2. Range of pressure and position values (optional)
The «range of pressure and position values» can be adjusted. That means:
For position values, the value for valve position
“CLOSE”
and the valve position
“OPEN”
can be set to a other
ones then the default 0...100’000 is.
For pressure values, the value for physical
0 Volt
and
10 Volt
of the sensor output can be set to other values
then the default 0...1’000’000 is.
The range of pressure and position values
can be configured by ‘Control View’, ‘Control Performance Analyzer’ or
‘Universal Hyper Terminal’.
The
«set-command»
is:
«s:24xxy
to
z»
.
y:
lower scale value
, floating point, entry with a point ‘.’ and ‘-‘ for negative values possible
z:
upper scale value
, floating point, entry with a point ‘.’ and ‘-‘ for negative values possible
xx: signal number in the buffer
xx
Value
Default range
Min/Max range
Default lower
scale value
Default
upper scale
value
Min lower
scale vlaue
Max upper
scale value
00
Pressure
0
1'000’000
-
1'000’000
1'000’000
01
Pressure sensor 1
0
1'000’000
-
1'000’000
1'000’000
02
Pressure sensor 2 (optional, only in
case of 2 sensor version)
0
1'000’000
-
1'000’000
1'000’000
03
Position
0
100'000
-
1'000’000
1'000’000
04
Not used
– reserved
-
-
-
-
05
Cluster valve position
– not used
0
100'000
-
1'000’000
1'000’000
06
Pressure setpoint
0
1'000’000
-
1'000’000
1'000’000
07
Position setpoint
0
100'000
-
1'000’000
1'000’000
08
Not used
– reserved
-
-
-
-
09
Not used
– reserved
-
-
-
-
10
Not used
– reserved
-
-
-
-
11
Cluster valve freeze position
setpoint
– not used
0
100'000
-
1'000’000
1'000’000
The
«get-command»
is:
«i:24xx»
. The answer returns the range
«i:24xxytoz». The xx is the value number, y value is
the current lower scale value of buffer and value z the upper scale value.
The format of y and z has following syntax: _ _ _ _ _ _ _ _._ _ _ _ _