GENERAL WARNING bitmap table:
Bit
Description
0
SERVICE REQUEST
Valve movement tight
1
LEARN DATA SET
Learn data not present. Learn required for adaptive pressure control.
2
NOT USED (reserved)
-
3
POWER FAILURE
BATTERY
Not ready, voltage too low.
4
SENSOR OVERLAPPING
Sensor deviation between sensor 1 and sensor 2 >= ±10%.
5
ISOLATION VALVE
FAILURE
Position indicator signal(s) of isolation valve are faulty.
6
NOT USED (reserved)
-
7-9
NOT USED (reserved)
-
10
SENSOR
MEASUREMENT UNIT
FAULTY
AD-converter of Sensor input 1 and/or 2 (optional, only in case of 2 sensor version) on the master
board is faulty.
11-15