7
1900 - 2050
300
VVS
83
0
40
600
150
300
150
150
150
720
503,5
71,5
150
150
150
150
655
*716,5
*1
53,5
POSITIONING OF POWER SOCKETS AND WATER/DRAINAGE
HAND THIS DRAWING TO YOUR ELECTRICIAN/PLUMBER SO THAT THE SOCKETS ARE FITTED IN THE RIGHT PLACES AND THEY FIT YOUR
NEW KITCHEN.
The recommended heights for positioning power sockets
and water/drainage
are shown below.
Always check the white goods supplier’s instructions.
Electrical installations should always be carried out by a qualified electrician in accordance with applicable regulations.
TALL CABINET/BUILT-IN CABINET
Recommended heights as per the image,
but read the white goods supplier’s
instructions to check that there is no
special measurement for your
particular selection. For overhead cabinets/
top cabinets, it is important to consider the
nailing batten. For where it is positioned
for different cabinet standards, see “Total
heights of kitchen fittings”. For a built-
in oven/microwave, two sockets can be
placed behind the microwave at the
recommended height. The recommended
height for sockets above fridge/freezers
with overhead cabinets is C-C 50 mm
above the fridge/freezer. The installation
height and positioning of power sockets is
adapted to the selected white goods and
building structure.
WALL CABINET/BASE CABINET
Recommended positioning of power
sockets as per the image. When
positioning in fan cabinets, bear in mind
the placement of the connection to the
ventilation duct. The plug should be easily
accessible. When connecting up a dish-
washer, it is recommended that power
and water connections are pulled down
in the dishwasher base cabinet
B. Dimensions
LIGHT FITTINGS
For lighting under wall cabinets, it is
enough to have an electric conduit
coming out under the bottom edge of
the wall cabinet. If you have LED lights,
place the driver in a suitable place,
such as inside or above a cabinet. NB:
Remember that the cabinets are not
set up for cable laying, which means
that any recesses for cables and cable
strips will need to be made on site in
the bottom, shelves and top. Plan
electrical outlets for lighting in advance
on your kitchen drawing together with
an electrician. Many of our wall cabinets
at heights of 700, 850 and 988 mm can
be ordered with grooves for cable laying
(surcharge) on the outside, which are
then hidden by adjacent cabinets or by
a decorative side.
WALL-HUNG EXTRACTOR HOODS
A socket positioned 2200 mm above
floor level is suitable for most wall-hung
extractor hoods. Check with the fan sup-
plier’s instructions for the specific fan.
Built-in micro
Fridge/Freezer
Built-in oven
Power so
ck
et c
c 2000
Base cabinet for hob with
Scala as selected drawer.
*Measurment series refers to
DUO-drawer.
Power so
ck
et c
c 1500 mm (
or 2 p
cs
) built
-in micr
o
Check the position of the power socket when the height of the white goods exceeds 1900 mm above the
floor. Observe the depth of built-in appliances and drawer depth in the frame so that the socket and plug
fit. If necessary, the socket needs to be placed in adjacent space.
Nailing batten
Fan/ Extractor hood
Llighting under cabinets
Hob
Dishwasher
Sink cabinet
Nailing batten
Water and drains may not project
more than 100 mm from the wall.
Output f
or ele
ctric t
ub
es f
or cabinet lighting 14
00
Output f
or ele
ctric t
ub
es f
or e
xtr
ac
tor f
an or e
xtr
ac
tor ho
od 2
200
Oven