Installation, Operating & Maintenance Instructions
Series 612 DN 250 (I.D. 10”), EtherCAT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
282408EB
2012-04-23
18/81
2.6.4 Power and sensor connection ( 15 VDC sensors) without optional SPS module
[612 . . - . .
G
. - . . . . / 612 . . - . .
H
. - . . . . versions only]
2.6.4.1
Sensor power wiring via controller
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the 15 VDC sensors at DB
–15 female sensor connector exactly as shown in the drawing above. Do not
connect other pins, that may damage power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor
interlock to prevent valve from moving.
Fuse 1A
Fuse 1A