![VAT 95248-PAGI-0002 Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/vat/95248-pagi-0002/95248-pagi-0002_installation-operating-and-maintenance-instructions_4129056066.webp)
Installation, Operating & Maintenance Instructions
Series 612 DN 250 (I.D. 10”), EtherCAT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
282408EB
2012-04-23
66/81
4.1 Additional EtherCAT warning
Failure detection with CPA or
CV software
Check
Action
Network failure: No EtherCAT
communication is active
(warning 8)
-
EtherCAT cable ok?
-
Connection to master ok?
-
Process data output
watchdog (SyncManager2)
disabled or timing settings
wrong?
-
Check EtherCAT cable.
-
Check the EtherCAT connection to master.
-
Check the process data output watchdog
–
SyncManager2 settings (see chapter: «EtherCAT
configuration - 5. EtherCAT process data output
watchdog
– SyncManager»).
If you need any further information, please contact one of our service centers. You can find the addresses on our website:
http://www.vat.ch