Installation, Operating & Maintenance Instructions
Series 612 DN 250 (I.D. 10”), EtherCAT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
282408EB
2012-04-23
21/81
2.6.6 Logic I/O connection
This interface allows for remote operation by means of a command set based on the EtherCAT protocol.
In addition there is a digital input and a digital output. Digital input may only be operated by a switch.
Active
digital input
has:
higher priority than EtherCAT
commands
higher priority than Local
commands
Configuration with switch for digital input:
Note:
Do not connect other pins than indicated in the schematics above! Connector type: Binder M8 (99-3363-00-04).