...

Страница 138: ...perature Compensation This field allows you to choose whether or not to calculate Business Inventory Reconciliation BIR volumes using the Programmable Temperature Compensation TC value Select STANDARD...

Страница 139: ...In the case of multiple references the largest threshold value is used to determine the result The threshold references are Percentage of throughput vol offset Percentage of tank capacity vol offset...

Страница 140: ...he system default is 1 00 of total meter sales throughput plus 130 gallons 492 litres offset In the U S the EPA has set this default as criteria not to be exceeded Alarm Threshold must be between 0 00...

Страница 141: ...eded Alarm Threshold must be between 0 00 and 9 99 percent Allowable selections 0 00 to 9 99 Default 1 00 Vol Offset Enter the offset amount to be added to the of Deliveries value that will trigger th...

Страница 142: ...ill be read only and inaccessible to for changes Other fields will be editable and the configuration can be changed Each type of Comm Device will have a set of Tabs to organize its own specific setup...

Страница 143: ...C RS 232 C RS 485 C RS 232 C RS 485 SiteFax Modem Serial NC C NC C CDIM DIM C NC C NC Comm Device Comm Type Slot 3 Slot 4 Slot 5 Port 1 Port 2 Port 1 Port 2 Port 1 Port 2 RS 232 Single Port also EDIM...

Страница 144: ...thin this topic Touch the applicable link below to jump to the desired setup RS 232 RS 485 Internal Modem Satellite Hughes H JBox and Satellite S Sat Comm Devices Ethernet Devices EDIM Devices CDIM De...

Страница 145: ...of Comm Devices and to set up their communication properties Configured Allowable selections Enabled Disabled Default Disabled Slot Allowable selections List None Default None Port Some Comm Devices...

Страница 146: ...ble selections List None Default None Label Enter a unique label for the Comm Device Allowable selections Up to 20 alphanumeric characters Default Comm Device Identifier and number Baud Rate RS 232 RS...

Страница 147: ...system the system will no longer have a Default Gateway and gateway dependent communication will be compromised To regain gateway dependent communication another Ethernet Comm Device will need to be e...

Страница 148: ...t Comm Devices will remain Static and cannot be changed to Dynamic from their own screens To set another Ethernet Comm Device to Dynamic the user will have to set the Ethernet Comm Device currently de...

Страница 149: ...235 Allowable selections Numeric XXX XXX XXX XXX 0 to 255 each field Default 0 0 0 0 Serial Command Port In a multi Ethernet Comm Device configuration any changes this Field for one Ethernet Comm Dev...

Страница 150: ...ommand SSH HTTP or HTTPS Ports with the same number communications may be compromised No warning messages will be provided HTTPS port In a multi Ethernet Comm Device configuration a change to this Fie...

Страница 151: ...one Dial Tone Interval Select a no dial tone alarm wait interval Allowable selections 0001 to 9999 hours Default 32 Answer On Enter number of rings Allowable selections 0 to 9 Default 1 Dial In Config...

Страница 152: ...lt Disabled Slot Read only when slot is detected otherwise enter the configurable slot number EDIMs 1 2 3 or 4 Allowable selections List None Default None Port Some DIM Devices can have more than one...

Страница 153: ...e Identifier and number EDIM Comm Devices General page 2 DIM Protocol Touch the down arrow to the right of this field and enter the applicable DIM Protocol for your DIM card Allowable selections See T...

Страница 154: ...Odd 7 1 1 2 NOTES 1 DIMs implemented for V402 2 Metric is the default setting for unit conversion Requires G in parameter string for gallon units EDIM References EDIM Parameter String Chart Baud Parit...

Страница 155: ...omm Setup DIM This screen allows you to enter EDIM reporting parameters Units Reported Allowable selections U S Metric or Imperial Default U S Suppress Communication Alarm This selection is for V R Pr...

Страница 156: ...ed Slot Read only when slot is detected otherwise enter the configurable slot number CDIMs 1 2 or 4 preferred Allowable selections List None Default None Port Some DIM Devices can have more than one p...

Страница 157: ...ill be available Setting the Device to None will also set all the common fields and button icons along the bottom of screen to their default values thereby marking the entry as removed from the config...

Страница 158: ...ble selections Gilbarco CL Wayne CL or Unknown Default Unknown CDIM Quick Reference Chart DIM P N Software Rev Protocol Baud Rate Default Parity Default Data Bits Default Stop Bits Default Notes Pass...

Страница 159: ...the desired setup RS 232 RS 485 Internal Modem Satellite Hughes H JBox Satellite S Sat and Ethernet Comm Devices Advanced Tab Setups EDIM Advanced Tab Setups CDIM Advanced Tab Setups RS 232 RS 485 Int...

Страница 160: ...numeric characters ASCII value 0 to 255 Default Blank ETX Characters Computer Accepts non printable characters through the GUI Enter hex value as string with an opening and closing bracket Convert te...

Страница 161: ...x06 0x15 Allowable selections 1 or 2 alpha numeric characters ASCII value 0 to 255 Default Blank CDIM Advanced Tab Setups page 1 Comm Port Security This entry does not apply to CDIMs Allowable selecti...

Страница 162: ...save or show Example Enter 0x06 0x15 Allowable selections 1 or 2 alpha numeric characters ASCII value 0 to 255 Default Blank CDIM Advanced Tab Setups page 2 DIM Parameter String Enter the desired par...

Страница 163: ...ard Euro Protocol prefix or d special Euro Protocol prefix Default S H Protocol Data Format International Option This feature is available only if there is an RS 232 or modem module installed in the c...

Страница 164: ...ity details Report Column Descriptions Contact ID This column shows the assigned numeric identifier for each contact you have set up 1 25 Contact This column lists the name of the contact entry 30 cha...

Страница 165: ...ssion then this column contains the Satellite Connect String otherwise the field is empty EMail Address This column lists the E Mail Address of the Contact Entry If a Contact needs E Mail messaging ca...

Страница 166: ...numeric characters Default selection empty Control Buttons lower right of screen Save If editing a contact touch this button to save the current record entries to the database It will not clear the sc...

Страница 167: ...ric string maximum 40 characters Default selection empty Modem COM Port This field allows the Modem assignment to the current contact The setup of a modem will be done in the Comm Devices Setup area S...

Страница 168: ...button to save the current record entries to the database It will not clear the screen If adding a contact s modem information touch this button to save the new entry s record to the database and clea...

Страница 169: ...ble if a fax modem card is installed in the console Fax Number Enter the phone number of the contact s fax machine Allowable selection 40 character maximum Default selection Empty Fax Modem COM Port S...

Страница 170: ...s button to save the current record entries to the database It will not clear the screen If adding a contact s fax information touch this button to save the new entry s record to the database and clea...

Страница 171: ...an Ethernet Comm Device is installed in the console Remote TCP IP Address Enter the remote host s TCP IP address Allowable selection IP Address Formatted XXX XXX XXX XXX where XXX is 0 to 255 OR also...

Страница 172: ...screen Save If editing a contact s TCP IP information touch this button to save the current record entries to the database It will not clear the screen If adding a contact s TCP IP information touch t...

Страница 173: ...llite Comm Device is installed in the console Satellite Conn String Enter the current contact s Satellite connection string Allowable selection Alpha Numeric maximum 30 characters Default selection Em...

Страница 174: ...tries to the database It will not clear the screen If adding a contact s Satellite information touch this button to save the new entry s record to the database and clear the screen ready for a new add...

Страница 175: ...50 characters Default selection Empty Control Buttons lower right of screen Save If editing a contact s email information touch this button to save the current record entries to the database It will...

Страница 176: ...assigned Automatic Event Activities that have occurred Report Column Descriptions Event Time This column shows the date and time when the task is triggered Event ID This column shows the assigned nume...

Страница 177: ...hich you can choose from a variety of filtering options These filtering options let you select automatic event records from All Tasks Device Tasks Print Tasks and Auto Connect tasks They are also used...

Страница 178: ...esis towards the edge of the column If you want to find out more details on such a record you will have to touch the Edit Task button to view the devices actions assigned to that task Each row task in...

Страница 179: ...the Device Label that is involved in performing the function When a Contact is involved in the Automatic Action it represents the Device used and Format of the Data to be transmitted e g Computer TCP...

Страница 180: ...involve many combinations of Reports or Actions Times Events Contacts and Connection Modes Any record containing more selections than can fit in the column s width will have an ellipsis inside a paren...

Страница 181: ...right of screen Add Task Touch this button to add a new Device task Edit Task You select a Task Record entry and then touch this button to edit the task Delete Task You select a Task Record entry and...

Страница 182: ...y open and the event happens the relay will change to closed When the event clears the relay will go back to open its normal state as per setup Touch this button to the select the event s from the dro...

Страница 183: ...sks can involve many combinations of Reports or Actions Times Events Contacts and Connection Modes Any record containing more selections than can fit in the column s width will have an ellipsis inside...

Страница 184: ...ght of screen Add Task Touch this button to add a new print task Edit Task You select a Task Record entry and then touch this button to edit the task Delete Task You select a Task Record entry and the...

Страница 185: ...ly by Day of Week Annually by Day of Month Monthly by Day of Week Monthly by Day of Month Weekly Daily Default selection Weekly Month Allowable selections January December Default selection January We...

Страница 186: ...the drop down lists that will trigger the new task Alarms Notifications External Inputs Default Field is empty Printer Field Select a Printer from the dropdown list of available printers Default Inter...

Страница 187: ...ents Contacts and Connection Modes Any record containing more selections than can fit in the column s width will have an ellipsis inside a parenthesis towards the edge of the column If you want to fin...

Страница 188: ...anager Connection Mode This column lists the device used and format of the data to be transmitted Co 1 Modem 1 Label Control Buttons on right of screen Add Task Touch this button to add a new task Edi...

Страница 189: ...the Add Task button will display an error message indicating that a task must be deleted before another can be added Time Field Touch this button to select a time frequency for the new task Period Al...

Страница 190: ...nnect method Possible selections Computer mode auto connect methods Modem TCP IP or Satellite Non computer mode auto connect methods Fax or E Mail Default Modem Report Field Non Computer Mode Only Sel...

Страница 191: ...ters This feature allows you to choose whether or not to calculate Business Inventory Reconciliation BIR volumes using the Temperature Compensation TC value Select No the default if the meters are not...

Страница 192: ...etwork You can also display printer status and show jobs in printer queues Use the Get Printers button to locate available printers or enter a URI Uniform Resource Identifier field as described below...

Страница 193: ...listed in the Printer drop down list Set the Is Default field to Yes or No The default printer is the first to display when you touch the Print Button on the top of the screen Enter a Label for the p...

Страница 194: ...int Button on the top of the screen Enter a Label for the printer The console will display this label when you Print display the Printer Status or display Print Jobs Set the Driver Selection field to...

Страница 195: ...he Label assigned to this printer when it was added in the Printer Setup screen Note The name TLSIntegralPrinter and the PRINTER 1 screen number are assigned to the integral printer which is installed...

Страница 196: ...btained from the software driver associated with the printer so it may be generic in nature State The current printer state for example Printing a Job Stopped State Reasons Any message that may be ass...

Страница 197: ...tification number assigned by the console to the print job Start Time The time the job started State The current state of the job for example Pending Processing Stopped Canceled etc Printer The name a...

Страница 198: ...touching the alarm bell icon in a device s graphical display Tank Status Detail and Sensor Status screens Once in this screen touching the Alarm Access button again will acknowledge all unacknowledge...

Страница 199: ...cleared will appear in the Active Alarm List if the alarm has not yet been acknowledged Active Alarm Report Screen Refresh Rate The active alarm data will be updated upon change of state Control Butt...

Страница 200: ...default view is the 100 most recent alarm events Report Column Descriptions This column lists the device code followed by device iteration number e g T1 This column will be blank for system alarms tha...

Страница 201: ...isplays the cause of the selected alarm and the console s standard alarm corrective action If custom alarm help has been enabled and custom information entered for this alarm the custom information wi...

Страница 202: ...ts the device code followed by device iteration number e g T1 This column will be blank for system alarms that are not device specific Label This column lists the label of the device that is in alarm...

Страница 203: ...alarm and the console s standard alarm corrective action If custom alarm help has been enabled and custom information entered for this alarm the custom information will be displayed with a link to the...

Страница 204: ...the 100 most recent alarm warning events Report Column Descriptions This column lists the device code followed by device iteration number e g T1 This column will be blank for system alarms that are no...

Страница 205: ...isplays the cause of the selected alarm and the console s standard alarm corrective action If custom alarm help has been enabled and custom information entered for this alarm the custom information wi...

Страница 206: ...the capabilities of the probe the column headings will print but the field will be blank e g Water Height for probes that do not have a water float In the All Tanks view where it is possible that a si...

Страница 207: ...00 Allowable range 0 to 264 172 gal 0 to 999 999L Ullage xx The User defined ullage is only displayed if defined in All Tank setup Allowable range 0 to 264 172 gal 0 to 999 999L Fuel Height Allowable...

Страница 208: ...sible configurations are daily at shift close if enabled at day close if enabled through Variance Analysis or hourly configurations at specific time of day with interval set from every 1 to 24 hours R...

Страница 209: ...the probe does not measure density and if TC density is not enabled Allowable range 42 139 to 56 185 lbs ft3 675 00 to 900 00 kg m3 Fuel Height Allowable range 0 to 390 0 in 0 to 9906 0mm Water Height...

Страница 210: ...for the start of the shift The second line displays data at the shift close for a closed shift or at a time when Shift Report is selected for the current shift The Shift inventory data will be refresh...

Страница 211: ...ge 0 to 264 172 gal 0 to 999 999L Ullage xx The User defined ullage is only displayed if defined in All Tank setup Allowable range 0 to 264 172 gal 0 to 999 999L Delivery Volume A Delivery Volume entr...

Страница 212: ...ect SLD and Continuous Statistical Leak Detection CLSD test results on one report This is a historic report and displays only results with a status of Passed There are several categories of results th...

Страница 213: ...o 999 999L Volume Allowable range 0 0 to 100 0 Control Buttons on right of screen Tank Test Setup Touch this button open the Tank Setup Environmental Test screen Regulatory Compliance Note In tank lea...

Страница 214: ...Type First Annual First 0 1 gph 0 38 lph test passed for a given month First Periodic First 0 2 gph 0 76 lph test passed for a given month Last Annual Last 0 1 gph test passed Last Gross Last 3 0 gph...

Страница 215: ...l be only one entry of Gross test history per line Allowable entries 0 to 672 Gross Test Since Midnight This column lists the number of gross tests passed since midnight This column is for Gross tests...

Страница 216: ...s normal If there are any active sensor alarms they will be displayed on this screen At most there will be only 1 line per sensor either showing the sensor in alarm or in a normal condition Since this...

Страница 217: ...e Possible messages depending on sensor type Normal Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm Low Liquid Alarm Liquid Warning Setup Data Warning Communication Alar...

Страница 218: ...gured and selected sensor If a Sensor has no Alarms during the selected time period then there will be one record with no Active Time showing a Normal status for that sensor Screen Title Bar The top r...

Страница 219: ...Low Liquid Warning Low Liquid Alarm Temperature Warning Relay Active Install Alarm Active Time Active time is the alarm post time This column entry is blank if the device is in a normal status Clear...

Страница 220: ...Date Range Date From and Date To only All Records Period range Previous Previous n selections Number of Period option selections Weeks 1 to 156 Months 1 to 36 Years 1 to 3 Default selections Previous...

Страница 221: ...selected in Delivery Setup is Manual Units are as selected in Display Setup Language Units Report Column Descriptions Tank This column lists the configured tank label Volume This column displays the...

Страница 222: ...e the Start button is touch to record the Delivery there will be a 30 minute timeout period after which the Delivery will be declared ended in case you forget to manually stop the Delivery Start manua...

Страница 223: ...s line contains date tank data recorded at the start of the delivery End This line contains date tank data recorded at the end of the delivery Amount delivered This line contains the difference betwee...

Страница 224: ...ure density Allowable range Depends on tank volume and fuel density Fuel Density This column will not display if the probe does not measure density Allowable range 42 139 to 56 185 lbs ft 3 675 00 to...

Страница 225: ...tank data recorded at the start of the delivery End This line contains date tank data recorded at the end of the delivery Amount delivered This line contains the difference between the start of deliv...

Страница 226: ...lowable range 42 139 to 56 185 lbs ft 3 675 00 to 900 00 kg m3 Fuel TC Density This column will not display if the probe does not measure density and if TC density is not enabled Allowable range 42 13...

Страница 227: ...mn is not selectable When the delivery in progress has completed the In Progress record will be replaced with the delivery end date and time and data Displayed volumes will be Standard Volumes if TC T...

Страница 228: ...column displays any entered delivery identification Control Button on right of screen Edit Record NOTE At least a single row of data must be present and selected before the Edit Record button is acti...

Страница 229: ...d tank Touch the Back button to return to Ticketed Delivery screen Delivery End Time Date and time delivery ended Tank This is a read only field showing the Tank receiving the delivery Measured Delive...

Страница 230: ...eric characters Delivery ID Delivery identification entry Allowable selection Up to 20 alpha numeric characters Control Button on right of screen Previous Record Touch this button to populate the Edit...

Страница 231: ...elivery record for the selected tank Touch the Back button to return to Ticketed Delivery screen Delivery End Date Date delivery ended Delivery End Time Time delivery ended Tank This is a read only fi...

Страница 232: ...Volume Visible only if TC Volume is selected for TC Ticketed Delivery in Delivery Setup Delivered volume as entered from the delivery ticket Allowable selection 0 to 264 172 gal 0 to 999 999 liters B...

Страница 233: ...as selected in Display Setup Language Units Report Column Descriptions Start Date Delivery Start Date and Time MM DD YYYY HH MM default format End Date Delivery End Date and Time MM DD YYYY HH MM def...

Страница 234: ...Adjusted Delivery Temperature compensated volume delivered NOTE This column only visible if Temperature Compensation is enabled ref Tank Setup All Tanks Control Button on right of screen Select Range...

Страница 235: ...esterday Weekly Reports start the week on the day of the week set up in Inventory Setup Inventory Report Times tab The current week report will always be a partial report The previous week report is a...

Страница 236: ...ventory This column contains the calculated ending inventory derived from the measured starting volume minus reported sales plus measured deliveries Gauged Inventory This column contains the measured...

Страница 237: ...een A Status tab displays the current status that impacts reconciliation data A Reconciliation tab displays all records with Metered Sales Variance and a reason s for the variance More Touch this butt...

Страница 238: ...ange By Single Date Using Day Month Year Single Date picker By Week Range Using Week Year From To Picker By Month Range Using Month Year From To Picker N Periods By Date Range Using Day Month Year Fro...

Страница 239: ...revious Rolling Report starts N 1 days ago and runs to the day before yesterday Weekly Reports start the week on the day of the week set up in Inventory Setup Inventory Report Times tab The current we...

Страница 240: ...s reported sales plus ticketed deliveries Gauged Inventory This column contains the measured inventory at the end of the reconciliation period Variance This column contains the difference between calc...

Страница 241: ...th 2 If Summary Period in Reconciliation Setup is Rolling Current Displayed as Current Filter 1 Show Records and Summaries Shift a Select Range By Single Date Using Day Month Year Single Date picker B...

Страница 242: ...Reconciliation Test Report This screen contains Reconciliation Variable Threshold test results Report Column Descriptions End Date Date of test Threshold Type Disabled Monthly Rolling Day Daily Rollin...

Страница 243: ...e of screen More Touch this button to cause the Reconciliation Test Report screen to scroll to the right displaying columns and data that are hidden on the right and are not displayed in the data area...

Страница 244: ...tures to the site s current and historical tank and line test results Also from Diagnostic screens you can manually run tank tests PLLD line tests and view technical data from monitored devices Detail...

Страница 245: ...no history Siphon manifolded tanks are treated as one tank in CSLD The tanks in the manifolded set share the same results Tanks that are not configured do not have CSLD enabled or are configured with...

Страница 246: ...0 seconds Regulatory Compliance Note In tank leak tests will not be declared a PASS unless the product level in the tank satisfies the minimum product level defined in our Third Party certification fo...

Страница 247: ...ded tanks are treated as one tank in CSLD The tanks in the manifolded set share the same table and results Deleting the table for any tank within the set will in effect delete the table of all the mem...

Страница 248: ...C Temp Rate Note The Temp rate field does not use the offset factor 32 for conversion of C to F Value range 40 0 to 99 9 F hour 22 2 to 55 5 C hour Disp Factor Value range 0 to 264 172 gal 0 to 999 99...

Страница 249: ...the report view is unchanged If the Clear Table button is selected when the current tank selection is All Tanks the following error message is displayed This operation is valid for a single tank only...

Страница 250: ...as one tank in CSLD The tanks in the manifolded set share the same table and results Deleting the table for any tank within the set will in effect delete the table of all the members in the set All t...

Страница 251: ...Tank s Select tank s to report All Tanks or Current Tank CSLD Test Setup Touch this button open the Tank Setup CSLD Test Setup screen Regulatory Compliance Note In tank leak tests will not be declare...

Страница 252: ...tanks or a specific tank NOTE Tanks must have the SLD Environmental Test Method enabled Report Column Descriptions The SLD Last Test report columns contain the following information depending on test...

Страница 253: ...o short Zone Temp Chg one or more in fuel thermistors changed too much Leak Rate Value range 26 42 to 26 42 gal 99 99 to 99 99 L Hours Value range 0 0 to 24 0 blank for gross test Tank Volume Value ra...

Страница 254: ...are displayed after the first period of the test 15 minutes for gross tests or 30 minutes for precision tests Tanks must have SLD enabled and be configured with a probe that supports leak detection to...

Страница 255: ...and water floats Percent Vol Too Low tank volume too low Product Level Increase leak rate is excessively positive Recent Delivery test started too soon after delivery SLD Float size too small fuel fl...

Страница 256: ...ate The SLD Test In Progress Report data will be refreshed every 30 seconds Test Control Buttons on right of screen Setup Touch this button to open the Tank Setup SLD Test Setup screen Manual Test Tou...

Страница 257: ...when an SLD Test is active 2 Tank tests will unavailable for tanks that do not have SLD enabled have an un configured probe or are configured with a probe that does not support leak detection Test Ru...

Страница 258: ...a manual test of a selected tank This button is disabled if tests are running for the currently selected tank or if Start All Tanks is selected to start tests for all tanks Stop Touch this button to...

Страница 259: ...test and all Pass and Fail records of precision tests Invalid results are not displayed in this screen Tanks must have SLD enabled and be configured with a probe that supports leak detection to be vis...

Страница 260: ...this button to setup the report s contents Select Option List Select data for report All Records Day Week Month Year Date Range Period Option List Select period Previous Previous n selections Select...

Страница 261: ...st times assuming no dispense which would restart the test s after the dispense and no thermals are 3 0 11 3 several minutes 0 2 0 76 30 minutes and 0 1 0 38 45 minutes 3 A 3 0 11 3 test runs that tes...

Страница 262: ...ual Test screen is updated for every 30 seconds for change of test or line state Test Control Buttons on right of screen Start Touch this button to start a manual test of all lines or an Individual Li...

Страница 263: ...eport Column Descriptions PLLD line identifier Device code followed by 1 to 32 e g Q1 Label PLLD line label Label assigned in setup Dispensing flag Enabled Disabled Test Status Possible messages inclu...

Страница 264: ...Off Pressure measured on line Value range 14 000 to 99 999 psi 96 485 to 689 173kPa PLLD Status Refresh Rate The PLLD Status screen will be refreshed every 4 seconds Control Buttons right of screen S...

Страница 265: ...last five 3 0 gph 11 3 lph test results including passed and failed tests for all lines with PLLD Report Column Descriptions Date Time The Date and Time of the test Pump On The pressure reading when...

Страница 266: ...Value range 14 0 to 99 9 psi 96 5 to 689 2kPa Status Possible messages Pass Fail High Pressure Control Buttons right of screen Setup Touch this button to open the PLLD Setup Pump and Line Setup PLLD...

Страница 267: ...mid range test results including passed and failed tests for all lines with PLLD Report Column Descriptions Date Time Value range The Date and Time of the test Pump On The pressure reading when turni...

Страница 268: ...nge test Value range 14 0 to 99 9 psi 96 5 to 689 2kPa Status Possible messages Pass Fail Control Buttons right of screen Setup Touch this button to open the PLLD Setup Pump and Line Setup PLLD screen...

Страница 269: ...mation about all lines with PLLD in the system This screen will only be available if the 0 2 gph 0 76 lph or 0 1 gph 0 39 lph line leak test features are available Report Column Descriptions PLLD line...

Страница 270: ...ts Number of total tests run Value range 0 99 Control Buttons right of screen Setup Touch this button to open the PLLD Setup Pump and Line Setup PLLD screen Diagnostics line pressure sensor Touch this...

Страница 271: ...ort with the last five 0 2 gph 0 76 lph test results including passed and failed tests for all lines with PLLD This screen will only be available if the 0 2 Line Leak Test feature is available Report...

Страница 272: ...lue range 0 00 to 99 99 Duration Test Duration in hours and fraction of an hour in minutes Long durations indicate there was a lot of thermal activity during the test Value range HH MM where HH 0 to 9...

Страница 273: ...rt with the last five 0 1 gph 0 38 lph test results including passed and failed tests for all lines with PLLD This screen will only be available if the 0 1 Line Leak Test feature is available Report C...

Страница 274: ...lue range 0 00 to 99 99 Duration Test Duration in hours and fraction of an hour in minutes Long durations indicate there was a lot of thermal activity during the test Value range HH MM where HH 0 to 9...

Страница 275: ...ms with several console features such as CSLD ISD etc This report shows the last 46 inventory samples For the All Tanks view if some probes measure temperature and others do not The Avg Temp Top Temp...

Страница 276: ...ompensation the standard volume will be displayed Value range 0 00 to 264 172 00 gal 0 00 to 999 999 99L Height Value range 0 to 390 000 in 0 to 9906 000mm Avg Temp Value range 40 00 to 140 00 F 40 00...

Страница 277: ...ed meter start stop events Date Time Date time of start or stop meter event Fuel Position Fueling position reported by the POS terminal Meter Meter number reported by the POS terminal User FP Fuel pos...

Страница 278: ...Volume Volume dispensed as reported by the POS terminal with stopped meter event Control Button Right side of Screen Clear All The Clear All button is only enabled when at least one record is availab...

Страница 279: ...s is the screen you want to use to verify meter mapping or to view if the site should go unmapped suspending BIR Source DIM module connected to reporting POS terminal User FP Fuel position as labeled...

Страница 280: ...d record will populate the appropriate fields in the Edit Tank Map dialog When the Tank Map record has been edited using the Edit Tank Map dialog the new data will replace the old data in the selected...

Страница 281: ...his button to lock all entries in the tank map Unlock All This button is grayed out unless at least one record is in the data view area Touch this button to unlock all entries in the tank map Clear Al...

Страница 282: ...entify post blend metering This screen displays active events as they are reported by the POS terminal Report Column Descriptions Transaction Time Date time of transaction Real FP Fueling position rep...

Страница 283: ...ocked field is inactive Touch the Down arrow to select Yes or No Tank Blend Touch the Down arrow to select Tank Label Blend Label Unmapped Probeless or R retired User FP Fuel position as labeled by th...

Страница 284: ...ut alarm setup issues Any dim alarms All tanks will be set DIM missing starts or stops Set when a fake start or fake end event is generated A fake start indicates we received an end event but no start...

Страница 285: ...ater height from the previous close is greater then the current water height Set per individual tank Power outage Always get set on power up or system reset All tanks will be set Tank Chart Change ind...

Страница 286: ...culated daily as follows Computed Daily end volume Start volume total sales deliveries Daily variance Computed daily end volume measured end volume 2 Daily sales and variances are totaled over the def...

Страница 287: ...e Set when any dim events received and one of the tanks is not mapped All tanks will be set Meter map unstable changes during period Any time the meter map table is changed reset clear unlock lock map...

Страница 288: ...the report over right or left to reveal additional columns outside of the data view area BIR Report Touch this button to view the daily record Reconciliation Report for the selected product Select Ran...

Страница 289: ...he Probe Diagnostics General screen displays a report with general information about each probe Report Column Descriptions Type Probe Type Description e g Mag 1 Code Circuit Code Hex number Value rang...

Страница 290: ...ar Week Value range YY 0 52 Rev Revision Number Value range 00 to 99 Gradient Probe Gradient Value range 0 000 to 999 999 Probe Diagnostics General Screen Refresh Rate The General Probe Diagnostics da...

Страница 291: ...ence Distance screen displays a report with Original and Current Reference distances for each probe Report Column Descriptions Type Probe Type Description e g Mag 1 Serial No Probe Serial Number Value...

Страница 292: ...ence Distance Reading Date Value Year month and day Current Reference Current Reference Distance Reading Value 0 00 to 390 00 in 0 00 to 9906 00mm Probe Diagnostics Reference Distance Screen Refresh R...

Страница 293: ...g Mag 1 Probe serial number up to 7 digits Date and time time channel data was received Channel Data Label for the Channel Section Channel data Hex number is read from the report as shown in the exam...

Страница 294: ...n Screens Manual 283 Probe Diagnostics Channel Refresh Rate The Probe Diagnostics Channel data will be refreshed every 5 seconds Control Button right of screen Probe Setup Touch this button open the D...

Страница 295: ...Mag Options screen displays a report with options supported by Mag Probes Report Column Descriptions Low Temp Indicates whether or not the probe supports the low temperature option Possible messages...

Страница 296: ...ot the probe supports the leak 0 2 gph 0 76 lph option Possible messages Yes No Leak 3 0 11 3 Indicates whether or not the probe supports the leak 3 0 gph 11 3 lph option Possible messages Yes No Prob...

Страница 297: ...Probe Diagnostics Communication screen displays a report with communication health and status parameters for each probe Report Column Descriptions Type Probe type e g Mag 1 Status Probe Status Possib...

Страница 298: ...s Value range 0 to 999999 Partial Number of partial errors Value range 0 to 999999 Comm Errors Number of comm errors Value range 0 to 999999 Probe Diagnostics Communication Refresh Rate The communicat...

Страница 299: ...y tests are available 1 Sequential Test This test sets selected relays to INACTIVE for two seconds and then sets them to ACTIVE for two seconds When the test is complete the relays are automatically r...

Страница 300: ...y type Possible messages include STANDARD The On Off state is determined by assigned alarms warnings MOMENTARY The On Off state is determined by assigned alarms warnings However relay returns to the i...

Страница 301: ...inish Test button is still grayed out The Test Relays button will be grayed out used for sequential testing only 2 Start the Test After all the relays required for the test have been selected checked...

Страница 302: ...ernal Inputs Diagnostics External Inputs screen displays a report with diagnostic information about each external input Report Column Descriptions External input identifier External Input Identifier V...

Страница 303: ...state Value range 0000 to 9999 days plus hh mm ss e g 00001 03 05 48 Type The External Input type Possible messages Standard Generator Pump Sense Standard ACK External Input Diagnostic Screen Refresh...

Страница 304: ...Diagnostics Liquid screen displays a report with information about each Liquid Sensor Report Column Descriptions Type Sensor Type Description Possible messages Tri State Single Float Normally Closed...

Страница 305: ...lue Resistance value Value range 0 to 1000000000 Status Sensor Status Possible messages Normal Unknown Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm...

Страница 306: ...Vapor screen displays a report with information about each Vapor Sensor Report Column Descriptions Category Sensor Category Description Possible messages Other Sensors Annular Dispenser Pan Monitoring...

Страница 307: ...ion Value range 0 to 999999999 Status Sensor Status Possible messages Normal Unknown Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm Low Liquid Alarm...

Страница 308: ...undwater screen displays a report with information about each Groundwater Sensor Report Column Descriptions Category Sensor Category Description Possible messages Other Sensors Annular Dispenser Pan M...

Страница 309: ...le messages Normal Unknown Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm Low Liquid Alarm Liquid Warning Sensor Diagnostics Groundwater Sensor Refre...

Страница 310: ...CL screen displays a report with information about each Type A 2 Wire CL Sensor Report Column Descriptions Type Sensor Type Description Possible messages ULTRA 2 Discriminating Interstitial Category S...

Страница 311: ...alue in microamps Status Sensor Status Possible messages Normal Unknown Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liquid Alarm Low Liquid Alarm Liquid Warnin...

Страница 312: ...reen displays a report with information about each Type B 3 Wire CL Sensor Report Column Descriptions Type Sensor Type Description Possible messages Ultra Z 1 4Site Pan Sump Standard Ultra Z 1 HV 4Sit...

Страница 313: ...amps Value 2 Resistance value Value range 0 to 1000000000 Status Sensor Status Possible messages Normal Unknown Setup Data Warning Fuel Alarm Out Alarm Short Alarm Water Alarm Water Out Alarm High Liq...

Страница 314: ...Diagnostics General screen displays a report with general diagnostic information about all Mag Sensors Report Column Descriptions Type Sensor Type Description Possible messages 059 MAG Sensor Status...

Страница 315: ...0 to 1219 20mm Total Height Absolute liquid height as measured by the Mag Sensor Value range 0 00 to 48 00 in 0 00 to 1219 20mm Fluid Temp Temperature of the fluid in which the Mag Sensor is submerged...

Страница 316: ...screen displays a report with communication diagnostic information about all Mag Sensors Report Column Descriptions Samples Read Number of Samples Read Value range 0 to 4294967295 Samples Used Number...

Страница 317: ...rors Number of Comm Errors Value range 0 to 999999 Restarts Number of Restarts Value range 0 to 999999 Mag Sensor Diagnostics Comm Screen Refresh Rate The Mag Sensor Diagnostics Comm data will be refr...

Страница 318: ...cs Constants screen displays a report with constants diagnostic information about all Mag Sensors Report Column Descriptions Serial Number Mag Sensor Serial Number Value XXXXXXX Model Mag Sensor Model...

Страница 319: ...0 in 2 5 to 3657 6mm Max Threshold Mag Sensor Maximum Threshold Value range 0 1 to 144 0 in 2 5 to 3657 6mm Num Floats Mag Sensor Number of Floats Possible messages 1 2 Temp Mag Sensor Temperature Ena...

Страница 320: ...ensor number e g 1 and label e g Mag Sensor 1 Mag Sensor serial number up to 7 digits Date and time time channel data was received Channel data Hex number is read from the report as shown in the examp...

Страница 321: ...s Manual 310 Mag Sensor Diagnostics Channel Screen Refresh Rate The Mag Sensor Diagnostics Channel data will be refreshed every 8 seconds Control Buttons right of screen Setup Touch this button open t...

Страница 322: ...ral screen displays a report with general diagnostic information about all Line Pressure Sensors in the system This screen is reached by selecting the Line Pressure Sensor icon in the diagnostic main...

Страница 323: ...89 173kPa Diagnostics LPR Sensor General screen refresh rate The LPR Sensor Diagnostics General data will be refreshed every second Control Buttons right of screen More Touching the More button will s...

Страница 324: ...ation screen displays a report with communication diagnostic information for all Line Pressure Sensors Report Column Descriptions Samples Read Number of Samples Read Value range 0 to 4294967295 Sample...

Страница 325: ...PR Sensor Comm screen refresh rate The LPR Sensor Diagnostics Communication data will be refreshed every 8 seconds Control Buttons right of screen More Touching the More button will shift the report o...

Страница 326: ...lays a report with constants diagnostic information about all Line Pressure Sensors in the system Report Column Descriptions Serial Number Line Pressure Sensor Serial Number Value XXXXXXXXXX Model Lin...

Страница 327: ...alue range 0 to 65535 Control Buttons right of screen More Touching the More button will shift the report over right or left to reveal additional columns outside of the data view area Setup Touch this...

Страница 328: ...nsor Diagnostics Channel screen displays a report with channel diagnostic information about all Line Pressure Sensors Report Description Each Line Pressure Sensor s channel data is preceded by the fol...

Страница 329: ...l 0 is B610 for Channel 3 it is 0235 and for channel 16 it is 00A1 Data Type Hexidecimal Value range 0000 to FFFF Diagnostics Line Pressure Sensor Channel screen refresh rate The Line Pressure Sensor...

Страница 330: ...I and have actionable messages will appear in this report Messages will be generated by AccuChart II and added to this list AccuChart II will also decide when existing messages should be changed or re...

Страница 331: ...s percentage of sales volumes A separate button gives you a report of Delivery variances made using both charts within the selected calibration period Report Column Descriptions Open Date Time Start t...

Страница 332: ...me Ordered Delivery Comparison in the title bar and displays the following columns End of Delivery Date Time Chart label Delivery Variance Chart label Delivery Variance Delivery variance is calculated...

Страница 333: ...ross the full range of the tank no error Control Buttons Right side of screen Comp Touching the Compare button will show the Select Charts to Compare dialog You select the tank charts to compare from...

Страница 334: ...across the full range of the tank no error Control Buttons Right side of screen Comp Touching the Compare button will show the Select Charts to Compare dialog You select the tank charts to compare fr...

Страница 335: ...calibration will clear these alarms except where noted To minimize the risk of false premature alarms no warnings will be posted until Automatic AccuChart II has been running for at least 48 hours In...

Страница 336: ...nd the search algorithm hits a boundary Station too busy Warning will be posted when the average number of records generated per day is less than N and the throughput is above a threshold T No Success...

Страница 337: ...n the Tank Setup AccuChart II screen Only tanks that are actively running AccuChart II will have tank buttons on the bottom of the screen Data Sufficiency This read only field contains the current per...

Страница 338: ...t data in bottom half of tank Station Too Busy Temporarily halt dispensing to introduce more idle periods The list of possible action messages in the Sufficiency Improvement Action field includes Stop...

Страница 339: ...re details Report Column Descriptions Address This column contains the physical address of the module B1 S4 Master 450 slot 4 module bay behind right door Slot 1 Comm slot 1 comm bay behind left door...

Страница 340: ...column contains the date the console was factory programmed Firmware Revision This column contains the revision level of the console s firmware This column will be blank for all Comm Cards SW Build D...

Страница 341: ...the device e g B1 S1 Universal Sensor Module B1 S1 4 device connected to terminal 4 of the USM in slot 1 Type This column contains the device type e g Universal Sensor Module Mag Probe etc Serial Numb...

Страница 342: ...be blank if everything is OK If the device is a module an M will show up first If there is an error it will be indicated by followed by a reason code If possible other fields will be flagged with the...

Страница 343: ...e the console is not populated or recognized by the system type will be None 2 If a device position on a module is not populated or recognized by the system type will be None Primary Assignment This c...

Страница 344: ...on modules Report Column Descriptions Comm Number This column contains the comm card number e g Co 1 Slot This column contains the comm bay slot and module port of the installed comm card e g S1 P2 Sl...

Страница 345: ...eset Break Interrupts This column contains the number of break interrupts since the counter was reset Counter Reset Date and Time This column contains the date and time you last reset this card s coun...

Страница 346: ...ets you check for and install newer firmware for each of these modules see procedure below Report Column Descriptions Address This column contains the physical address of the device e g B1 S1 Module T...

Страница 347: ...the check box beside any module that qualifies for upgrade firmware see Available Firmware Revision paragraph above 2 The Confirm Download dialog box appears Touch the OK button Note Once the download...

Страница 348: ...tic end cap from the USB Adapter and Insert the i button in the adapter as shown in the diagram below 2 Replace the plastic retaining cap on the adapter after inserting the i Button 3 Plug the USB Ada...

Страница 349: ...TLS 450 Setup and Operation Screens Manual 338 6 Disconnect the Printer s USB cable from its connector on the CPU board and insert the USB Adapter into the CPU connector see below...

Страница 350: ...r 9 Turn on power to the console and follow the required Software Maintenance procedures When you have completed the Software Maintenance procedure s reverse the steps 4 through 7 above to remove the...

Страница 351: ...nd recover operations For ultimate protection against possible loss of data and to protect against system crashes run the Backup operation daily NOTE It is very important that you keep the V R Code Fe...

Страница 352: ...has completed Revert To Previous Software Version Button A copy of the previous older system software and databases is stored on your console s CF card If the current newer version of system software...

Страница 353: ...d in the Feature Status columns Multiple updates may be selected The List Updates button will requery for available updates and provide a list in the Feature column When the list is acquired a check w...

Страница 354: ...rogress Possible messages include Reading Update List Waiting Selection Downloading Feature Touch the boxes beside each of the desired items in this column If you change your mind about a selection to...

Страница 355: ...then touch the Install button on the right side of the screen 2 Touch the OK button on the System Restart dialog box or touch Cancel to abort the installation or to reselect the feature s you want to...

Страница 356: ...installed Multiple features may be installed concurrently Touch the boxes beside each of the desired items in this column If you change your mind about a selection touch the box again to remove the ch...

Страница 357: ...ab screen displays important information about your console s software version and installed features If you should be experiencing problems with the console please have the information on this screen...

Страница 358: ...d Edit Line Control Region The region has the following buttons from left to right touch this button to toggle between the Enhanced Numeric and Alpha keypad interfaces It is enabled when the field is...

Страница 359: ...l entries Character Entry Region This region has Buttons that enter characters in the Field Edit Line The Sp button enters a Space Character Control Region The region has the following buttons from le...

Страница 360: ...ntire entry Back touch this button to remove a character to the left of the cursor OK touch this button to apply the selection Cancel touch this button to discard any selections that have been made to...

Страница 361: ...TLS 450 Setup and Operation Screens Manual 350 Report Range Selection Dialogs The dialog boxes used to define a report s content are shown below...

Страница 362: ...e to a qualified Veeder Root Service Representative Attempting to service tank monitors and equipment without proper training can cause damage to property environment resulting in personal injury or d...

Страница 363: ...strict the probe s measurement capability PLLD Yearly A Owner or Station Attendant 1 Check submersible pump head for leakage at PLLD transducer port and functional element with pump On 2 Check PLLD tr...

Страница 364: ...d on field wiring 2 Replace sensor cable if cracked or damaged ref item A 1 Vapor Sensor Yearly A Owner or Station Attendant 1 Inspect sensor cable for any cracking or damage B Service Contractor 1 Ve...

Страница 365: ...larm in both conditions replace the sensor 2 Verify epoxy kits have been installed on field wiring 3 Replace sensor if cable is cracked or damaged ref item A 1 Mag Sensor Yearly A Owner or Station Att...

Страница 366: ...etary 1 7 No 330404 001 330435 Schlumberger CDIM 1200 Even 7 2 2 5 No 330404 002 331274 Schlumberger SAM CDIM 4800 Odd 7 1 No 331001 002 349753 Gasboy RS422 LDIM 9600 None 8 1 331001 003 349753 Gasboy...

Страница 367: ...eld precision is hundredths thousandths default C Cumulative field precision is hundredths thousandths default TOKHEIM 67A B T Blender only site collects only blender messages R Send captured message...

Страница 368: ...arameter Definitions BAUD PARITY STOP BITS DATA BITS CONVERSION STRING RATE STRING TYPE STRING BITS STRING BITS STRING UNITS B9 9600 N None H 1 V 7 G Gallons B4 4800 E Even S 2 D 8 M Metric B2 2400 O...

Страница 369: ...data that controls available features ILS Interstitial Level Sensor ISD In Station Diagnostics LVDIM Low Voltage Dispenser Interface Module MAG MAGnetostrictive technology MDIM Mechanical DIM PLLD Pre...

Страница 370: ...STP Submersible Turbine Pump USB Universal Serial Bus Regulatory Acronyms ATEX Europe BASEEFA UK C of C Certificate of Compliance CAPCO The California Air Pollution Control Officers Association CARB C...

Страница 371: ...and their vapors are extremely explosive if ignited FLAMMABLE Fuels and their vapors are extremely flammable TURN POWER OFF Live power to a device creates a potential shock hazard Turn Off power to t...

Страница 372: ...nd Water Sensor Hose h Hose Hose Hydrocarbon Sensor Hy HydcSns Hydrocarbon Sensor Line Ln Line Line Line Pressure Sensor PLLD Pl LPSensr Line P Sensor Liquid Sensor L Liquid Liquid Sensor Mag Sensor M...

Страница 373: ...nal Input Module IO IOM Relay External Input Module Table of Standard Abbreviations Word English Abbreviation Alarm Alrm Average Avg Board brd Dispense Disp Delivery dlvy or dlv Evaporation Evap Facto...

Страница 374: ...m Millimeter mm Degrees Fahrenheit F Degrees Celcius C Pounds per Square Inch psi Pascal Pa Kilo Pascal kPa Foot ft Meter m Pound lb Kilogram kg Year yr or Y Date format Month mo Date format Day d or...

Страница 375: ...be Name Name Type Phase Sep Density Leak Detect Water Detect C000 Std 0 10 GPH 2 float MAG1 No 0 10 GPH Yes C001 Std 0 20 GPH 2 float MAG2 No 0 20 GPH Yes D000 Std Inv only 2 float MAG3 No None Yes D0...

Страница 376: ...r browser For help enabling the applet go to http www java com en download help enable_browser xml b JVM version 1 4 or newer installed To download the latest JVM version go to http java sun com j2se...

Страница 377: ...n to display the desired page Viewable pages are as follows report content is dependent on installed hardware and console features Reports Inventory current Delivery Last delivery record per tank Shif...

Страница 378: ...ults History 0 1 Test Results 0 1 Test Results History Sensors Liquid Sensor Status Alarm History Vapor Sensor Status Alarm History Groundwater Sensor Status Alarm History 2 Wire CL Sensor Status Alar...

Страница 379: ...page lets you communicate with the TLS 450 using RS 232 commands Setup This page lets you enter an access password and set page data refresh rates About This page displays your installed TLS 450 Web...

Страница 380: ...Appendix A 5 Web Access Home Page The TLS 450 Web Home page is shown below Refresh System Status Button Click on this button to refresh the report s contents applies if new data is available...

Страница 381: ...Web Access 6 Web Access Reports Inventory Page The TLS 450 Web Access Reports Inventory page example is shown below...

Страница 382: ...Appendix A 7 Web Access Reports Delivery Page The TLS 450 Web Access Reports Delivery page example is shown below...

Страница 383: ...this manual for more information on this page A Delivery Volume entry only appears if a delivery was made during the shift A Totals Volume entry only appears if a delivery was made during the shift To...

Страница 384: ...Appendix A 9 Web Access Active Alarms Page The TLS 450 Web Access Active Alarms page is shown below...

Страница 385: ...Web Access 10 Web Access Priority Alarms Page The TLS 450 Web Access Priority Alarms page example is shown below...

Страница 386: ...Appendix A 11 Web Access Non Priority Alarms Page The TLS 450 Web Access Non Priority Alarms page example is shown below...

Страница 387: ...Web Access 12 Web Access Tanks Status Page The TLS 450 Web Access Tanks Status page example is shown below...

Страница 388: ...Appendix A 13 Web Access Tanks Alarm History Page The TLS 450 Web Access Tanks Alarm History page example is shown below...

Страница 389: ...Web Access 14 Web Access Tanks Leak Test Results Page The TLS 450 Web Access Tanks Leak Test Results page example is shown below...

Страница 390: ...Appendix A 15 Web Access Tanks Leak Test History Page The TLS 450 Web Access Tanks Leak Test History page example is shown below...

Страница 391: ...Web Access 16 Web Access Lines Line Status The TLS 450 Web Access Lines Line Status page example is shown below...

Страница 392: ...Appendix A 17 Web Access Lines Alarm History Page The TLS 450 Web Access Lines Alarm History page example is shown below...

Страница 393: ...Web Access 18 Web Access Lines 0 2 Test Results Page The TLS 450 Web Access Lines 0 2 Test Results page example is shown below...

Страница 394: ...Appendix A 19 Web Access Lines 0 2 Test History Page The TLS 450 Web Access Lines 0 2 Test History page example is shown below...

Страница 395: ...Web Access 20 Web Access Lines 0 1 Test Results Page The TLS 450 Web Access Lines 0 1 Test Results page example is shown below...

Страница 396: ...Appendix A 21 Web Access Lines 0 1 Test History Page The TLS 450 Web Access Lines 0 1 Test History page example is shown below...

Страница 397: ...is shown below The Status page for liquid sensors is shown Click on the arrow beside the select sensor field to open a dropdown list of available sensors Select one to display a similar Status page fo...

Страница 398: ...hown below The Alarm History page for liquid sensors is shown Click on the arrow beside the select sensor field to open a dropdown list of available sensors Select one to display a similar Alarm Histo...

Страница 399: ...Web Access 24 Web Access BIR Current BIR Report Page The TLS 450 Web Access BIR Current BIR Report page example is shown below...

Страница 400: ...Appendix A 25 Web Access BIR Previous BIR Report Page The TLS 450 Web Access BIR Previous BIR Report page example is shown below...

Страница 401: ...Web Access 26 Web Access BIR Current Book Report Page The TLS 450 Web Access BIR Current Book Report page example is shown below...

Страница 402: ...Appendix A 27 Web Access BIR Current Book Report Page The TLS 450 Web Access BIR Current Book Report page example is shown below...

Страница 403: ...Web Access 28 Web Access BIR Test Results Report Page The TLS 450 Web Access BIR Test Results Report page example is shown below...

Страница 404: ...Appendix A 29 Web Access Diags Page The TLS 450 Web Access Diags page example is shown below This page displays information about software features installed in this TLS 450 console...

Страница 405: ...232 published commands Type in the serial command Ixxxxx e g I20200 delivery report in the field below the terminal window click Enter and the TLS 450 will display the Delivery Report in the terminal...

Страница 406: ...the Security Code Enable box in this page and enter up to a six alph numeric password in the field below Auto Refresh Page Data To automatically refresh page data click the box next to Auto Refresh C...

Страница 407: ...Web Access 32 Web Access About Page The TLS 450 Web Access About page example is shown below This page displays the version of Veeder Root s Web Access software installed in the TLS 450 console...

Страница 408: ...For technical support sales or other assistance please visit www veeder com...

Отзывы: