![VAT 95248-PAGI-0002 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/vat/95248-pagi-0002/95248-pagi-0002_installation-operating-and-maintenance-instructions_4129056023.webp)
Installation, Operating & Maintenance Instructions
Series 612 DN 250 (I.D. 10”), EtherCAT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
282408EB
2012-04-23
23/81
2.6.10 Isolation valve control (IVC) connection
This valve is equipped with an interface to control an isolation valve. This allows to control a solenoid to close / open the
isolation valve. Pin 2 is low to open the isolation valve and high to close it. In addition it reads the close / open feedback
from the isolation valve. The connector is located on the side of the control and actuating unit, rectangular to the pipe.
Connector:
Use only screws with 4-40UNC thread for fastening the DB-9 connector!
For more inform
ation see also in chapter: “Interface” commands.